Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method

Evaluations of the acidity or alkalinity of solutions are used in many industries such as food industries, medicine, chemical engineering, petrochemical industries, agriculture, animal husbandry, industrial laboratories, etc. Portable and stationary pH measurements are very common and are an integra...

Full description

Bibliographic Details
Main Authors: Hamed Khorami, Somayeh Mahdian, Seyed Salman Zakariaee, Meysam Aziznejad
Format: Article
Language:fas
Published: Ilam University of Medical Sciences 2021-05-01
Series:Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Īlām
Subjects:
ph
Online Access:http://sjimu.medilam.ac.ir/article-1-6915-en.html
id doaj-597ba258b4394fc9956ec518bf45d7e9
record_format Article
spelling doaj-597ba258b4394fc9956ec518bf45d7e92021-10-09T05:48:10Zfas Ilam University of Medical SciencesMajallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Īlām1563-47282588-31352021-05-012921323Design and Construction of an Automatic pH Adjustment System by Instant Feedback MethodHamed Khorami0Somayeh Mahdian1Seyed Salman Zakariaee2Meysam Aziznejad3 Health Technology Incubator Center, Ilam University of Medical Sciences, Ilam, Iran Health Technology Incubator Center, Ilam University of Medical Sciences, Ilam, Iran Health Technology Incubator Center, Ilam University of Medical Sciences, Ilam, Iran Health Technology Incubator Center, Ilam University of Medical Sciences, Ilam, Iran Evaluations of the acidity or alkalinity of solutions are used in many industries such as food industries, medicine, chemical engineering, petrochemical industries, agriculture, animal husbandry, industrial laboratories, etc. Portable and stationary pH measurements are very common and are an integral part of these studies, due to the importance of pH. In most of these evaluations and studies, a solution with the preferred pH magnitude must be prepared. Therefore, it is necessary to have a device that can instantaneously control and reset the pH of the solution. In this study, a pH meter equipped with an automatic pH regulator by instant feedback method is described. This system was designed and constructed to create an automatic pH regulator without manual intervention for toxic and dangerous solutions, which could accurately adjust the desired pH in the shortest possible time. The automatic pH adjustment system is equipped with a pH measuring unit that can instantaneously present the pH of the solution. The user determines the desired pH value and the system decides to use the acid or alkaline reference tanks to reach the target point. These operations can be done in a fully automated or manual manner. The error (tolerance) of the automatic pH adjustment of the solution is 0.02, which is very small in the pH evaluations.http://sjimu.medilam.ac.ir/article-1-6915-en.htmlphph meterautomatic ph adjustment of the solutionph adjustment of the solution by instant feedback method
collection DOAJ
language fas
format Article
sources DOAJ
author Hamed Khorami
Somayeh Mahdian
Seyed Salman Zakariaee
Meysam Aziznejad
spellingShingle Hamed Khorami
Somayeh Mahdian
Seyed Salman Zakariaee
Meysam Aziznejad
Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method
Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Īlām
ph
ph meter
automatic ph adjustment of the solution
ph adjustment of the solution by instant feedback method
author_facet Hamed Khorami
Somayeh Mahdian
Seyed Salman Zakariaee
Meysam Aziznejad
author_sort Hamed Khorami
title Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method
title_short Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method
title_full Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method
title_fullStr Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method
title_full_unstemmed Design and Construction of an Automatic pH Adjustment System by Instant Feedback Method
title_sort design and construction of an automatic ph adjustment system by instant feedback method
publisher Ilam University of Medical Sciences
series Majallah-i Dānishgāh-i ’Ulūm-i Pizishkī-i Īlām
issn 1563-4728
2588-3135
publishDate 2021-05-01
description Evaluations of the acidity or alkalinity of solutions are used in many industries such as food industries, medicine, chemical engineering, petrochemical industries, agriculture, animal husbandry, industrial laboratories, etc. Portable and stationary pH measurements are very common and are an integral part of these studies, due to the importance of pH. In most of these evaluations and studies, a solution with the preferred pH magnitude must be prepared. Therefore, it is necessary to have a device that can instantaneously control and reset the pH of the solution. In this study, a pH meter equipped with an automatic pH regulator by instant feedback method is described. This system was designed and constructed to create an automatic pH regulator without manual intervention for toxic and dangerous solutions, which could accurately adjust the desired pH in the shortest possible time. The automatic pH adjustment system is equipped with a pH measuring unit that can instantaneously present the pH of the solution. The user determines the desired pH value and the system decides to use the acid or alkaline reference tanks to reach the target point. These operations can be done in a fully automated or manual manner. The error (tolerance) of the automatic pH adjustment of the solution is 0.02, which is very small in the pH evaluations.
topic ph
ph meter
automatic ph adjustment of the solution
ph adjustment of the solution by instant feedback method
url http://sjimu.medilam.ac.ir/article-1-6915-en.html
work_keys_str_mv AT hamedkhorami designandconstructionofanautomaticphadjustmentsystembyinstantfeedbackmethod
AT somayehmahdian designandconstructionofanautomaticphadjustmentsystembyinstantfeedbackmethod
AT seyedsalmanzakariaee designandconstructionofanautomaticphadjustmentsystembyinstantfeedbackmethod
AT meysamaziznejad designandconstructionofanautomaticphadjustmentsystembyinstantfeedbackmethod
_version_ 1716830523733573632