Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation

Prapasri Kulalert,1 Phichayut Phinyo,2,3 Jayanton Patumanond,3 Chutima Smathakanee,4 Wantida Chuenjit,4 Sira Nanthapisal5 1Department of Clinical Epidemiology, Faculty of Medicine, Thammasat University, Pathum Thani, Thailand; 2Department of Family Medicine, Faculty of Medicine, Chiang Mai Universit...

Full description

Bibliographic Details
Main Authors: Kulalert P, Phinyo P, Patumanond J, Smathakanee C, Chuenjit W, Nanthapisal S
Format: Article
Language:English
Published: Dove Medical Press 2020-08-01
Series:Journal of Asthma and Allergy
Subjects:
Online Access:https://www.dovepress.com/factors-associated-with-failure-of-intermittent-nebulization-with-shor-peer-reviewed-article-JAA
id doaj-56fd3395dfb84d89ad70d7708cef34d5
record_format Article
spelling doaj-56fd3395dfb84d89ad70d7708cef34d52020-11-25T03:11:30ZengDove Medical PressJournal of Asthma and Allergy1178-69652020-08-01Volume 1327528356587Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma ExacerbationKulalert PPhinyo PPatumanond JSmathakanee CChuenjit WNanthapisal SPrapasri Kulalert,1 Phichayut Phinyo,2,3 Jayanton Patumanond,3 Chutima Smathakanee,4 Wantida Chuenjit,4 Sira Nanthapisal5 1Department of Clinical Epidemiology, Faculty of Medicine, Thammasat University, Pathum Thani, Thailand; 2Department of Family Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 3Center for Clinical Epidemiology and Clinical Statistics, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 4Department of Pediatrics, Hat Yai Hospital, Songkhla, Thailand; 5Department of Pediatrics, Faculty of Medicine, Thammasat University, Pathum Thani, ThailandCorrespondence: Phichayut PhinyoDepartment of Family Medicine, Faculty of Medicine, Chiang Mai University, 110/510 Intawaroros Road, Suthep, Mueang Chiang Mai District, Chiang Mai, Chiang Mai Province 50200, ThailandTel +66 89 850 1987Email phichayutphinyo@gmail.comPurpose: Intermittent nebulization of short-acting beta-agonists (SABA) is the initial treatment of choice for children with asthma exacerbation. However, children with severe asthma exacerbation (SAE) may not show an adequate response and need aggressive stepwise therapy. We aimed to explore factors associated with a poor response to intermittent nebulized SABA in children with SAE.Methods: A retrospective cohort study of children with SAE diagnosed according to the definition of the British Guidelines on the Management of Asthma, who were admitted at Hat Yai Hospital from January 1, 2015, to December 31, 2017. All children were treated with intermittent SABA nebulization. Treatment failure was defined as children needing escalated therapy. Logistic regression with confounding score adjustment was used to explore the predictors of treatment failure.Results: One hundred thirty-three children were included in the analysis, 59 were in the failure group and 74 were in the success group. After adjusting for potential confounders, they were significantly associated with a previous history of intubation (adjusted OR 6.46, 95% CI 1.13 to 36.79, p=0.036), receiving < 3 doses of nebulized salbutamol in the emergency room (ER, aOR 3.21, 95% CI 1.15 to 9.02, p=0.027), ER measured oxygen saturation (SpO2) < 92% (adjusted OR 3.02, 95% CI 1.18 to 7.75, p=0.022), and exacerbation triggered by pneumonia (adjusted OR 2.67, 95% CI 1.19 to 6.00, p=0.017).Conclusion: We identified four prognostic factors of treatment failure in children with SAE: a previous history of intubation; receiving < 3 doses of nebulized salbutamol in the ER, SpO2 at ER < 92%; and exacerbation triggered by pneumonia. Further prospective studies are required to confirm our findings before clinical implementation.Keywords: status asthmaticus, hospitalization, nebulization, treatment failure, prognosishttps://www.dovepress.com/factors-associated-with-failure-of-intermittent-nebulization-with-shor-peer-reviewed-article-JAAstatus asthmaticushospitalizationnebulizationtreatment failureprognosis
collection DOAJ
language English
format Article
sources DOAJ
author Kulalert P
Phinyo P
Patumanond J
Smathakanee C
Chuenjit W
Nanthapisal S
spellingShingle Kulalert P
Phinyo P
Patumanond J
Smathakanee C
Chuenjit W
Nanthapisal S
Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation
Journal of Asthma and Allergy
status asthmaticus
hospitalization
nebulization
treatment failure
prognosis
author_facet Kulalert P
Phinyo P
Patumanond J
Smathakanee C
Chuenjit W
Nanthapisal S
