Odor Characteristics and Concentration of Malodorous Chemical Compounds Emitted from a Combined Sewer System in Korea

(1) Objectives: This study was carried out to investigate the characteristics of odors emitted from a combined sewer for the abatement of combined sewer odor. (2) Methods: The odor samples emitted from the combined sewer were collected at 14 sites, and the concentrations of 13 malodorous chemicals w...

Full description

Bibliographic Details
Main Author: Sangjin Park
Format: Article
Language:English
Published: MDPI AG 2020-06-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/11/6/667
Description
Summary:(1) Objectives: This study was carried out to investigate the characteristics of odors emitted from a combined sewer for the abatement of combined sewer odor. (2) Methods: The odor samples emitted from the combined sewer were collected at 14 sites, and the concentrations of 13 malodorous chemicals were determined by the instrumental analysis such as gas chromatography. To understand the sensory characteristic of the combined sewer odor, the on-site odor intensity (OOI) was evaluated by the direct sensory method using the human olfactory sensitivity of panelists with a normal sense of smell. The primary odor-causing compounds with high contribution were evaluated based on the converted odor concentration (COC), which was calculated by using the compound concentration and threshold limit value. Since the direct sensory method requires a lot of manpower and time, the converted odor intensity method (COI) calculated by the malodorous compound concentration was reviewed and compared with other cases. (3) Results: As a result of the instrumental analysis, four compounds which were higher than other compounds, showed an average of 325 ppb for H<sub>2</sub>S, 121 ppb for NH<sub>3</sub>, 102 ppb for CH<sub>3</sub>SH, and 108 ppb for toluene. The rest of the compounds appeared low, below 60 ppb. Based on the result of evaluating the COC, three compounds which are H<sub>2</sub>S, CH<sub>3</sub>SH, and (CH<sub>3</sub>)<sub>3</sub>N appeared to be compounds with a high contribution to combined sewer odor. Especially, it was estimated that H<sub>2</sub>S was the main odor-causing compound in this study. The on-site odor intensity of the combined sewer as judged by 5 panelists appeared to be 2.8 degrees on average, the same as COI. The correlation between the odor intensity and the H<sub>2</sub>S concentration in the combined sewer showed as the following equation: COI, degree = 1.0757 × log (H<sub>2</sub>S conc., ppb) + 0.3696. (4) Conclusions: In Korea, the odor emission standard in the atmosphere including sewer odor has adopted 20 ppb for H<sub>2</sub>S, and less than 2 degrees for odor intensity in the non-industrial area. However, since the mean observed odor intensity was 2.8 degrees and the concentration of H<sub>2</sub>S was also 325 ppb on average in this study, it was concluded that countermeasures should be prepared to reduce the complaints due to combined sewer odor in residential areas.
ISSN:2073-4433