Open circuit mouthpiece ventilation: Concise clinical review

In 2013 new âmouthpiece ventilationâ modes are being introduced to commercially available portable ventilators. Despite this, there is little knowledge of how to use noninvasive intermittent positive pressure ventilation (NIV) as opposed to bi-level positive airway pressure (PAP) and both have almos...

Full description

Bibliographic Details
Main Authors: G. Garuti, A. Nicolini, B. Grecchi, M. Lusuardi, J.C. Winck, J.R. Bach
Format: Article
Language:English
Published: Elsevier 2014-07-01
Series:Revista Portuguesa de Pneumologia
Online Access:http://www.sciencedirect.com/science/article/pii/S087321591400049X
id doaj-57d3ec8242334bbca7468714fde05502
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author G. Garuti
A. Nicolini
B. Grecchi
M. Lusuardi
J.C. Winck
J.R. Bach
spellingShingle G. Garuti
A. Nicolini
B. Grecchi
M. Lusuardi
J.C. Winck
J.R. Bach
Open circuit mouthpiece ventilation: Concise clinical review
Revista Portuguesa de Pneumologia
author_facet G. Garuti
A. Nicolini
B. Grecchi
M. Lusuardi
J.C. Winck
J.R. Bach
author_sort G. Garuti
title Open circuit mouthpiece ventilation: Concise clinical review
title_short Open circuit mouthpiece ventilation: Concise clinical review
title_full Open circuit mouthpiece ventilation: Concise clinical review
title_fullStr Open circuit mouthpiece ventilation: Concise clinical review
title_full_unstemmed Open circuit mouthpiece ventilation: Concise clinical review
title_sort open circuit mouthpiece ventilation: concise clinical review
publisher Elsevier
series Revista Portuguesa de Pneumologia
issn 0873-2159
publishDate 2014-07-01
description In 2013 new âmouthpiece ventilationâ modes are being introduced to commercially available portable ventilators. Despite this, there is little knowledge of how to use noninvasive intermittent positive pressure ventilation (NIV) as opposed to bi-level positive airway pressure (PAP) and both have almost exclusively been reported to have been used via nasal or oro-nasal interfaces rather than via a simple mouthpiece.Non-invasive ventilation is often reported as failing because of airway secretion encumbrance, because of hypercapnia due to inadequate bi-level PAP settings, or poor interface tolerance. The latter can be caused by factors such as excessive pressure on the face from poor fit, excessive oral air leak, anxiety, claustrophobia, and patient-ventilator dys-synchrony. Thus, the interface plays a crucial role in tolerance and effectiveness. Interfaces that cover the nose and/or nose and mouth (oro-nasal) are the most commonly used but are more likely to cause skin breakdown and claustrophobia. Most associated drawbacks can be avoided by using mouthpiece NIV. Open-circuit mouthpiece NIV is being used by large populations in some centers for daytime ventilatory support and complements nocturnal NIV via âmaskâ interfaces for nocturnal ventilatory support. Mouthpiece NIV is also being used for sleep with the mouthpiece fixed in place by a lip-covering flange. Small 15 and 22 mm angled mouthpieces and straw-type mouthpieces are the most commonly used.NIV via mouthpiece is being used as an effective alternative to ventilatory support via tracheostomy tube (TMV) and is associated with a reduced risk of pneumonias and other respiratory complications. Its use facilitates âair-stackingâ to improve cough, speech, and pulmonary compliance, all of which better maintain quality of life for patients with neuromuscular diseases (NMDs) than the invasive alternatives. Considering these benefits and the new availability of mouthpiece ventilator modes, wider knowledge of this technique is now warranted. This review highlights the indications, techniques, advantages and disadvantages of mouthpiece NIV. Resumo: Em 2013, foram introduzidos novos modos de «ventilação por peça bucal», para ventiladores portáteis disponíveis comercialmente. Apesar disto, há pouco conhecimento sobre como usar a ventilação não invasiva por pressão positiva intermitente (NIV) em oposição à pressão positiva bi-nível (PAP) e ambas têm sido referidas, quase exclusivamente, como sendo utilizadas através de interfaces nasais ou oro-nasais, em vez de através de uma simples peça bucal.