X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents

In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the e...

Full description

Bibliographic Details
Main Authors: Alexander Chaplenko, Oksana Monogarova, Kirill Oskolok
Format: Article
Language:English
Published: College of Pharmacy University of Baghdad 2018-12-01
Series:Iraqi Journal of Pharmaceutical Sciences
Subjects:
Online Access:http://bijps.uobaghdad.edu.iq/index.php/bijps/article/view/762
id doaj-533b5b3a78c94a15b0fed68379d8a74a
record_format Article
spelling doaj-533b5b3a78c94a15b0fed68379d8a74a2020-11-24T22:01:25ZengCollege of Pharmacy University of BaghdadIraqi Journal of Pharmaceutical Sciences2521-35121683-35972018-12-011610.31351/vol27iss2pp1-6762X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam SorbentsAlexander Chaplenko0Oksana MonogarovaKirill OskolokLomonosov Moscow State UniversityIn this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral complexes («Alfavit», «Vitrum» and «Multi-tabs»).http://bijps.uobaghdad.edu.iq/index.php/bijps/article/view/762X-ray fluorescence analysistrace elementsmicroelementsvitamins
collection DOAJ
language English
format Article
sources DOAJ
author Alexander Chaplenko
Oksana Monogarova
Kirill Oskolok
spellingShingle Alexander Chaplenko
Oksana Monogarova
Kirill Oskolok
X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
Iraqi Journal of Pharmaceutical Sciences
X-ray fluorescence analysis
trace elements
microelements
vitamins
author_facet Alexander Chaplenko
Oksana Monogarova
Kirill Oskolok
author_sort Alexander Chaplenko
title X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
title_short X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
title_full X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
title_fullStr X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
title_full_unstemmed X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
title_sort x-ray fluorescence determination of trace elements in vitamin-mineral complexes and medicinal herbs using chemically modified polyurethane foam sorbents
publisher College of Pharmacy University of Baghdad
series Iraqi Journal of Pharmaceutical Sciences
issn 2521-3512
1683-3597
publishDate 2018-12-01
description In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral complexes («Alfavit», «Vitrum» and «Multi-tabs»).
topic X-ray fluorescence analysis
trace elements
microelements
vitamins
url http://bijps.uobaghdad.edu.iq/index.php/bijps/article/view/762
work_keys_str_mv AT alexanderchaplenko xrayfluorescencedeterminationoftraceelementsinvitaminmineralcomplexesandmedicinalherbsusingchemicallymodifiedpolyurethanefoamsorbents
AT oksanamonogarova xrayfluorescencedeterminationoftraceelementsinvitaminmineralcomplexesandmedicinalherbsusingchemicallymodifiedpolyurethanefoamsorbents
AT kirilloskolok xrayfluorescencedeterminationoftraceelementsinvitaminmineralcomplexesandmedicinalherbsusingchemicallymodifiedpolyurethanefoamsorbents
_version_ 1725839686378717184