Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal
This study aimed to evaluate and compare the fatigue resistance of ProTaper Gold (PTG) and ProTaper Universal (PTU) in artificial single and double curvature canals in 5% sodium hypochlorite (NaOCl) at body temperature (37 °C). PTG and PTU files (size F1) were subjected to fatigue tests in two diffe...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
KeAi Communications Co., Ltd.
2019-12-01
|
Series: | Bioactive Materials |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2452199X1930043X |
id |
doaj-54bef1ea0a284ebe9e55d2f1cd93ce33 |
---|---|
record_format |
Article |
spelling |
doaj-54bef1ea0a284ebe9e55d2f1cd93ce332021-04-02T13:30:31ZengKeAi Communications Co., Ltd.Bioactive Materials2452-199X2019-12-014245248Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canalFahda Algahtani0Xiangya Huang1Markus Haapasalo2Zhejun Wang3Ahmed Hieawy4Duo Zhang5Jolanta Aleksejuniene6Ya Shen7Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada; College of Dentistry, Princess Nourah Bint Abdulrahman University, Saudi ArabiaDepartment of Conservative Dentistry and Endodontics, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China; Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, CanadaDepartment of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, CanadaDepartment of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, CanadaDepartment of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, CanadaDepartment of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, CanadaDepartment of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, CanadaDepartment of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada; Corresponding author. Division of Endodontics Department of Oral Biological & Medical Sciences, UBC Faculty of Dentistry, 2199 Wesbrook Mall, Vancouver, BC, V6T 1Z3, Canada.This study aimed to evaluate and compare the fatigue resistance of ProTaper Gold (PTG) and ProTaper Universal (PTU) in artificial single and double curvature canals in 5% sodium hypochlorite (NaOCl) at body temperature (37 °C). PTG and PTU files (size F1) were subjected to fatigue tests in two different artificial ceramic canals. The single curvature model had a 60° curvature angle with a 5 mm radius. The double curvature model had a 60° curvature angle with a 5 mm radius and a second 30° curvature with a 2 mm radius. A file segment was introduced into the artificial canal and immersed in water or 5% NaOCl at 37 °C. The total number of cycles to fracture (NCF) was recorded. Data were analyzed using t-test and linear regression analysis. The NCF of all files was significantly influenced by the type of NiTi metal alloy (P < .01), canal curvatures (P < .01), and the environmental conditions (P < .05). PTG had higher fatigue resistance than PTU files in both single and double curvature canals (P < .05). The NCF of PTU files in 5% NaOCl was shorter than that in water (P < .05). The mean length of broken PTG was significantly shorter than those of PTU files in both single and double curvature canals (P < .01). The fatigue performance of PTG is better than that of PTU in both single and double curvature. Environmental conditions may affect the fatigue behavior of PTU files with single curvature. Keywords: Body temperature, Corrosion, Double curvature, Fatigue resistance, ProTaper Goldhttp://www.sciencedirect.com/science/article/pii/S2452199X1930043X |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Fahda Algahtani Xiangya Huang Markus Haapasalo Zhejun Wang Ahmed Hieawy Duo Zhang Jolanta Aleksejuniene Ya Shen |
spellingShingle |
Fahda Algahtani Xiangya Huang Markus Haapasalo Zhejun Wang Ahmed Hieawy Duo Zhang Jolanta Aleksejuniene Ya Shen Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal Bioactive Materials |
author_facet |
Fahda Algahtani Xiangya Huang Markus Haapasalo Zhejun Wang Ahmed Hieawy Duo Zhang Jolanta Aleksejuniene Ya Shen |
author_sort |
Fahda Algahtani |
title |
Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal |
title_short |
Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal |
title_full |
Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal |
title_fullStr |
Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal |
title_full_unstemmed |
Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal |
title_sort |
fatigue resistance of protaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal |
publisher |
KeAi Communications Co., Ltd. |
series |
Bioactive Materials |
issn |
2452-199X |
publishDate |
2019-12-01 |
description |
This study aimed to evaluate and compare the fatigue resistance of ProTaper Gold (PTG) and ProTaper Universal (PTU) in artificial single and double curvature canals in 5% sodium hypochlorite (NaOCl) at body temperature (37 °C). PTG and PTU files (size F1) were subjected to fatigue tests in two different artificial ceramic canals. The single curvature model had a 60° curvature angle with a 5 mm radius. The double curvature model had a 60° curvature angle with a 5 mm radius and a second 30° curvature with a 2 mm radius. A file segment was introduced into the artificial canal and immersed in water or 5% NaOCl at 37 °C. The total number of cycles to fracture (NCF) was recorded. Data were analyzed using t-test and linear regression analysis. The NCF of all files was significantly influenced by the type of NiTi metal alloy (P < .01), canal curvatures (P < .01), and the environmental conditions (P < .05). PTG had higher fatigue resistance than PTU files in both single and double curvature canals (P < .05). The NCF of PTU files in 5% NaOCl was shorter than that in water (P < .05). The mean length of broken PTG was significantly shorter than those of PTU files in both single and double curvature canals (P < .01). The fatigue performance of PTG is better than that of PTU in both single and double curvature. Environmental conditions may affect the fatigue behavior of PTU files with single curvature. Keywords: Body temperature, Corrosion, Double curvature, Fatigue resistance, ProTaper Gold |
url |
http://www.sciencedirect.com/science/article/pii/S2452199X1930043X |
work_keys_str_mv |
AT fahdaalgahtani fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT xiangyahuang fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT markushaapasalo fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT zhejunwang fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT ahmedhieawy fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT duozhang fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT jolantaaleksejuniene fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal AT yashen fatigueresistanceofprotapergoldexposedtohighconcentrationsodiumhypochloriteindoublecurvatureartificialcanal |
_version_ |
1721564794190823424 |