Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate

Abstract Background Application of an endorectal coil (ERC) for 3.0-T prostate magnetic resonance imaging (MRI) is contentious. We hypothesised that a multicoil phased-array protocol provides T2-weighted images (T2WI) and diffusion-weighted images (DWI) with reduced field-of-view (DWIreduced) and mo...

Full description

Bibliographic Details
Main Authors: Sophie Murer, Juergen Scheidler, Ulrike L. Mueller-Lisse, Marissa Helling, Michael Scherr, Ullrich G. Mueller-Lisse
Format: Article
Language:English
Published: SpringerOpen 2019-08-01
Series:European Radiology Experimental
Subjects:
Online Access:http://link.springer.com/article/10.1186/s41747-019-0111-8
Description
Summary:Abstract Background Application of an endorectal coil (ERC) for 3.0-T prostate magnetic resonance imaging (MRI) is contentious. We hypothesised that a multicoil phased-array protocol provides T2-weighted images (T2WI) and diffusion-weighted images (DWI) with reduced field-of-view (DWIreduced) and monoexponential apparent diffusion coefficient (ADC) maps that are technically equivalent with ERC or without ERC (noERC). Methods Axial T2WI (repetition time [TR] 7500 ms, echo time [TE] 98–101 ms) and DWIreduced (field-of-view 149–179 × 71–73 mm2, TR/TE 4500–5500/61–74 ms, b values, 50/800 s/mm2) ERC and noERC images were obtained on identical clinical 3.0-T scanners at two centres and compared for signal-to-noise ratio (SNR) in anterior and posterior outer pericarp (OP) and peripheral placenta (PP) in five green Hayward kiwifruit (Actinidia deliciosa, European Union regulation 543/2011 class 2). Corroboration in 21 patients with benign prostate hyperplasia (negative biopsy, prostate imaging reporting and data system version 2 ≤ 2) involved identical MRI protocols: 10 at site 1, noERC, and 11 at site 2, with ERC. Two-tailed Student’s t test was used. Results With few exceptions, signal-to-noise ratio (SNR) was similar in kiwifruits and prostates for ERC and noERC. In T2WI, SNR was higher posteriorly in noERC MRI for peripheral zone (PZ) (p < 0.001). In DWIreduced, SNR was higher posteriorly in ERC-OP (p = 0.013) and ERC-PZ (p = 0.026) for b = 50 s/mm2; noERC-OP (p = 0.044) and ERC-PZ (p = 0.001) for b = 800 s/mm2; and ERC-OP (p = 0.001), noERC-OP (p = 0.001), and ERC-PZ (p = 0.001) for ADC, respectively. Volumes of kiwifruits and prostates were similar (89.2 ± 11.2 versus 90.8 ± 48.5 cm3, p = 0.638–0.920). Conclusions Findings imply that multicoil phased-array 3.0-T prostate MRI with T2WI and DWIreduced with ADC maps provides equivalent results with and without ERC.
ISSN:2509-9280