à referido com frequência a falência da ventilação não invasiva, devido à acumulação de secreções nas vias respiratórias, devido à hipercapnia por deficiente ajuste dos parâmetros da PAP ou devido a uma reduzida tolerância à interface. Esta última pode ser causada por fatores como pressão excessiva na face devido a um ajuste defeituoso, fuga excessiva de ar pela boca, ansiedade, claustrofobia e falta de sincronia entre o doente e o ventilador. Deste modo, a interface tem um papel crucial na tolerância e eficácia. Interfaces que cobrem o nariz e/ou a boca (oro-nasal) são as mais habitualmente usadas, mas são as que apresentam maior propensão a provocarem lesões na pele e claustrofobia. A maioria dos inconvenientes associados pode ser evitada usando VNI por bocal. A VNI de circuito aberto por peça bucal está a ser usada por um número significativo de doentes em alguns centros, na assistência ventilatória diurna e como complemento da VNI noturna através de «máscara». A VNI por peça bucal é igualmente utilizada durante o sono com o bucal fixo na posição, através de uma orla de cobertura do lábio. As peças bucais mais utilizadas são as pequenas anguladas de 15 e 22 mm e as de tipo «palhinha».A VNI através de de peça bucal é usada por um número significativo de doentes como uma alternativa eficaz à ventilação assistida através de tubo de traqueostomia (VTM) e está associada à redução do risco de pneumonias e outras complicações respiratórias. A sua utilização facilita a «acumulação de ar» que aumenta a eficácia da tosse, o discurso e a compliance pulmonar, melhorando a qualidade de vida dos doentes com doenças neuromusculares (DNM) em comparação as alternativas invasivas. Considerando estes benefícios e a disponibilização de modos ventilatórios NIV por peça bucal, é agora garantido um maior conhecimento desta técnica. Esta revisão destaca as indicações, técnicas, vantagens e desvantagens do VNI por peça bucal. Keywords: Noninvasive ventilation, Mouthpiece, Open-circuit mouthpiece ventilation, Neuromuscular disease, Ventilator settings, Palavras-chave: Ventilação não invasiva, Peça Bucal, Ventilação por peça bucal de circuito aberto, Doença neuromuscular, Parâmetros do ventilador
url http://www.sciencedirect.com/science/article/pii/S087321591400049X
work_keys_str_mv AT ggaruti opencircuitmouthpieceventilationconciseclinicalreview
AT anicolini opencircuitmouthpieceventilationconciseclinicalreview
AT bgrecchi opencircuitmouthpieceventilationconciseclinicalreview
AT mlusuardi opencircuitmouthpieceventilationconciseclinicalreview
AT jcwinck opencircuitmouthpieceventilationconciseclinicalreview
AT jrbach opencircuitmouthpieceventilationconciseclinicalreview
_version_ 1725519607924523008
spelling doaj-57d3ec8242334bbca7468714fde055022020-11-24T23:37:33ZengElsevierRevista Portuguesa de Pneumologia0873-21592014-07-01204211218Open circuit mouthpiece ventilation: Concise clinical reviewG. Garuti0A. Nicolini1B. Grecchi2M. Lusuardi3J.C. Winck4J.R. Bach5Respiratory Rehabilitation Unit, San Sebastiano Hospital, Correggio, Reggio Emilia, Italy; Corresponding author.Respiratory Medicine Unit, General Hospital of Sestri Levante, ItalyPhysical Medicine and Rehabilitation Department, ASL4 Chiavarese, ItalyRespiratory Rehabilitation Unit, San Sebastiano Hospital, Correggio, Reggio Emilia, ItalyGlobal Medical Director REMEO, Linde Healthcare, Pullach, GermanyRutgers-New Jersey Medical School, University Hospital, Newark, NJ, USAIn 2013 new âmouthpiece ventilationâ modes are being introduced to commercially available portable ventilators. Despite this, there is little knowledge of how to use noninvasive intermittent positive pressure ventilation (NIV) as opposed to bi-level positive airway pressure (PAP) and both have almost exclusively been reported to have been used via nasal or oro-nasal interfaces rather than via a simple mouthpiece.Non-invasive ventilation is often reported as failing because of airway secretion encumbrance, because of hypercapnia due to inadequate bi-level PAP settings, or poor interface tolerance. The latter can be caused by factors such as excessive pressure