author_sort Kulalert P
title Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation
title_short Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation
title_full Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation
title_fullStr Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation
title_full_unstemmed Factors Associated with Failure of Intermittent Nebulization with Short-Acting Beta-Agonists in Children with Severe Asthma Exacerbation
title_sort factors associated with failure of intermittent nebulization with short-acting beta-agonists in children with severe asthma exacerbation
publisher Dove Medical Press
series Journal of Asthma and Allergy
issn 1178-6965
publishDate 2020-08-01
description Prapasri Kulalert,1 Phichayut Phinyo,2,3 Jayanton Patumanond,3 Chutima Smathakanee,4 Wantida Chuenjit,4 Sira Nanthapisal5 1Department of Clinical Epidemiology, Faculty of Medicine, Thammasat University, Pathum Thani, Thailand; 2Department of Family Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 3Center for Clinical Epidemiology and Clinical Statistics, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 4Department of Pediatrics, Hat Yai Hospital, Songkhla, Thailand; 5Department of Pediatrics, Faculty of Medicine, Thammasat University, Pathum Thani, ThailandCorrespondence: Phichayut PhinyoDepartment of Family Medicine, Faculty of Medicine, Chiang Mai University, 110/510 Intawaroros Road, Suthep, Mueang Chiang Mai District, Chiang Mai, Chiang Mai Province 50200, ThailandTel +66 89 850 1987Email phichayutphinyo@gmail.comPurpose: Intermittent nebulization of short-acting beta-agonists (SABA) is the initial treatment of choice for children with asthma exacerbation. However, children with severe asthma exacerbation (SAE) may not show an adequate response and need aggressive stepwise therapy. We aimed to explore factors associated with a poor response to intermittent nebulized SABA in children with SAE.Methods: A retrospective cohort study of children with SAE diagnosed according to the definition of the British Guidelines on the Management of Asthma, who were admitted at Hat Yai Hospital from January 1, 2015, to December 31, 2017. All children were treated with intermittent SABA nebulization. Treatment failure was defined as children needing escalated therapy. Logistic regression with confounding score adjustment was used to explore the predictors of treatment failure.Results: One hundred thirty-three children were included in the analysis, 59 were in the failure group and 74 were in the success group. After adjusting for potential confounders, they were significantly associated with a previous history of intubation (adjusted OR 6.46, 95% CI 1.13 to 36.79, p=0.036), receiving < 3 doses of nebulized salbutamol in the emergency room (ER, aOR 3.21, 95% CI 1.15 to 9.02, p=0.027), ER measured oxygen saturation (SpO2) < 92% (adjusted OR 3.02, 95% CI 1.18 to 7.75, p=0.022), and exacerbation triggered by pneumonia (adjusted OR 2.67, 95% CI 1.19 to 6.00, p=0.017).Conclusion: We identified four prognostic factors of treatment failure in children with SAE: a previous history of intubation; receiving < 3 doses of nebulized salbutamol in the ER, SpO2 at ER < 92%; and exacerbation triggered by pneumonia. Further prospective studies are required to confirm our findings before clinical implementation.Keywords: status asthmaticus, hospitalization, nebulization, treatment failure, prognosis
topic status asthmaticus
hospitalization
nebulization
treatment failure
prognosis
url https://www.dovepress.com/factors-associated-with-failure-of-intermittent-nebulization-with-shor-peer-reviewed-article-JAA
work_keys_str_mv AT kulalertp factorsassociatedwithfailureofintermittentnebulizationwithshortactingbetaagonistsinchildrenwithsevereasthmaexacerbation
AT phinyop factorsassociatedwithfailureofintermittentnebulizationwithshortactingbetaagonistsinchildrenwithsevereasthmaexacerbation
AT patumanondj factorsassociatedwithfailureofintermittentnebulizationwithshortactingbetaagonistsinchildrenwithsevereasthmaexacerbation
AT smathakaneec factorsassociatedwithfailureofintermittentnebulizationwithshortactingbetaagonistsinchildrenwithsevereasthmaexacerbation
AT chuenjitw factorsassociatedwithfailureofintermittentnebulizationwithshortactingbetaagonistsinchildrenwithsevereasthmaexacerbation
AT nanthapisals factorsassociatedwithfailureofintermittentnebulizationwithshortactingbetaagonistsinchildrenwithsevereasthmaexacerbation
_version_ 1724653726506942464