The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas
Ash deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried o...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | Discrete Dynamics in Nature and Society |
Online Access: | http://dx.doi.org/10.1155/2016/8352317 |
id |
doaj-596c359530dc44ffb1c891ffc16307ea |
---|---|
record_format |
Article |
spelling |
doaj-596c359530dc44ffb1c891ffc16307ea2020-11-24T22:54:28ZengHindawi LimitedDiscrete Dynamics in Nature and Society1026-02261607-887X2016-01-01201610.1155/2016/83523178352317The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue GasLei Ma0Feng-zhong Sun1Zhi-min Li2Pei Chen3Fei Li4School of Energy & Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy & Power Engineering, Shandong University, Jinan 250061, ChinaSchool of Energy & Power Engineering, Shandong University, Jinan 250061, ChinaJinan Institute of Measurement and Testing, Jinan 250002, ChinaCollege of Physics Science & Technology, Jinan University, Jinan 250022, ChinaAsh deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried out with different types of heat exchange tubes in different flue gas environments. In this paper, Nusselt Number Nu and fouling factor ε are calculated to describe the heat transfer characteristics so as to study the ash deposition condition. The scanning electron microscope (SEM) is used for the analysis of ash samples obtained from the outer wall of heat exchange tubes. The dynamic process of ash deposition is studied under different temperatures of outer wall. The results showed that ash deposition of heat exchanger will achieve a stable state in constant flue gas environment. According to the condition of condensation of acid vapor and water vapor, the process of ash deposition can be distinguished as mere ash deposition, acid-ash coupling deposition, and acid-water-ash coupling deposition.http://dx.doi.org/10.1155/2016/8352317 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Lei Ma Feng-zhong Sun Zhi-min Li Pei Chen Fei Li |
spellingShingle |
Lei Ma Feng-zhong Sun Zhi-min Li Pei Chen Fei Li The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas Discrete Dynamics in Nature and Society |
author_facet |
Lei Ma Feng-zhong Sun Zhi-min Li Pei Chen Fei Li |
author_sort |
Lei Ma |
title |
The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas |
title_short |
The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas |
title_full |
The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas |
title_fullStr |
The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas |
title_full_unstemmed |
The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas |
title_sort |
coupling effect research of ash deposition and condensation in low temperature flue gas |
publisher |
Hindawi Limited |
series |
Discrete Dynamics in Nature and Society |
issn |
1026-0226 1607-887X |
publishDate |
2016-01-01 |
description |
Ash deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried out with different types of heat exchange tubes in different flue gas environments. In this paper, Nusselt Number Nu and fouling factor ε are calculated to describe the heat transfer characteristics so as to study the ash deposition condition. The scanning electron microscope (SEM) is used for the analysis of ash samples obtained from the outer wall of heat exchange tubes. The dynamic process of ash deposition is studied under different temperatures of outer wall. The results showed that ash deposition of heat exchanger will achieve a stable state in constant flue gas environment. According to the condition of condensation of acid vapor and water vapor, the process of ash deposition can be distinguished as mere ash deposition, acid-ash coupling deposition, and acid-water-ash coupling deposition. |
url |
http://dx.doi.org/10.1155/2016/8352317 |
work_keys_str_mv |
AT leima thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT fengzhongsun thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT zhiminli thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT peichen thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT feili thecouplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT leima couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT fengzhongsun couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT zhiminli couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT peichen couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas AT feili couplingeffectresearchofashdepositionandcondensationinlowtemperaturefluegas |
_version_ |
1725659592652750848 |