Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging
Purpose: To describe and characterize fast-kV switching, dual-energy (DE) imaging implemented within the on-board imager of a commercial linear accelerator for markerless tumor tracking (MTT). Methods and Materials: Fast-kV switching, DE imaging provides for rapid switching between programmed tube v...
Main Authors: | , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-09-01
|
Series: | Advances in Radiation Oncology |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2452109420300294 |
id |
doaj-5320db351c5f4a0c87f83dc01dd74cf6 |
---|---|
record_format |
Article |
spelling |
doaj-5320db351c5f4a0c87f83dc01dd74cf62020-11-25T03:46:45ZengElsevierAdvances in Radiation Oncology2452-10942020-09-015510061013Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy ImagingJohn C. Roeske, PhD0Hassan Mostafavi, PhD1Maksat Haytmyradov, PhD2Adam Wang, PhD3Daniel Morf, BS4Luca Cortesi, MSc5Murat Surucu, PhD6Rakesh Patel, PhD7Roberto Cassetta, PhD8Liangjia Zhu, PhD9Mathias Lehmann, PhD10Matthew M. Harkenrider, MD11Department of Radiation Oncology, Loyola University Chicago, Maywood, Illinois; Corresponding author: John C. Roeske, PhDVarian Medical Systems, Palo Alto, CaliforniaDepartment of Radiation Oncology, Loyola University Chicago, Maywood, IllinoisVarian Medical Systems, Palo Alto, CaliforniaVarian Medical Systems, Palo Alto, CaliforniaVarian Medical Systems, Palo Alto, CaliforniaDepartment of Radiation Oncology, Loyola University Chicago, Maywood, IllinoisDepartment of Radiation Oncology, Loyola University Chicago, Maywood, IllinoisDepartment of Radiation Oncology, Loyola University Chicago, Maywood, IllinoisVarian Medical Systems, Palo Alto, CaliforniaVarian Medical Systems, Palo Alto, CaliforniaDepartment of Radiation Oncology, Loyola University Chicago, Maywood, IllinoisPurpose: To describe and characterize fast-kV switching, dual-energy (DE) imaging implemented within the on-board imager of a commercial linear accelerator for markerless tumor tracking (MTT). Methods and Materials: Fast-kV switching, DE imaging provides for rapid switching between programmed tube voltages (ie, 60 and 120 kVp) from one image frame to the next. To characterize this system, the weighting factor used for logarithmic subtraction and signal difference-to-noise ratio were analyzed as a function of time and frame rate. MTT was evaluated using a thorax motion phantom and fast kV, DE imaging was compared versus single energy (SE) imaging over 360 degrees of rotation. A template-based matching algorithm was used to track target motion on both DE and SE sequences. Receiver operating characteristics were used to compare tracking results for both modalities. Results: The weighting factor was inversely related to frame rate and stable over time. After applying the frame rate–dependent weighting factor, the signal difference-to-noise ratio was consistent across all frame rates considered for simulated tumors ranging from 5 to 25 mm in diameter. An analysis of receiver operating characteristics curves showed improved tracking with DE versus SE imaging. The area under the curve for the 10-mm target ranged from 0.821 to 0.858 for SE imaging versus 0.968 to 0.974 for DE imaging. Moreover, the residual tracking errors for the same target size ranged from 2.02 to 2.18 mm versus 0.79 to 1.07 mm for SE and DE imaging, respectively. Conclusions: Fast-kV switching, DE imaging was implemented on the on-board imager of a commercial linear accelerator. DE imaging resulted in improved MTT accuracy over SE imaging. Such an approach may have application for MTT of patients with lung cancer receiving stereotactic body radiation therapy, particularly for small tumors where MTT with SE imaging may fail.http://www.sciencedirect.com/science/article/pii/S2452109420300294 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
John C. Roeske, PhD Hassan Mostafavi, PhD Maksat Haytmyradov, PhD Adam Wang, PhD Daniel Morf, BS Luca Cortesi, MSc Murat Surucu, PhD Rakesh Patel, PhD Roberto Cassetta, PhD Liangjia Zhu, PhD Mathias Lehmann, PhD Matthew M. Harkenrider, MD |
spellingShingle |
