Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone

The Environmental Protection Laboratory of Vilnius Gediminas Technical University has developed and installed a one-level 8-channel cyclone with different internal structure, which is used for separation of particulate matter from air streams. Airflow velocity was measured in five points of each ch...

Full description

Bibliographic Details
Main Authors: Žilvinas Venckus, Albertas Venslovas, Mantas Pranskevičius
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2014-12-01
Series:Journal of Environmental Engineering and Landscape Management
Subjects:
Online Access:http://journals.vgtu.lt/index.php/JEELM/article/view/1822
id doaj-564aaf72cb8b4a76a7572bffaab8f64e
record_format Article
spelling doaj-564aaf72cb8b4a76a7572bffaab8f64e2021-07-02T10:36:07ZengVilnius Gediminas Technical UniversityJournal of Environmental Engineering and Landscape Management1648-68971822-41992014-12-0122410.3846/16486897.2014.973415Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cycloneŽilvinas Venckus0Albertas Venslovas1Mantas Pranskevičius2Institute of Environmental Protection, Vilnius Gediminas Technical University, Saulėtekio al. 11, LT-10223 Vilnius, LithuaniaInstitute of Environmental Protection, Vilnius Gediminas Technical University, Saulėtekio al. 11, 10223 Vilnius, LithuaniaInstitute of Environmental Protection, Vilnius Gediminas Technical University, Saulėtekio al. 11, 10223 Vilnius, Lithuania The Environmental Protection Laboratory of Vilnius Gediminas Technical University has developed and installed a one-level 8-channel cyclone with different internal structure, which is used for separation of particulate matter from air streams. Airflow velocity was measured in five points of each channel: at the end and the beginning of the channel, in the middle of the channel and in points arranged at 45° angle from the channel's end and beginning. The highest airflow velocity determined in 8-channel device by regulating volumes of peripheral and transit airflows with curvilinear semi-rings was in cyclone's channel 1, while the lowest – in channel 2. Contrary to the above, the highest airflow velocity in 8-channel cyclone by using quarter-rings without holes and with 5° opening angle of plates in holes was recorded in channel 2. Tests on aerodynamic resistance were carried out in airflow inlet and outlet ducts. In all cases analysed the highest aerodynamic resistance in 8-channel cyclone was determined when airflow distribution was regulated at 75/25 ratio with semi-rings. When quarter-rings without holes and with 5° opening angle of plates in holes were used, higher aerodynamic resistance in the system was created by using quarter-rings without holes, i.e. 0° opening of plates. http://journals.vgtu.lt/index.php/JEELM/article/view/1822cyclonesemi-ringquarter-ringairflowparticulate matterair cleaning
collection DOAJ
language English
format Article
sources DOAJ
author Žilvinas Venckus
Albertas Venslovas
Mantas Pranskevičius
spellingShingle Žilvinas Venckus
Albertas Venslovas
Mantas Pranskevičius
Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
Journal of Environmental Engineering and Landscape Management
cyclone
semi-ring
quarter-ring
airflow
particulate matter
air cleaning
author_facet Žilvinas Venckus
Albertas Venslovas
Mantas Pranskevičius
author_sort Žilvinas Venckus
title Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
title_short Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
title_full Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
title_fullStr Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
title_full_unstemmed Experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
title_sort experimental research into aerodynamic parameters of a cylindrical one-level 8-channel cyclone
publisher Vilnius Gediminas Technical University
series Journal of Environmental Engineering and Landscape Management
issn 1648-6897
1822-4199
publishDate 2014-12-01
description The Environmental Protection Laboratory of Vilnius Gediminas Technical University has developed and installed a one-level 8-channel cyclone with different internal structure, which is used for separation of particulate matter from air streams. Airflow velocity was measured in five points of each channel: at the end and the beginning of the channel, in the middle of the channel and in points arranged at 45° angle from the channel's end and beginning. The highest airflow velocity determined in 8-channel device by regulating volumes of peripheral and transit airflows with curvilinear semi-rings was in cyclone's channel 1, while the lowest – in channel 2. Contrary to the above, the highest airflow velocity in 8-channel cyclone by using quarter-rings without holes and with 5° opening angle of plates in holes was recorded in channel 2. Tests on aerodynamic resistance were carried out in airflow inlet and outlet ducts. In all cases analysed the highest aerodynamic resistance in 8-channel cyclone was determined when airflow distribution was regulated at 75/25 ratio with semi-rings. When quarter-rings without holes and with 5° opening angle of plates in holes were used, higher aerodynamic resistance in the system was created by using quarter-rings without holes, i.e. 0° opening of plates.
topic cyclone
semi-ring
quarter-ring
airflow
particulate matter
air cleaning
url http://journals.vgtu.lt/index.php/JEELM/article/view/1822
work_keys_str_mv AT zilvinasvenckus experimentalresearchintoaerodynamicparametersofacylindricalonelevel8channelcyclone
AT albertasvenslovas experimentalresearchintoaerodynamicparametersofacylindricalonelevel8channelcyclone
AT mantaspranskevicius experimentalresearchintoaerodynamicparametersofacylindricalonelevel8channelcyclone
_version_ 1721331889362436096