Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks

Islanding detection is essential for reliable and safe operation of systems with distributed generations (DG). In systems with multiple DGs, the interaction between DGs can make the islanding detection process more challenging. To address this concern, this paper proposes a two-stage islanding detec...

Full description

Bibliographic Details
Main Authors: M. Mohiti, S. Sabzevari, P. Siano
Format: Article
Language:English
Published: Iran University of Science and Technology 2021-09-01
Series:Iranian Journal of Electrical and Electronic Engineering
Subjects:
Online Access:http://ijeee.iust.ac.ir/article-1-1945-en.html
id doaj-55c6570903e54b96818df58cefddec3e
record_format Article
spelling doaj-55c6570903e54b96818df58cefddec3e2021-02-25T05:46:13ZengIran University of Science and TechnologyIranian Journal of Electrical and Electronic Engineering1735-28272383-38902021-09-0117319451945Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG NetworksM. Mohiti0S. Sabzevari1P. Siano2 Department of Electrical Engineering, Yazd University, Yazd, Iran. Department of Electrical and Computer Engineering, Semnan University, Semnan, Iran. Department of Management & Innovation Systems, University of Salerno, Salerno, Italy. Islanding detection is essential for reliable and safe operation of systems with distributed generations (DG). In systems with multiple DGs, the interaction between DGs can make the islanding detection process more challenging. To address this concern, this paper proposes a two-stage islanding detection method for power systems equipped with multiple-DGs through estimation of high frequency impedance (Zf) and determination of the total harmonic distortion (THD). The impedances of the DGs are estimated at distinct frequencies to avoid interval overlaps. The concept of different frequency bands makes the proposed method applicable to multiple DG systems. To evaluate the effectiveness of the proposed method, a test system with multiple DGs is simulated through several case studies in PSCAD/EMTDC. The simulation results demonstrate the accuracy of the proposed islanding detection method in both single and multi-DG systems. It is also shown that the proposed method remains robust under different operating conditions and events.http://ijeee.iust.ac.ir/article-1-1945-en.htmlislanding detectiondecentralized methodhigh frequencyimpedance estimationmulti-dg.
collection DOAJ
language English
format Article
sources DOAJ
author M. Mohiti
S. Sabzevari
P. Siano
spellingShingle M. Mohiti
S. Sabzevari
P. Siano
Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks
Iranian Journal of Electrical and Electronic Engineering
islanding detection
decentralized method
high frequency
impedance estimation
multi-dg.
author_facet M. Mohiti
S. Sabzevari
P. Siano
author_sort M. Mohiti
title Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks
title_short Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks
title_full Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks
title_fullStr Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks
title_full_unstemmed Two-Stage Islanding Detection Method via High Frequency Impedance and Harmonic Distortion Evaluation in Multi-DG Networks
title_sort two-stage islanding detection method via high frequency impedance and harmonic distortion evaluation in multi-dg networks
publisher Iran University of Science and Technology
series Iranian Journal of Electrical and Electronic Engineering
issn 1735-2827
2383-3890
publishDate 2021-09-01
description Islanding detection is essential for reliable and safe operation of systems with distributed generations (DG). In systems with multiple DGs, the interaction between DGs can make the islanding detection process more challenging. To address this concern, this paper proposes a two-stage islanding detection method for power systems equipped with multiple-DGs through estimation of high frequency impedance (Zf) and determination of the total harmonic distortion (THD). The impedances of the DGs are estimated at distinct frequencies to avoid interval overlaps. The concept of different frequency bands makes the proposed method applicable to multiple DG systems. To evaluate the effectiveness of the proposed method, a test system with multiple DGs is simulated through several case studies in PSCAD/EMTDC. The simulation results demonstrate the accuracy of the proposed islanding detection method in both single and multi-DG systems. It is also shown that the proposed method remains robust under different operating conditions and events.
topic islanding detection
decentralized method
high frequency
impedance estimation
multi-dg.
url http://ijeee.iust.ac.ir/article-1-1945-en.html
work_keys_str_mv AT mmohiti twostageislandingdetectionmethodviahighfrequencyimpedanceandharmonicdistortionevaluationinmultidgnetworks
AT ssabzevari twostageislandingdetectionmethodviahighfrequencyimpedanceandharmonicdistortionevaluationinmultidgnetworks
AT psiano twostageislandingdetectionmethodviahighfrequencyimpedanceandharmonicdistortionevaluationinmultidgnetworks
_version_ 1724252067336290304