Novel Design of a Usable and Accurate Anthropometric Caliper

Background: Anthropometric kits are extensively used in workstation and product design projects, and with the advancement of technology, they have turned into highly complex and effective instruments. However, there are still many challenging problems in usability and reliability of application of t...

Full description

Bibliographic Details
Main Authors: R Osquei-Zadeh, M Rousta-Nezhad
Format: Article
Language:English
Published: National Iranian Oil Company (NIOC) Health Organization 2012-06-01
Series:The International Journal of Occupational and Environmental Medicine
Subjects:
Online Access:http://www.theijoem.com/ijoem/index.php/ijoem/article/view/148
id doaj-5952c89d26ba4c09b1a772e3ad07441b
record_format Article
spelling doaj-5952c89d26ba4c09b1a772e3ad07441b2020-11-25T01:39:04ZengNational Iranian Oil Company (NIOC) Health OrganizationThe International Journal of Occupational and Environmental Medicine2008-65202008-68142012-06-013312635105Novel Design of a Usable and Accurate Anthropometric CaliperR Osquei-Zadeh0M Rousta-Nezhad1University of Social Welfare and Rehabilitation Sciences, TehranUniversity of Social Welfare and Rehabilitation Sciences, TehranBackground: Anthropometric kits are extensively used in workstation and product design projects, and with the advancement of technology, they have turned into highly complex and effective instruments. However, there are still many challenging problems in usability and reliability of application of these kits in real-world settings. Objectives: To identify the usability and accuracy issues with a conventional anthropometric caliper, and to propose measurable design features to enhance the functionality of the caliper. Methods: The measurement process using a conventional anthropometric caliper was systematically analyzed through detailed hierarchical task analyses. Also, six qualified anthropometry specialists performed heuristic evaluations to gain valuable insights into major usability issues in relation to the existing body measurement devices. Based on the resulting concepts, a mock-up was developed and evaluated against the desired specifications. Results: Incorrect positioning angle of the caliper, as well as applying various amounts of force by different investigators to push the caliper branches against body parts, appeared to be the main factors introducing inaccuracy to anthropometric data. Installing a spirit level on caliper, and also a pre-programmed microprocessor for real-time saving of the obtained data, facilitated the measurement process for both investigators and subjects. Conclusion: Accuracy, followed by usability is the primary concern in designing anthropometric instruments. However, expectations would vary from one specialist to another. Therefore, trade-offs should be made when incorporating innovative features in novel designed body measurement kits.http://www.theijoem.com/ijoem/index.php/ijoem/article/view/148AnthropometryUsabilityAccuracyHierarchical task analysisHeuristic evaluation
collection DOAJ
language English
format Article
sources DOAJ
author R Osquei-Zadeh
M Rousta-Nezhad
spellingShingle R Osquei-Zadeh
M Rousta-Nezhad
Novel Design of a Usable and Accurate Anthropometric Caliper
The International Journal of Occupational and Environmental Medicine
Anthropometry
Usability
Accuracy
Hierarchical task analysis
Heuristic evaluation
author_facet R Osquei-Zadeh
M Rousta-Nezhad
author_sort R Osquei-Zadeh
title Novel Design of a Usable and Accurate Anthropometric Caliper
title_short Novel Design of a Usable and Accurate Anthropometric Caliper
title_full Novel Design of a Usable and Accurate Anthropometric Caliper
title_fullStr Novel Design of a Usable and Accurate Anthropometric Caliper
title_full_unstemmed Novel Design of a Usable and Accurate Anthropometric Caliper
title_sort novel design of a usable and accurate anthropometric caliper
publisher National Iranian Oil Company (NIOC) Health Organization
series The International Journal of Occupational and Environmental Medicine
issn 2008-6520
2008-6814
publishDate 2012-06-01
description Background: Anthropometric kits are extensively used in workstation and product design projects, and with the advancement of technology, they have turned into highly complex and effective instruments. However, there are still many challenging problems in usability and reliability of application of these kits in real-world settings. Objectives: To identify the usability and accuracy issues with a conventional anthropometric caliper, and to propose measurable design features to enhance the functionality of the caliper. Methods: The measurement process using a conventional anthropometric caliper was systematically analyzed through detailed hierarchical task analyses. Also, six qualified anthropometry specialists performed heuristic evaluations to gain valuable insights into major usability issues in relation to the existing body measurement devices. Based on the resulting concepts, a mock-up was developed and evaluated against the desired specifications. Results: Incorrect positioning angle of the caliper, as well as applying various amounts of force by different investigators to push the caliper branches against body parts, appeared to be the main factors introducing inaccuracy to anthropometric data. Installing a spirit level on caliper, and also a pre-programmed microprocessor for real-time saving of the obtained data, facilitated the measurement process for both investigators and subjects. Conclusion: Accuracy, followed by usability is the primary concern in designing anthropometric instruments. However, expectations would vary from one specialist to another. Therefore, trade-offs should be made when incorporating innovative features in novel designed body measurement kits.
topic Anthropometry
Usability
Accuracy
Hierarchical task analysis
Heuristic evaluation
url http://www.theijoem.com/ijoem/index.php/ijoem/article/view/148
work_keys_str_mv AT rosqueizadeh noveldesignofausableandaccurateanthropometriccaliper
AT mroustanezhad noveldesignofausableandaccurateanthropometriccaliper
_version_ 1725050568201732096