Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar

The different types of defects of half grouting sleeves will remarkably increase the risks of precast concrete structures. In order to better understand the defects of rebar connections between half grouting sleeves, six different test groups on insufficient grout height, insufficient compactness, r...

Full description

Bibliographic Details
Main Authors: Hong Guo, Jiaxin Zhang, Changwei Wang
Format: Article
Language:English
Published: Hindawi Limited 2020-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2020/5389861
id doaj-594b1c44f8ff41f5bdc4de891eb2f11b
record_format Article
spelling doaj-594b1c44f8ff41f5bdc4de891eb2f11b2020-11-25T03:14:56ZengHindawi LimitedAdvances in Civil Engineering1687-80861687-80942020-01-01202010.1155/2020/53898615389861Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of RebarHong Guo0Jiaxin Zhang1Changwei Wang2Civil Engineering, North University of China, Taiyuan, Shanxi, ChinaCivil Engineering, North University of China, Taiyuan, Shanxi, ChinaChina Shanxi Sijian Group Co., Ltd., Taiyuan, Shanxi, ChinaThe different types of defects of half grouting sleeves will remarkably increase the risks of precast concrete structures. In order to better understand the defects of rebar connections between half grouting sleeves, six different test groups on insufficient grout height, insufficient compactness, rebar offset, insufficient rebar anchor length, overtime grouting, and control group had been researched. The uniaxial tension experiments were conducted for the 24 different specimens, and load-slip curves were also analyzed. The results of the experiments showed that the outside of the rebar was snapped off as for the destruction mode, while the destruction mode changed as the increment of the degree of defect surpasses the critical value. The bearing capacity and deformability were dropped with the increase in the degree of defects, and a critical value of rebar anchoring length of sleeve was discovered. In the end, different finite-element models were built based on different deficient situations, and load-slip constitutive model was obtained, which would be helpful to evaluate the structural performance of precast concrete structures in construction.http://dx.doi.org/10.1155/2020/5389861
collection DOAJ
language English
format Article
sources DOAJ
author Hong Guo
Jiaxin Zhang
Changwei Wang
spellingShingle Hong Guo
Jiaxin Zhang
Changwei Wang
Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar
Advances in Civil Engineering
author_facet Hong Guo
Jiaxin Zhang
Changwei Wang
author_sort Hong Guo
title Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar
title_short Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar
title_full Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar
title_fullStr Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar
title_full_unstemmed Experimental Study on Influence of Connection Defects on Joint Strength of Half-Grouted Sleeve Splicing of Rebar
title_sort experimental study on influence of connection defects on joint strength of half-grouted sleeve splicing of rebar
publisher Hindawi Limited
series Advances in Civil Engineering
issn 1687-8086
1687-8094
publishDate 2020-01-01
description The different types of defects of half grouting sleeves will remarkably increase the risks of precast concrete structures. In order to better understand the defects of rebar connections between half grouting sleeves, six different test groups on insufficient grout height, insufficient compactness, rebar offset, insufficient rebar anchor length, overtime grouting, and control group had been researched. The uniaxial tension experiments were conducted for the 24 different specimens, and load-slip curves were also analyzed. The results of the experiments showed that the outside of the rebar was snapped off as for the destruction mode, while the destruction mode changed as the increment of the degree of defect surpasses the critical value. The bearing capacity and deformability were dropped with the increase in the degree of defects, and a critical value of rebar anchoring length of sleeve was discovered. In the end, different finite-element models were built based on different deficient situations, and load-slip constitutive model was obtained, which would be helpful to evaluate the structural performance of precast concrete structures in construction.
url http://dx.doi.org/10.1155/2020/5389861
work_keys_str_mv AT hongguo experimentalstudyoninfluenceofconnectiondefectsonjointstrengthofhalfgroutedsleevesplicingofrebar
AT jiaxinzhang experimentalstudyoninfluenceofconnectiondefectsonjointstrengthofhalfgroutedsleevesplicingofrebar
AT changweiwang experimentalstudyoninfluenceofconnectiondefectsonjointstrengthofhalfgroutedsleevesplicingofrebar
_version_ 1715268374118793216