Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements
Glass pH electrodes are still successfully applied in the chemical and environmental industry. During their long-term use, periodic calibration is required to maintain the required accuracy of measurements because the parameters of the electrodes change over time. This work presents an aging of 11 p...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-11-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/18/12/4102 |
id |
doaj-57ed3d2b0f3543f59e4ae39a2d18a296 |
---|---|
record_format |
Article |
spelling |
doaj-57ed3d2b0f3543f59e4ae39a2d18a2962020-11-24T23:44:27ZengMDPI AGSensors1424-82202018-11-011812410210.3390/s18124102s18124102Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of MeasurementsAlicja Wiora0Józef Wiora1Institute of Automatic Control, Silesian University of Technology, ul. Akademicka 16, 44-100 Gliwice, PolandInstitute of Automatic Control, Silesian University of Technology, ul. Akademicka 16, 44-100 Gliwice, PolandGlass pH electrodes are still successfully applied in the chemical and environmental industry. During their long-term use, periodic calibration is required to maintain the required accuracy of measurements because the parameters of the electrodes change over time. This work presents an aging of 11 pH electrodes within approximately 600 days in tap water. During this period, potentials of all electrodes in five buffer solutions were measured 44 times. This allowed determining the aging models of the electrodes. Models in other mediums might be different. Changes in slope, standard potential, hysteresis, and linearity of the characteristics were the objects of observations. A method for predicting electrode parameters is proposed. Furthermore, the procedure for estimating the uncertainty of pH measurements considering the aging of the electrodes is described. As a result of this work, a model of the aging process of pH electrodes in tap water can be constructed and subsequently, the measurement accuracy in the periods between calibrations can be improved.https://www.mdpi.com/1424-8220/18/12/4102pH measurementglass electrodelong-term stabilitypredictionhysteresismeasurement uncertainty |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Alicja Wiora Józef Wiora |
spellingShingle |
Alicja Wiora Józef Wiora Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements Sensors pH measurement glass electrode long-term stability prediction hysteresis measurement uncertainty |
author_facet |
Alicja Wiora Józef Wiora |
author_sort |
Alicja Wiora |
title |
Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements |
title_short |
Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements |
title_full |
Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements |
title_fullStr |
Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements |
title_full_unstemmed |
Over One-Year Long-Term Laboratory Tests of pH Electrodes in Terms of Industrial Applications Checking Stabilities of Their Parameters and Their Influence on Uncertainties of Measurements |
title_sort |
over one-year long-term laboratory tests of ph electrodes in terms of industrial applications checking stabilities of their parameters and their influence on uncertainties of measurements |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2018-11-01 |
description |
Glass pH electrodes are still successfully applied in the chemical and environmental industry. During their long-term use, periodic calibration is required to maintain the required accuracy of measurements because the parameters of the electrodes change over time. This work presents an aging of 11 pH electrodes within approximately 600 days in tap water. During this period, potentials of all electrodes in five buffer solutions were measured 44 times. This allowed determining the aging models of the electrodes. Models in other mediums might be different. Changes in slope, standard potential, hysteresis, and linearity of the characteristics were the objects of observations. A method for predicting electrode parameters is proposed. Furthermore, the procedure for estimating the uncertainty of pH measurements considering the aging of the electrodes is described. As a result of this work, a model of the aging process of pH electrodes in tap water can be constructed and subsequently, the measurement accuracy in the periods between calibrations can be improved. |
topic |
pH measurement glass electrode long-term stability prediction hysteresis measurement uncertainty |
url |
https://www.mdpi.com/1424-8220/18/12/4102 |
work_keys_str_mv |
AT alicjawiora overoneyearlongtermlaboratorytestsofphelectrodesintermsofindustrialapplicationscheckingstabilitiesoftheirparametersandtheirinfluenceonuncertaintiesofmeasurements AT jozefwiora overoneyearlongtermlaboratorytestsofphelectrodesintermsofindustrialapplicationscheckingstabilitiesoftheirparametersandtheirinfluenceonuncertaintiesofmeasurements |
_version_ |
1725498355689193472 |