The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system
The numerical investigations of unsteady heat transfer in the seasonal heat accumulator of a solar plant system with the 9 ground heat exchangers in process of periodic, with day cycle, charging at the summer period are carried out. Heat exchanger is a vertical sonde with the coaxial tubs. The mathe...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Odessa National Polytechnic University
2015-06-01
|
Series: | Trudy Odesskogo Politehničeskogo Universiteta |
Subjects: | |
Online Access: | http://pratsi.opu.ua/articles/show/1595 |
id |
doaj-5865a03cbf404b88b66c20aa71cd152d |
---|---|
record_format |
Article |
spelling |
doaj-5865a03cbf404b88b66c20aa71cd152d2020-11-24T22:44:49ZengOdessa National Polytechnic UniversityTrudy Odesskogo Politehničeskogo Universiteta2076-24292223-38142015-06-0120152929610.15276/opu.2.46.2015.17The conditions of twenty-four—hour charging of the group ground accumulator of solar plant systemViktor V. Wysochin0Ye. I. Kozhukhar1Odessa National Polytechnic UniversityOdessa National Polytechnic UniversityThe numerical investigations of unsteady heat transfer in the seasonal heat accumulator of a solar plant system with the 9 ground heat exchangers in process of periodic, with day cycle, charging at the summer period are carried out. Heat exchanger is a vertical sonde with the coaxial tubs. The mathematical model of conjugate operation of the solar plant system and the ground heat exchangers encloses differential equations, that of the conditions of incoming and converting the solar energy in the heliocollectors describe, and heat exchange in the ground heat exchangers and in the array of ground too. The necessity to take account of reciprocal effect of dimensions of the heliocollectors and the ground heat exchanger it is shown, and possibility of increase of effectiveness of the accumulator, which have operate with inside circulation heatcarrier by night too. The functioning recommendations of the heat exchangers of accumulator are introduced.http://pratsi.opu.ua/articles/show/1595ground heat exchangerseasonal group heat accumulatorsolar plant system |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Viktor V. Wysochin Ye. I. Kozhukhar |
spellingShingle |
Viktor V. Wysochin Ye. I. Kozhukhar The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system Trudy Odesskogo Politehničeskogo Universiteta ground heat exchanger seasonal group heat accumulator solar plant system |
author_facet |
Viktor V. Wysochin Ye. I. Kozhukhar |
author_sort |
Viktor V. Wysochin |
title |
The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system |
title_short |
The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system |
title_full |
The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system |
title_fullStr |
The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system |
title_full_unstemmed |
The conditions of twenty-four—hour charging of the group ground accumulator of solar plant system |
title_sort |
conditions of twenty-four—hour charging of the group ground accumulator of solar plant system |
publisher |
Odessa National Polytechnic University |
series |
Trudy Odesskogo Politehničeskogo Universiteta |
issn |
2076-2429 2223-3814 |
publishDate |
2015-06-01 |
description |
The numerical investigations of unsteady heat transfer in the seasonal heat accumulator of a solar plant system with the 9 ground heat exchangers in process of periodic, with day cycle, charging at the summer period are carried out. Heat exchanger is a vertical sonde with the coaxial tubs. The mathematical model of conjugate operation of the solar plant system and the ground heat exchangers encloses differential equations, that of the conditions of incoming and converting the solar energy in the heliocollectors describe, and heat exchange in the ground heat exchangers and in the array of ground too. The necessity to take account of reciprocal effect of dimensions of the heliocollectors and the ground heat exchanger it is shown, and possibility of increase of effectiveness of the accumulator, which have operate with inside circulation heatcarrier by night too. The functioning recommendations of the heat exchangers of accumulator are introduced. |
topic |
ground heat exchanger seasonal group heat accumulator solar plant system |
url |
http://pratsi.opu.ua/articles/show/1595 |
work_keys_str_mv |
AT viktorvwysochin theconditionsoftwentyfourhourchargingofthegroupgroundaccumulatorofsolarplantsystem AT yeikozhukhar theconditionsoftwentyfourhourchargingofthegroupgroundaccumulatorofsolarplantsystem AT viktorvwysochin conditionsoftwentyfourhourchargingofthegroupgroundaccumulatorofsolarplantsystem AT yeikozhukhar conditionsoftwentyfourhourchargingofthegroupgroundaccumulatorofsolarplantsystem |
_version_ |
1725690279784087552 |