John C. Roeske, PhD Hassan Mostafavi, PhD Maksat Haytmyradov, PhD Adam Wang, PhD Daniel Morf, BS Luca Cortesi, MSc Murat Surucu, PhD Rakesh Patel, PhD Roberto Cassetta, PhD Liangjia Zhu, PhD Mathias Lehmann, PhD Matthew M. Harkenrider, MD Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging Advances in Radiation Oncology |
author_facet |
John C. Roeske, PhD Hassan Mostafavi, PhD Maksat Haytmyradov, PhD Adam Wang, PhD Daniel Morf, BS Luca Cortesi, MSc Murat Surucu, PhD Rakesh Patel, PhD Roberto Cassetta, PhD Liangjia Zhu, PhD Mathias Lehmann, PhD Matthew M. Harkenrider, MD |
author_sort |
John C. Roeske, PhD |
title |
Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging |
title_short |
Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging |
title_full |
Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging |
title_fullStr |
Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging |
title_full_unstemmed |
Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging |
title_sort |
characterization of markerless tumor tracking using the on-board imager of a commercial linear accelerator equipped with fast-kv switching dual-energy imaging |
publisher |
Elsevier |
series |
Advances in Radiation Oncology |
issn |
2452-1094 |
publishDate |
2020-09-01 |
description |
Purpose: To describe and characterize fast-kV switching, dual-energy (DE) imaging implemented within the on-board imager of a commercial linear accelerator for markerless tumor tracking (MTT). Methods and Materials: Fast-kV switching, DE imaging provides for rapid switching between programmed tube voltages (ie, 60 and 120 kVp) from one image frame to the next. To characterize this system, the weighting factor used for logarithmic subtraction and signal difference-to-noise ratio were analyzed as a function of time and frame rate. MTT was evaluated using a thorax motion phantom and fast kV, DE imaging was compared versus single energy (SE) imaging over 360 degrees of rotation. A template-based matching algorithm was used to track target motion on both DE and SE sequences. Receiver operating characteristics were used to compare tracking results for both modalities. Results: The weighting factor was inversely related to frame rate and stable over time. After applying the frame rate–dependent weighting factor, the signal difference-to-noise ratio was consistent across all frame rates considered for simulated tumors ranging from 5 to 25 mm in diameter. An analysis of receiver operating characteristics curves showed improved tracking with DE versus SE imaging. The area under the curve for the 10-mm target ranged from 0.821 to 0.858 for SE imaging versus 0.968 to 0.974 for DE imaging. Moreover, the residual tracking errors for the same target size ranged from 2.02 to 2.18 mm versus 0.79 to 1.07 mm for SE and DE imaging, respectively. Conclusions: Fast-kV switching, DE imaging was implemented on the on-board imager of a commercial linear accelerator. DE imaging resulted in improved MTT accuracy over SE imaging. Such an approach may have application for MTT of patients with lung cancer receiving stereotactic body radiation therapy, particularly for small tumors where MTT with SE imaging may fail. |
url |
http://www.sciencedirect.com/science/article/pii/S2452109420300294 |
work_keys_str_mv |
AT johncroeskephd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT hassanmostafaviphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT maksathaytmyradovphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT adamwangphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT danielmorfbs characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT lucacortesimsc characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT muratsurucuphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT rakeshpatelphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT robertocassettaphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT liangjiazhuphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT mathiaslehmannphd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging AT matthewmharkenridermd characterizationofmarkerlesstumortrackingusingtheonboardimagerofacommerciallinearacceleratorequippedwithfastkvswitchingdualenergyimaging |
_version_ |
1724504393519202304 |