Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.
<h4>Purpose</h4>To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.<h4>Materials and methods</h4>We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2016-01-01
|
Series: | PLoS ONE |
Online Access: | https://doi.org/10.1371/journal.pone.0151144 |
id |
doaj-53598771f8af4f8cb3edd95a39335731 |
---|---|
record_format |
Article |
spelling |
doaj-53598771f8af4f8cb3edd95a393357312021-03-04T11:32:58ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01113e015114410.1371/journal.pone.0151144Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans.Sebastian BerishaJoyce HanMohammed ShahidYuchi HanWalter R T Witschey<h4>Purpose</h4>To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.<h4>Materials and methods</h4>We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical flow-based image registration method was used to align T1ρ images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs), 1 patient with chronic myocardial infarction (MI) and 2 patients with hypertrophic cardiomyopathy (HCM).<h4>Results</h4>In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom) and 0.9 ± 0.9 msec (60 msec phantom) at 60 bpm and 2.2 ± 3.2 msec (100 msec) and 1.4 ± 0.9 msec (60 msec) at 80 bpm. The coefficient of variation (COV) was 2.2 (100 msec) and 1.3 (60 msec) at 60 bpm and 2.6 (100 msec) and 1.4 (60 msec) at 80 bpm. Motion correction improved the alignment of T1ρ images in subjects, as determined by the increase in Dice Score Coefficient (DSC) from 0.76 to 0.88. T1ρ reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC) = 0.85-0.97). Mean myocardial T1ρ value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE) MRI and increased T1ρ relaxation times in patients.<h4>Conclusion</h4>Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T1ρ mapping in a breath-hold with good accuracy and precision.https://doi.org/10.1371/journal.pone.0151144 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sebastian Berisha Joyce Han Mohammed Shahid Yuchi Han Walter R T Witschey |
spellingShingle |
Sebastian Berisha Joyce Han Mohammed Shahid Yuchi Han Walter R T Witschey Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans. PLoS ONE |
author_facet |
Sebastian Berisha Joyce Han Mohammed Shahid Yuchi Han Walter R T Witschey |
author_sort |
Sebastian Berisha |
title |
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans. |
title_short |
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans. |
title_full |
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans. |
title_fullStr |
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans. |
title_full_unstemmed |
Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans. |
title_sort |
measurement of myocardial t1ρ with a motion corrected, parametric mapping sequence in humans. |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2016-01-01 |
description |
<h4>Purpose</h4>To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans.<h4>Materials and methods</h4>We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical flow-based image registration method was used to align T1ρ images. The reproducibility and accuracy of these methods was assessed in phantoms and 10 healthy subjects. Results are shown in 1 patient with pre-ventricular contractions (PVCs), 1 patient with chronic myocardial infarction (MI) and 2 patients with hypertrophic cardiomyopathy (HCM).<h4>Results</h4>In phantoms, the mean bias was 1.0 ± 2.7 msec (100 msec phantom) and 0.9 ± 0.9 msec (60 msec phantom) at 60 bpm and 2.2 ± 3.2 msec (100 msec) and 1.4 ± 0.9 msec (60 msec) at 80 bpm. The coefficient of variation (COV) was 2.2 (100 msec) and 1.3 (60 msec) at 60 bpm and 2.6 (100 msec) and 1.4 (60 msec) at 80 bpm. Motion correction improved the alignment of T1ρ images in subjects, as determined by the increase in Dice Score Coefficient (DSC) from 0.76 to 0.88. T1ρ reproducibility was high (COV < 0.05, intra-class correlation coefficient (ICC) = 0.85-0.97). Mean myocardial T1ρ value in healthy subjects was 63.5 ± 4.6 msec. There was good correspondence between late-gadolinium enhanced (LGE) MRI and increased T1ρ relaxation times in patients.<h4>Conclusion</h4>Single-shot, motion corrected, spin echo, spin lock MRI permits 2D T1ρ mapping in a breath-hold with good accuracy and precision. |
url |
https://doi.org/10.1371/journal.pone.0151144 |
work_keys_str_mv |
AT sebastianberisha measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans AT joycehan measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans AT mohammedshahid measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans AT yuchihan measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans AT walterrtwitschey measurementofmyocardialt1rwithamotioncorrectedparametricmappingsequenceinhumans |
_version_ |
1714803547866923008 |