Ionospheric tomography method by reducing grid resolution locally

The construction of the voxel model is an important part of computer ionospheric tomography (CIT) method. It will no doubt affect the accuracy of the CIT method. However, most existing researches focus on how to improve the image’s accuracy via inversion algorithm and few of them are concerned with...

Full description

Bibliographic Details
Main Authors: WANG Wenyue, YU Jieqing, WANG Ying, JIA Chenyi, WU Lixin, ZHANG Shaoliang
Format: Article
Language:zho
Published: Surveying and Mapping Press 2020-07-01
Series:Acta Geodaetica et Cartographica Sinica
Subjects:
Online Access:http://html.rhhz.net/CHXB/html/2020-7-843.htm
id doaj-5a181ea339764027a9a3d9885f10a21d
record_format Article
spelling doaj-5a181ea339764027a9a3d9885f10a21d2020-11-25T03:45:11ZzhoSurveying and Mapping PressActa Geodaetica et Cartographica Sinica1001-15951001-15952020-07-0149784385310.11947/j.AGCS.2020.2019022720200705Ionospheric tomography method by reducing grid resolution locallyWANG Wenyue0YU Jieqing1WANG Ying2JIA Chenyi3WU Lixin4ZHANG Shaoliang5Shool of Environment Science and Spatial Informatics, China University of Mining and Technology, Xuzhou 221116, China;Shool of Environment Science and Spatial Informatics, China University of Mining and Technology, Xuzhou 221116, China;Shool of Environment Science and Spatial Informatics, China University of Mining and Technology, Xuzhou 221116, China;Shool of Environment Science and Spatial Informatics, China University of Mining and Technology, Xuzhou 221116, China;School of Geosciences and Info-Physics, Central South University, Changsha 410083, ChinatShool of Environment Science and Spatial Informatics, China University of Mining and Technology, Xuzhou 221116, China;The construction of the voxel model is an important part of computer ionospheric tomography (CIT) method. It will no doubt affect the accuracy of the CIT method. However, most existing researches focus on how to improve the image’s accuracy via inversion algorithm and few of them are concerned with the grid construction solution. This paper intends to improve accuracy by making some optimization on the voxel model. Some preliminary experiments were first carried out to explore the relationship between the accuracy of the image and its corresponding resolution. Then, based on the findings, a new CIT method, which is to improve the accuracy of the tomographic image of the interesting area at the price of reducing the resolution of the non-interesting area, was proposed. After that, some further experiments were taken to validate the new method. After comparing various accuracy indicators, such as root mean square error (RMSE), absolute mean error (MAE), 68% percentile, 95% percentile and stand deviation, the new method is showed to be better than the one that is not using the method proposed in this paper. According to our experiments, the new method is able to decrease RMSE/MAE of the tomographic image by 15% to 40%.http://html.rhhz.net/CHXB/html/2020-7-843.htmionospheric tomographyvoxel model constructionionospheric imaginggrid resolution
collection DOAJ
language zho
format Article
sources DOAJ
author WANG Wenyue
YU Jieqing
WANG Ying
JIA Chenyi
WU Lixin
ZHANG Shaoliang
spellingShingle WANG Wenyue
YU Jieqing
WANG Ying
JIA Chenyi
WU Lixin
ZHANG Shaoliang
Ionospheric tomography method by reducing grid resolution locally
Acta Geodaetica et Cartographica Sinica
ionospheric tomography
voxel model construction
ionospheric imaging
grid resolution
author_facet WANG Wenyue
YU Jieqing
WANG Ying
JIA Chenyi
WU Lixin
ZHANG Shaoliang
author_sort WANG Wenyue
title Ionospheric tomography method by reducing grid resolution locally
title_short Ionospheric tomography method by reducing grid resolution locally
title_full Ionospheric tomography method by reducing grid resolution locally
title_fullStr Ionospheric tomography method by reducing grid resolution locally
title_full_unstemmed Ionospheric tomography method by reducing grid resolution locally
title_sort ionospheric tomography method by reducing grid resolution locally
publisher Surveying and Mapping Press
series Acta Geodaetica et Cartographica Sinica
issn 1001-1595
1001-1595
publishDate 2020-07-01
description The construction of the voxel model is an important part of computer ionospheric tomography (CIT) method. It will no doubt affect the accuracy of the CIT method. However, most existing researches focus on how to improve the image’s accuracy via inversion algorithm and few of them are concerned with the grid construction solution. This paper intends to improve accuracy by making some optimization on the voxel model. Some preliminary experiments were first carried out to explore the relationship between the accuracy of the image and its corresponding resolution. Then, based on the findings, a new CIT method, which is to improve the accuracy of the tomographic image of the interesting area at the price of reducing the resolution of the non-interesting area, was proposed. After that, some further experiments were taken to validate the new method. After comparing various accuracy indicators, such as root mean square error (RMSE), absolute mean error (MAE), 68% percentile, 95% percentile and stand deviation, the new method is showed to be better than the one that is not using the method proposed in this paper. According to our experiments, the new method is able to decrease RMSE/MAE of the tomographic image by 15% to 40%.
topic ionospheric tomography
voxel model construction
ionospheric imaging
grid resolution
url http://html.rhhz.net/CHXB/html/2020-7-843.htm
work_keys_str_mv AT wangwenyue ionospherictomographymethodbyreducinggridresolutionlocally
AT yujieqing ionospherictomographymethodbyreducinggridresolutionlocally
AT wangying ionospherictomographymethodbyreducinggridresolutionlocally
AT jiachenyi ionospherictomographymethodbyreducinggridresolutionlocally
AT wulixin ionospherictomographymethodbyreducinggridresolutionlocally
AT zhangshaoliang ionospherictomographymethodbyreducinggridresolutionlocally
_version_ 1724510672726786048