on the face from poor fit, excessive oral air leak, anxiety, claustrophobia, and patient-ventilator dys-synchrony. Thus, the interface plays a crucial role in tolerance and effectiveness. Interfaces that cover the nose and/or nose and mouth (oro-nasal) are the most commonly used but are more likely to cause skin breakdown and claustrophobia. Most associated drawbacks can be avoided by using mouthpiece NIV. Open-circuit mouthpiece NIV is being used by large populations in some centers for daytime ventilatory support and complements nocturnal NIV via âmaskâ interfaces for nocturnal ventilatory support. Mouthpiece NIV is also being used for sleep with the mouthpiece fixed in place by a lip-covering flange. Small 15 and 22 mm angled mouthpieces and straw-type mouthpieces are the most commonly used.NIV via mouthpiece is being used as an effective alternative to ventilatory support via tracheostomy tube (TMV) and is associated with a reduced risk of pneumonias and other respiratory complications. Its use facilitates âair-stackingâ to improve cough, speech, and pulmonary compliance, all of which better maintain quality of life for patients with neuromuscular diseases (NMDs) than the invasive alternatives. Considering these benefits and the new availability of mouthpiece ventilator modes, wider knowledge of this technique is now warranted. This review highlights the indications, techniques, advantages and disadvantages of mouthpiece NIV. Resumo: Em 2013, foram introduzidos novos modos de «ventilação por peça bucal», para ventiladores portáteis disponíveis comercialmente. Apesar disto, há pouco conhecimento sobre como usar a ventilação não invasiva por pressão positiva intermitente (NIV) em oposição à pressão positiva bi-nível (PAP) e ambas têm sido referidas, quase exclusivamente, como sendo utilizadas através de interfaces nasais ou oro-nasais, em vez de através de uma simples peça bucal.à referido com frequência a falência da ventilação não invasiva, devido à acumulação de secreções nas vias respiratórias, devido à hipercapnia por deficiente ajuste dos parâmetros da PAP ou devido a uma reduzida tolerância à interface. Esta última pode ser causada por fatores como pressão excessiva na face devido a um ajuste defeituoso, fuga excessiva de ar pela boca, ansiedade, claustrofobia e falta de sincronia entre o doente e o ventilador. Deste modo, a interface tem um papel crucial na tolerância e eficácia. Interfaces que cobrem o nariz e/ou a boca (oro-nasal) são as mais habitualmente usadas, mas são as que apresentam maior propensão a provocarem lesões na pele e claustrofobia. A maioria dos inconvenientes associados pode ser evitada usando VNI por bocal. A VNI de circuito aberto por peça bucal está a ser usada por um número significativo de doentes em alguns centros, na assistência ventilatória diurna e como complemento da VNI noturna através de «máscara». A VNI por peça bucal é igualmente utilizada durante o sono com o bucal fixo na posição, através de uma orla de cobertura do lábio. As peças bucais mais utilizadas são as pequenas anguladas de 15 e 22 mm e as de tipo «palhinha».A VNI através de de peça bucal é usada por um número significativo de doentes como uma alternativa eficaz à ventilação assistida através de tubo de traqueostomia (VTM) e está associada à redução do risco de pneumonias e outras complicações respiratórias. A sua utilização facilita a «acumulação de ar» que aumenta a eficácia da tosse, o discurso e a compliance pulmonar, melhorando a qualidade de vida dos doentes com doenças neuromusculares (DNM) em comparação as alternativas invasivas. Considerando estes benefícios e a disponibilização de modos ventilatórios NIV por peça bucal, é agora garantido um maior conhecimento desta técnica. Esta revisão destaca as indicações, técnicas, vantagens e desvantagens do VNI por peça bucal. Keywords: Noninvasive ventilation, Mouthpiece, Open-circuit mouthpiece ventilation, Neuromuscular disease, Ventilator settings, Palavras-chave: Ventilação não invasiva, Peça Bucal, Ventilação por peça bucal de circuito aberto, Doença neuromuscular, Parâmetros do ventiladorhttp://www.sciencedirect.com/science/article/pii/S087321591400049X