The clinical features of simple myopic astigmatism

Purpose: Evaluation of the clinical features of simple myopic astigmatism.Methods: In the framework of the follow-up observation of surveyed 64 patients (128 eyes) with the phenomena of simple myopic astigmatism in both eyes without concomitant ocular pathology.Results: the most common are weak (up...

Full description

Bibliographic Details
Main Authors: S. I. Abramov, A. A. Kozhuhov, A. V. Zhemchugova, V. V. Kurenkov
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2014-07-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/149
id doaj-54da2959462140ce9c53a785c33efc92
record_format Article
spelling doaj-54da2959462140ce9c53a785c33efc922021-07-29T08:55:22ZrusOphthalmology Publishing GroupOftalʹmologiâ 1816-50952014-07-0193252810.18008/1816-5095-2012-3-25-28149The clinical features of simple myopic astigmatismS. I. Abramov0A. A. Kozhuhov1A. V. Zhemchugova2V. V. Kurenkov3Кафедра офтальмологии ФГБОУ ДПО «Институт повышения квалификации Федерального медико- биологического агентства России», 123098 Москва, ул. Гамалеи, 15Кафедра офтальмологии ФГБОУ ДПО «Институт повышения квалификации Федерального медико- биологического агентства России», 123098 Москва, ул. Гамалеи, 15Клиника доктора Куренкова, Москва, РоссияКлиника доктора Куренкова, Москва, РоссияPurpose: Evaluation of the clinical features of simple myopic astigmatism.Methods: In the framework of the follow-up observation of surveyed 64 patients (128 eyes) with the phenomena of simple myopic astigmatism in both eyes without concomitant ocular pathology.Results: the most common are weak (up to 1.0 D — 42%, 1.25-2.0 D — 28%) of the value, expressed astigmatism (more than 2.0 D) is observed in 30% of cases. In terms of direct myopic astigmatism up to 1.0 D the most characteristic visual acuity is 0.6-0.7, when the value of astigmatism from 1.25 up to 2.0 D the most frequently noted visual acuity is 0.3-0.5. the indicator of «primary use» statistically significantly depended on the indicator «astenopic complaints» (correlation coefficient was 0.59 is 0.72, p<0.0001).Conclusion: the emergence of the patient with visually-intensive work (especially working in conditions of shortage of time) re- quires of excimer laser correction for the preservation of visual capacity and the required level of professional reliability, as well as the extension of the professional longevity of the body of view.https://www.ophthalmojournal.com/opht/article/view/149simple myopic astigmatismshort-sightednessvisually hard work
collection DOAJ
language Russian
format Article
sources DOAJ
author S. I. Abramov
A. A. Kozhuhov
A. V. Zhemchugova
V. V. Kurenkov
spellingShingle S. I. Abramov
A. A. Kozhuhov
A. V. Zhemchugova
V. V. Kurenkov
The clinical features of simple myopic astigmatism
Oftalʹmologiâ
simple myopic astigmatism
short-sightedness
visually hard work
author_facet S. I. Abramov
A. A. Kozhuhov
A. V. Zhemchugova
V. V. Kurenkov
author_sort S. I. Abramov
title The clinical features of simple myopic astigmatism
title_short The clinical features of simple myopic astigmatism
title_full The clinical features of simple myopic astigmatism
title_fullStr The clinical features of simple myopic astigmatism
title_full_unstemmed The clinical features of simple myopic astigmatism
title_sort clinical features of simple myopic astigmatism
publisher Ophthalmology Publishing Group
series Oftalʹmologiâ
issn 1816-5095
publishDate 2014-07-01
description Purpose: Evaluation of the clinical features of simple myopic astigmatism.Methods: In the framework of the follow-up observation of surveyed 64 patients (128 eyes) with the phenomena of simple myopic astigmatism in both eyes without concomitant ocular pathology.Results: the most common are weak (up to 1.0 D — 42%, 1.25-2.0 D — 28%) of the value, expressed astigmatism (more than 2.0 D) is observed in 30% of cases. In terms of direct myopic astigmatism up to 1.0 D the most characteristic visual acuity is 0.6-0.7, when the value of astigmatism from 1.25 up to 2.0 D the most frequently noted visual acuity is 0.3-0.5. the indicator of «primary use» statistically significantly depended on the indicator «astenopic complaints» (correlation coefficient was 0.59 is 0.72, p<0.0001).Conclusion: the emergence of the patient with visually-intensive work (especially working in conditions of shortage of time) re- quires of excimer laser correction for the preservation of visual capacity and the required level of professional reliability, as well as the extension of the professional longevity of the body of view.
topic simple myopic astigmatism
short-sightedness
visually hard work
url https://www.ophthalmojournal.com/opht/article/view/149
work_keys_str_mv AT siabramov theclinicalfeaturesofsimplemyopicastigmatism
AT aakozhuhov theclinicalfeaturesofsimplemyopicastigmatism
AT avzhemchugova theclinicalfeaturesofsimplemyopicastigmatism
AT vvkurenkov theclinicalfeaturesofsimplemyopicastigmatism
AT siabramov clinicalfeaturesofsimplemyopicastigmatism
AT aakozhuhov clinicalfeaturesofsimplemyopicastigmatism
AT avzhemchugova clinicalfeaturesofsimplemyopicastigmatism
AT vvkurenkov clinicalfeaturesofsimplemyopicastigmatism
_version_ 1721251119873654784