The clinical features of simple myopic astigmatism
Purpose: Evaluation of the clinical features of simple myopic astigmatism.Methods: In the framework of the follow-up observation of surveyed 64 patients (128 eyes) with the phenomena of simple myopic astigmatism in both eyes without concomitant ocular pathology.Results: the most common are weak (up...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Ophthalmology Publishing Group
2014-07-01
|
Series: | Oftalʹmologiâ |
Subjects: | |
Online Access: | https://www.ophthalmojournal.com/opht/article/view/149 |
id |
doaj-54da2959462140ce9c53a785c33efc92 |
---|---|
record_format |
Article |
spelling |
doaj-54da2959462140ce9c53a785c33efc922021-07-29T08:55:22ZrusOphthalmology Publishing GroupOftalʹmologiâ 1816-50952014-07-0193252810.18008/1816-5095-2012-3-25-28149The clinical features of simple myopic astigmatismS. I. Abramov0A. A. Kozhuhov1A. V. Zhemchugova2V. V. Kurenkov3Кафедра офтальмологии ФГБОУ ДПО «Институт повышения квалификации Федерального медико- биологического агентства России», 123098 Москва, ул. Гамалеи, 15Кафедра офтальмологии ФГБОУ ДПО «Институт повышения квалификации Федерального медико- биологического агентства России», 123098 Москва, ул. Гамалеи, 15Клиника доктора Куренкова, Москва, РоссияКлиника доктора Куренкова, Москва, РоссияPurpose: Evaluation of the clinical features of simple myopic astigmatism.Methods: In the framework of the follow-up observation of surveyed 64 patients (128 eyes) with the phenomena of simple myopic astigmatism in both eyes without concomitant ocular pathology.Results: the most common are weak (up to 1.0 D — 42%, 1.25-2.0 D — 28%) of the value, expressed astigmatism (more than 2.0 D) is observed in 30% of cases. In terms of direct myopic astigmatism up to 1.0 D the most characteristic visual acuity is 0.6-0.7, when the value of astigmatism from 1.25 up to 2.0 D the most frequently noted visual acuity is 0.3-0.5. the indicator of «primary use» statistically significantly depended on the indicator «astenopic complaints» (correlation coefficient was 0.59 is 0.72, p<0.0001).Conclusion: the emergence of the patient with visually-intensive work (especially working in conditions of shortage of time) re- quires of excimer laser correction for the preservation of visual capacity and the required level of professional reliability, as well as the extension of the professional longevity of the body of view.https://www.ophthalmojournal.com/opht/article/view/149simple myopic astigmatismshort-sightednessvisually hard work |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
S. I. Abramov A. A. Kozhuhov A. V. Zhemchugova V. V. Kurenkov |
spellingShingle |
S. I. Abramov A. A. Kozhuhov A. V. Zhemchugova V. V. Kurenkov The clinical features of simple myopic astigmatism Oftalʹmologiâ simple myopic astigmatism short-sightedness visually hard work |
author_facet |
S. I. Abramov A. A. Kozhuhov A. V. Zhemchugova V. V. Kurenkov |
author_sort |
S. I. Abramov |
title |
The clinical features of simple myopic astigmatism |
title_short |
The clinical features of simple myopic astigmatism |
title_full |
The clinical features of simple myopic astigmatism |
title_fullStr |
The clinical features of simple myopic astigmatism |
title_full_unstemmed |
The clinical features of simple myopic astigmatism |
title_sort |
clinical features of simple myopic astigmatism |
publisher |
Ophthalmology Publishing Group |
series |
Oftalʹmologiâ |
issn |
1816-5095 |
publishDate |
2014-07-01 |
description |
Purpose: Evaluation of the clinical features of simple myopic astigmatism.Methods: In the framework of the follow-up observation of surveyed 64 patients (128 eyes) with the phenomena of simple myopic astigmatism in both eyes without concomitant ocular pathology.Results: the most common are weak (up to 1.0 D — 42%, 1.25-2.0 D — 28%) of the value, expressed astigmatism (more than 2.0 D) is observed in 30% of cases. In terms of direct myopic astigmatism up to 1.0 D the most characteristic visual acuity is 0.6-0.7, when the value of astigmatism from 1.25 up to 2.0 D the most frequently noted visual acuity is 0.3-0.5. the indicator of «primary use» statistically significantly depended on the indicator «astenopic complaints» (correlation coefficient was 0.59 is 0.72, p<0.0001).Conclusion: the emergence of the patient with visually-intensive work (especially working in conditions of shortage of time) re- quires of excimer laser correction for the preservation of visual capacity and the required level of professional reliability, as well as the extension of the professional longevity of the body of view. |
topic |
simple myopic astigmatism short-sightedness visually hard work |
url |
https://www.ophthalmojournal.com/opht/article/view/149 |
work_keys_str_mv |
AT siabramov theclinicalfeaturesofsimplemyopicastigmatism AT aakozhuhov theclinicalfeaturesofsimplemyopicastigmatism AT avzhemchugova theclinicalfeaturesofsimplemyopicastigmatism AT vvkurenkov theclinicalfeaturesofsimplemyopicastigmatism AT siabramov clinicalfeaturesofsimplemyopicastigmatism AT aakozhuhov clinicalfeaturesofsimplemyopicastigmatism AT avzhemchugova clinicalfeaturesofsimplemyopicastigmatism AT vvkurenkov clinicalfeaturesofsimplemyopicastigmatism |
_version_ |
1721251119873654784 |