Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device
Many sensors have to be used simultaneously for multipoint carbon dioxide (CO2) observation. All the sensors should be calibrated in advance, but this is a time-consuming process. To seek a simplified calibration method, we used four commercial CO2 sensor models and characterized their output tenden...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2012-03-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/12/3/3641/ |
id |
doaj-568a5736e03049788ee06514a8af4d23 |
---|---|
record_format |
Article |
spelling |
doaj-568a5736e03049788ee06514a8af4d232020-11-24T22:22:36ZengMDPI AGSensors1424-82202012-03-011233641365510.3390/s120303641Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement DeviceAkira TaniTomomi YasudaSeiichiro YonemuraMany sensors have to be used simultaneously for multipoint carbon dioxide (CO2) observation. All the sensors should be calibrated in advance, but this is a time-consuming process. To seek a simplified calibration method, we used four commercial CO2 sensor models and characterized their output tendencies against ambient temperature and length of use, in addition to offset characteristics. We used four samples of standard gas with different CO2 concentrations (0, 407, 1,110, and 1,810 ppm). The outputs of K30 and AN100 models showed linear relationships with temperature and length of use. Calibration coefficients for sensor models were determined using the data from three individual sensors of the same model to minimize the relative RMS error. When the correction was applied to the sensors, the accuracy of measurements improved significantly in the case of the K30 and AN100 units. In particular, in the case of K30 the relative RMS error decreased from 24% to 4%. Hence, we have chosen K30 for developing a portable CO2 measurement device (10 × 10 × 15 cm, 900 g). Data of CO2 concentration, measurement time and location, temperature, humidity, and atmospheric pressure can be recorded onto a Secure Digital (SD) memory card. The CO2 concentration in a high-school lecture room was monitored with this device. The CO2 data, when corrected for simultaneously measured temperature, water vapor partial pressure, and atmospheric pressure, showed a good agreement with the data measured by a highly accurate CO2 analyzer, LI-6262. This indicates that acceptable accuracy can be realized using the calibration method developed in this study.http://www.mdpi.com/1424-8220/12/3/3641/multipoint observationCO2 sensorcalibrationportable CO2 measurement device |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Akira Tani Tomomi Yasuda Seiichiro Yonemura |
spellingShingle |
Akira Tani Tomomi Yasuda Seiichiro Yonemura Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device Sensors multipoint observation CO2 sensor calibration portable CO2 measurement device |
author_facet |
Akira Tani Tomomi Yasuda Seiichiro Yonemura |
author_sort |
Akira Tani |
title |
Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device |
title_short |
Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device |
title_full |
Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device |
title_fullStr |
Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device |
title_full_unstemmed |
Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device |
title_sort |
comparison of the characteristics of small commercial ndir co2 sensor models and development of a portable co2 measurement device |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2012-03-01 |
description |
Many sensors have to be used simultaneously for multipoint carbon dioxide (CO2) observation. All the sensors should be calibrated in advance, but this is a time-consuming process. To seek a simplified calibration method, we used four commercial CO2 sensor models and characterized their output tendencies against ambient temperature and length of use, in addition to offset characteristics. We used four samples of standard gas with different CO2 concentrations (0, 407, 1,110, and 1,810 ppm). The outputs of K30 and AN100 models showed linear relationships with temperature and length of use. Calibration coefficients for sensor models were determined using the data from three individual sensors of the same model to minimize the relative RMS error. When the correction was applied to the sensors, the accuracy of measurements improved significantly in the case of the K30 and AN100 units. In particular, in the case of K30 the relative RMS error decreased from 24% to 4%. Hence, we have chosen K30 for developing a portable CO2 measurement device (10 × 10 × 15 cm, 900 g). Data of CO2 concentration, measurement time and location, temperature, humidity, and atmospheric pressure can be recorded onto a Secure Digital (SD) memory card. The CO2 concentration in a high-school lecture room was monitored with this device. The CO2 data, when corrected for simultaneously measured temperature, water vapor partial pressure, and atmospheric pressure, showed a good agreement with the data measured by a highly accurate CO2 analyzer, LI-6262. This indicates that acceptable accuracy can be realized using the calibration method developed in this study. |
topic |
multipoint observation CO2 sensor calibration portable CO2 measurement device |
url |
http://www.mdpi.com/1424-8220/12/3/3641/ |
work_keys_str_mv |
AT akiratani comparisonofthecharacteristicsofsmallcommercialndirco2sensormodelsanddevelopmentofaportableco2measurementdevice AT tomomiyasuda comparisonofthecharacteristicsofsmallcommercialndirco2sensormodelsanddevelopmentofaportableco2measurementdevice AT seiichiroyonemura comparisonofthecharacteristicsofsmallcommercialndirco2sensormodelsanddevelopmentofaportableco2measurementdevice |
_version_ |
1725767606201221120 |