Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations

Juraj Artner, Balkan Cakir, Heiko Reichel, Friederike LattigDepartment of Orthopaedic Surgery, University of Ulm, RKU, GermanyBackground: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used i...

Full description

Bibliographic Details
Main Authors: Artner J, Cakir B, Reichel H, Lattig F
Format: Article
Language:English
Published: Dove Medical Press 2012-08-01
Series:Journal of Pain Research
Online Access:http://www.dovepress.com/radiation-dose-reduction-in-ct-guided-sacroiliac-joint-injections-to-l-a10670
id doaj-54223070105741d39d4f74aa88951b5f
record_format Article
spelling doaj-54223070105741d39d4f74aa88951b5f2020-11-24T21:26:10ZengDove Medical PressJournal of Pain Research1178-70902012-08-012012default265269Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerationsArtner JCakir BReichel HLattig FJuraj Artner, Balkan Cakir, Heiko Reichel, Friederike LattigDepartment of Orthopaedic Surgery, University of Ulm, RKU, GermanyBackground: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique.Objective: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections.Study design: Comparative study with technical considerations.Methods: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided.Results: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy-guidance levels.Conclusion: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible.Keywords: sacroiliac joint pain, computed tomography, guided injections, low-dose protocol, sacroiliac joint injection, low back pain, radiation dosehttp://www.dovepress.com/radiation-dose-reduction-in-ct-guided-sacroiliac-joint-injections-to-l-a10670
collection DOAJ
language English
format Article
sources DOAJ
author Artner J
Cakir B
Reichel H
Lattig F
spellingShingle Artner J
Cakir B
Reichel H
Lattig F
Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
Journal of Pain Research
author_facet Artner J
Cakir B
Reichel H
Lattig F
author_sort Artner J
title Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_short Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_full Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_fullStr Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_full_unstemmed Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_sort radiation dose reduction in ct-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
publisher Dove Medical Press
series Journal of Pain Research
issn 1178-7090
publishDate 2012-08-01
description Juraj Artner, Balkan Cakir, Heiko Reichel, Friederike LattigDepartment of Orthopaedic Surgery, University of Ulm, RKU, GermanyBackground: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique.Objective: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections.Study design: Comparative study with technical considerations.Methods: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided.Results: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy-guidance levels.Conclusion: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible.Keywords: sacroiliac joint pain, computed tomography, guided injections, low-dose protocol, sacroiliac joint injection, low back pain, radiation dose
url http://www.dovepress.com/radiation-dose-reduction-in-ct-guided-sacroiliac-joint-injections-to-l-a10670
work_keys_str_mv AT artnerj radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
AT cakirb radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
AT reichelh radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
AT lattigf radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
_version_ 1725980529057071104