FEA Analysis of Neck Sparing Versus Conventional Cementless Stem
Finite element analysis is a valuable tool in prosthetic design and helps predict specific mechanical behaviors between mechanical testing and clinical observations1. We have studied the effect of tensile stresses of both conventional length stems with conventional neck resections and compared them...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Joint Implant Surgery & Research Foundation
2011-10-01
|
Series: | Reconstructive Review |
Online Access: | https://reconstructivereview.org/ojs/index.php/rr/article/view/2 |
id |
doaj-5861d1a5bc684f17bb64c9206f6e7cea |
---|---|
record_format |
Article |
spelling |
doaj-5861d1a5bc684f17bb64c9206f6e7cea2020-11-25T01:27:06ZengJoint Implant Surgery & Research FoundationReconstructive Review2331-22622331-22702011-10-011110.15438/rr.v1i1.2FEA Analysis of Neck Sparing Versus Conventional Cementless StemDeclan Brazil, PhDTimothy McTighe, Dr. H.S. (hc)Finite element analysis is a valuable tool in prosthetic design and helps predict specific mechanical behaviors between mechanical testing and clinical observations1. We have studied the effect of tensile stresses of both conventional length stems with conventional neck resections and compared them to a novel short curved neck sparing tissue preserving stem design and have found correlation between FEA modeling and plain radiographics. Neck sparing stem with a novel conical flair does improve bio-mechanical conditions in THA as compared to conventional length cementless stems. https://reconstructivereview.org/ojs/index.php/rr/article/view/2 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Declan Brazil, PhD Timothy McTighe, Dr. H.S. (hc) |
spellingShingle |
Declan Brazil, PhD Timothy McTighe, Dr. H.S. (hc) FEA Analysis of Neck Sparing Versus Conventional Cementless Stem Reconstructive Review |
author_facet |
Declan Brazil, PhD Timothy McTighe, Dr. H.S. (hc) |
author_sort |
Declan Brazil, PhD |
title |
FEA Analysis of Neck Sparing Versus Conventional Cementless Stem |
title_short |
FEA Analysis of Neck Sparing Versus Conventional Cementless Stem |
title_full |
FEA Analysis of Neck Sparing Versus Conventional Cementless Stem |
title_fullStr |
FEA Analysis of Neck Sparing Versus Conventional Cementless Stem |
title_full_unstemmed |
FEA Analysis of Neck Sparing Versus Conventional Cementless Stem |
title_sort |
fea analysis of neck sparing versus conventional cementless stem |
publisher |
Joint Implant Surgery & Research Foundation |
series |
Reconstructive Review |
issn |
2331-2262 2331-2270 |
publishDate |
2011-10-01 |
description |
Finite element analysis is a valuable tool in prosthetic design and helps predict specific mechanical behaviors between mechanical testing and clinical observations1. We have studied the effect of tensile stresses of both conventional length stems with conventional neck resections and compared them to a novel short curved neck sparing tissue preserving stem design and have found correlation between FEA modeling and plain radiographics. Neck sparing stem with a novel conical flair does improve bio-mechanical conditions in THA as compared to conventional length cementless stems.
|
url |
https://reconstructivereview.org/ojs/index.php/rr/article/view/2 |
work_keys_str_mv |
AT declanbrazilphd feaanalysisofnecksparingversusconventionalcementlessstem AT timothymctighedrhshc feaanalysisofnecksparingversusconventionalcementlessstem |
_version_ |
1725107040522600448 |