The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas

Ash deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried o...

Full description

Bibliographic Details
Main Authors: Lei Ma, Feng-zhong Sun, Zhi-min Li, Pei Chen, Fei Li
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:Discrete Dynamics in Nature and Society
Online Access:http://dx.doi.org/10.1155/2016/8352317
id doaj-596c359530dc44ffb1c891ffc16307ea
record_format Article
spelling doaj-596c359530dc44ffb1c891ffc16307ea2020-11-24T22:54:28ZengHindawi LimitedDiscrete Dynamics in Nature and Society1026-02261607-887X2016-01-01201610.1155/2016/83523178352317The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue GasLei Ma0Feng-zhong Sun1Zhi-min Li2Pei Chen3Fei Li4School of Energy & Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy & Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy & Power Engineering, Shandong University, Jinan 250061, ChinaJinan Institute of Measurement and Testing, Jinan 250002, ChinaCollege of Physics Science & Technology, Jinan University, Jinan 250022, ChinaAsh deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried out with different types of heat exchange tubes in different flue gas environments. In this paper, Nusselt Number Nu and fouling factor ε are calculated to describe the heat transfer characteristics so as to study the ash deposition condition. The scanning electron microscope (SEM) is used for the analysis of ash samples obtained from the outer wall of heat exchange tubes. The dynamic process of ash deposition is studied under different temperatures of outer wall. The results showed that ash deposition of heat exchanger will achieve a stable state in constant flue gas environment. According to the condition of condensation of acid vapor and water vapor, the process of ash deposition can be distinguished as mere ash deposition, acid-ash coupling deposition, and acid-water-ash coupling deposition.http://dx.doi.org/10.1155/2016/8352317
collection DOAJ
language English
format Article
sources DOAJ
author Lei Ma
Feng-zhong Sun
Zhi-min Li
Pei Chen
Fei Li
spellingShingle Lei Ma
Feng-zhong Sun
Zhi-min Li
Pei Chen
Fei Li
The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
Discrete Dynamics in Nature and Society
author_facet Lei Ma
Feng-zhong Sun
Zhi-min Li
Pei Chen
Fei Li
author_sort Lei Ma
title The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
title_short The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
title_full The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
title_fullStr The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
title_full_unstemmed The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
title_sort coupling effect research of ash deposition and condensation in low temperature flue gas
publisher Hindawi Limited
series Discrete Dynamics in Nature and Society
issn 1026-0226
1607-887X
publishDate 2016-01-01
description Ash deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried out with different types of heat exchange tubes in different flue gas environments. In this paper, Nusselt Number Nu and fouling factor ε are calculated to describe the heat transfer characteristics so as to study the ash deposition condition. The scanning electron microscope (SEM) is used for the analysis of ash samples obtained from the outer wall of heat exchange tubes. The dynamic process of ash deposition is studied under different temperatures of outer wall. The results showed that ash deposition of heat exchanger will achieve a stable state in constant flue gas environment. According to the condition of condensation of acid vapor and water vapor, the process of ash deposition can be distinguished as mere ash deposition, acid-ash coupling deposition, and acid-water-ash coupling deposition.
url http://dx.doi.org/10.1155/2016/8352317
work_keys_str_mv AT leima thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT fengzhongsun thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT zhiminli thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT peichen thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT feili thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT leima couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT fengzhongsun couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT zhiminli couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT peichen couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
AT feili couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas
_version_ 1725659592652750848