Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter

OBJECTIVE: to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo. METHOD: a quantitative, exploratory-descriptive...

Full description

Bibliographic Details
Main Authors: Késia Alves Gomes Rosetti, Daisy Maria Rizatto Tronchin
Format: Article
Language:English
Published: Universidade de São Paulo 2014-01-01
Series:Revista Latino-Americana de Enfermagem
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692014000100129&lng=en&tlng=en
id doaj-56206b34110140c59337e47b27734c3b
record_format Article
spelling doaj-56206b34110140c59337e47b27734c3b2020-11-24T22:14:38ZengUniversidade de São PauloRevista Latino-Americana de Enfermagem1518-83452014-01-0122112913510.1590/0104-1169.2959.2378S0104-11692014000100129Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheterKésia Alves Gomes RosettiDaisy Maria Rizatto TronchinOBJECTIVE: to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo. METHOD: a quantitative, exploratory-descriptive and observational study. The sample was made up of 155 observations of persons with temporary double-lumen catheters, in the period March - November 2011, using the Indicator of the Maintenance of the Temporary Double Lumen Catheter for Hemodialysis. RESULTS: the rate of general conformity of the assistential practice corresponded to 65.8%. Of the practice's 13 components, 9 (69.2%) attained 100% conformity. The hygienization of hands by the professionals and the use of a mask by the patients during the disconnection from the hemodialysis had the worst rates (83.9%). CONCLUSION: although the actions evaluated are implemented in the unit, it is necessary to propose and apply educational strategies with the health team, as well as to institute periodical assessments, so as to raise the conformity rates, ensuring the quality of the hemodialysis services.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692014000100129&lng=en&tlng=enCalidad de la Atención de la SaludEvaluación de Servicios de SaludIndicadores de Calidad de la Atención de SaludDiálisis RenalEnfermería
collection DOAJ
language English
format Article
sources DOAJ
author Késia Alves Gomes Rosetti
Daisy Maria Rizatto Tronchin
spellingShingle Késia Alves Gomes Rosetti
Daisy Maria Rizatto Tronchin
Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
Revista Latino-Americana de Enfermagem
Calidad de la Atención de la Salud
Evaluación de Servicios de Salud
Indicadores de Calidad de la Atención de Salud
Diálisis Renal
Enfermería
author_facet Késia Alves Gomes Rosetti
Daisy Maria Rizatto Tronchin
author_sort Késia Alves Gomes Rosetti
title Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
title_short Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
title_full Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
title_fullStr Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
title_full_unstemmed Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
title_sort evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter
publisher Universidade de São Paulo
series Revista Latino-Americana de Enfermagem
issn 1518-8345
publishDate 2014-01-01
description OBJECTIVE: to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo. METHOD: a quantitative, exploratory-descriptive and observational study. The sample was made up of 155 observations of persons with temporary double-lumen catheters, in the period March - November 2011, using the Indicator of the Maintenance of the Temporary Double Lumen Catheter for Hemodialysis. RESULTS: the rate of general conformity of the assistential practice corresponded to 65.8%. Of the practice's 13 components, 9 (69.2%) attained 100% conformity. The hygienization of hands by the professionals and the use of a mask by the patients during the disconnection from the hemodialysis had the worst rates (83.9%). CONCLUSION: although the actions evaluated are implemented in the unit, it is necessary to propose and apply educational strategies with the health team, as well as to institute periodical assessments, so as to raise the conformity rates, ensuring the quality of the hemodialysis services.
topic Calidad de la Atención de la Salud
Evaluación de Servicios de Salud
Indicadores de Calidad de la Atención de Salud
Diálisis Renal
Enfermería
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692014000100129&lng=en&tlng=en
work_keys_str_mv AT kesiaalvesgomesrosetti evaluationoftheconformityofassistentialpracticeinthemaintenanceofthetemporarydoublelumendialysiscatheter
AT daisymariarizattotronchin evaluationoftheconformityofassistentialpracticeinthemaintenanceofthetemporarydoublelumendialysiscatheter
_version_ 1725797844000964608