Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.

<h4>Purpose</h4>To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.<h4>Materials and methods</h4>We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession...

Full description

Bibliographic Details
Main Authors: Sebastian Berisha, Joyce Han, Mohammed Shahid, Yuchi Han, Walter R T Witschey
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0151144
id doaj-53598771f8af4f8cb3edd95a39335731
record_format Article
spelling doaj-53598771f8af4f8cb3edd95a393357312021-03-04T11:32:58ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01113e015114410.1371/journal.pone.0151144Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.Sebastian BerishaJoyce HanMohammed ShahidYuchi HanWalter R T Witschey<h4>Purpose</h4>To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.<h4>Materials and methods</h4>We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical flow-based image registration method was used to align T1ρ images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs), 1 patient with chronic myocardial infarction (MI) and 2 patients with hypertrophic cardiomyopathy (HCM).<h4>Results</h4>In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom) and 0.9 ± 0.9 msec (60 msec phantom) at 60 bpm and 2.2 ± 3.2 msec (100 msec) and 1.4 ± 0.9 msec (60 msec) at 80 bpm. The coefficient of variation (COV) was 2.2 (100 msec) and 1.3 (60 msec) at 60 bpm and 2.6 (100 msec) and 1.4 (60 msec) at 80 bpm. Motion correction improved the alignment of T1ρ images in subjects, as determined by the increase in Dice Score Coefficient (DSC) from 0.76 to 0.88. T1ρ reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC) = 0.85-0.97). Mean myocardial T1ρ value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE) MRI and increased T1ρ relaxation times in patients.<h4>Conclusion</h4>Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T1ρ mapping in a breath-hold with good accuracy and precision.https://doi.org/10.1371/journal.pone.0151144
collection DOAJ
language English
format Article
sources DOAJ
author Sebastian Berisha
Joyce Han
Mohammed Shahid
Yuchi Han
Walter R T Witschey
spellingShingle Sebastian Berisha
Joyce Han
Mohammed Shahid
Yuchi Han
Walter R T Witschey
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
PLoS ONE
author_facet Sebastian Berisha
Joyce Han
Mohammed Shahid
Yuchi Han
Walter R T Witschey
author_sort Sebastian Berisha
title Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
title_short Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
title_full Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
title_fullStr Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
title_full_unstemmed Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
title_sort measurement of myocardial t1ρ with a motion corrected, parametric mapping sequence in humans.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description <h4>Purpose</h4>To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.<h4>Materials and methods</h4>We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical flow-based image registration method was used to align T1ρ images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs), 1 patient with chronic myocardial infarction (MI) and 2 patients with hypertrophic cardiomyopathy (HCM).<h4>Results</h4>In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom) and 0.9 ± 0.9 msec (60 msec phantom) at 60 bpm and 2.2 ± 3.2 msec (100 msec) and 1.4 ± 0.9 msec (60 msec) at 80 bpm. The coefficient of variation (COV) was 2.2 (100 msec) and 1.3 (60 msec) at 60 bpm and 2.6 (100 msec) and 1.4 (60 msec) at 80 bpm. Motion correction improved the alignment of T1ρ images in subjects, as determined by the increase in Dice Score Coefficient (DSC) from 0.76 to 0.88. T1ρ reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC) = 0.85-0.97). Mean myocardial T1ρ value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE) MRI and increased T1ρ relaxation times in patients.<h4>Conclusion</h4>Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T1ρ mapping in a breath-hold with good accuracy and precision.
url https://doi.org/10.1371/journal.pone.0151144
work_keys_str_mv AT sebastianberisha measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans
AT joycehan measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans
AT mohammedshahid measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans
AT yuchihan measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans
AT walterrtwitschey measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans
_version_ 1714803547866923008