Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator

Background: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy® and Elekta Synergy®. This prevents most existing linacs from delivering VMAT. The purpose of this study was to investigate the feasibility of using a conventional line...

Full description

Bibliographic Details
Main Authors: Ruo-Hui Zhang, Xiao-Mei Fan, Wen-Wen Bai, Yan-Kun Cao
Format: Article
Language:English
Published: Wolters Kluwer 2016-01-01
Series:Chinese Medical Journal
Subjects:
Online Access:http://www.cmj.org/article.asp?issn=0366-6999;year=2016;volume=129;issue=3;spage=284;epage=288;aulast=Zhang
id doaj-52927e5409b54f2d9db7b57d4c53c299
record_format Article
spelling doaj-52927e5409b54f2d9db7b57d4c53c2992020-11-25T00:48:17ZengWolters KluwerChinese Medical Journal0366-69992016-01-01129328428810.4103/0366-6999.174500Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear AcceleratorRuo-Hui ZhangXiao-Mei FanWen-Wen BaiYan-Kun CaoBackground: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy® and Elekta Synergy®. This prevents most existing linacs from delivering VMAT. The purpose of this study was to investigate the feasibility of using a conventional linear accelerator delivering constant dose rate and constant angular spacing intensity-modulated arc therapy (CDR-CAS-IMAT) for treating cervical cancer. Methods: Twenty patients with cervical cancer previously treated with intensity-modulated radiation therapy (IMRT) using Varian Clinical 23EX were retreated using CDR-CAS-IMAT. The planning target volume (PTV) was set as 50.4 Gy in 28 fractions. Plans were evaluated based on the ability to meet the dose volume histogram. The homogeneity index (HI), target volume conformity index (CI), the dose to organs at risk, radiation delivery time, and monitor units (MUs) were also compared. The paired t-test was used to analyze the two data sets. All statistical analyses were performed using SPSS 19.0 software. Results: Compared to the IMRT group, the CDR-CAS-IMAT group showed better PTV CI (0.85 ± 0.03 vs. 0.81 ± 0.03, P = 0.001), clinical target volume CI (0.46 ± 0.05 vs. 0.43 ± 0.05, P = 0.001), HI (0.09±0.02 vs. 0.11 ± 0.02, P = 0.005) and D95 (5196.33 ± 28.24 cGy vs. 5162.63 ± 31.12 cGy, P = 0.000), and cord D2 (3743.8 ± 118.7 cGy vs. 3806.2 ± 98.7 cGy, P = 0.017) and rectum V40 (41.9 ± 6.1% vs. 44.2 ± 4.8%, P = 0.026). Treatment time (422.7 ± 46.7 s vs. 84.6 ± 7.8 s, P = 0.000) and the total plan Mus (927.4 ± 79.1 vs. 787.5 ± 78.5, P = 0.000) decreased by a factor of 0.8 and 0.15, respectively. The IMRT group plans were superior to the CDR-CAS-IMAT group plans considering decreasing bladder V50 (17.4 ± 4.5% vs. 16.6 ± 4.2%, P = 0.049), bowel V30 (39.6 ± 6.5% vs. 36.6 ± 7.5%, P = 0.008), and low-dose irradiation volume; there were no significant differences in other statistical indexes. Conclusions: Patients with cervical cancer treated with CDR-CAS-IMAT using Varian Clinical 23EX can get equivalent or superior dose distribution compared to those treated with IMRT. CDR-CAS-IMAT has a less treatment time and MU, which can reduce the uncertainty factor and patient discomfort in treatment.http://www.cmj.org/article.asp?issn=0366-6999;year=2016;volume=129;issue=3;spage=284;epage=288;aulast=ZhangCervical Cancer; Constant Angular Space; Constant Dose Rate; Dosimetry; Intensity-modulated Arc Therapy; Intensity-modulated Radiation Therapy
collection DOAJ
language English
format Article
sources DOAJ
author Ruo-Hui Zhang
Xiao-Mei Fan
Wen-Wen Bai
Yan-Kun Cao
spellingShingle Ruo-Hui Zhang
Xiao-Mei Fan
Wen-Wen Bai
Yan-Kun Cao
Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator
Chinese Medical Journal
Cervical Cancer; Constant Angular Space; Constant Dose Rate; Dosimetry; Intensity-modulated Arc Therapy; Intensity-modulated Radiation Therapy
author_facet Ruo-Hui Zhang
Xiao-Mei Fan
Wen-Wen Bai
Yan-Kun Cao
author_sort Ruo-Hui Zhang
title Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator
title_short Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator
title_full Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator
title_fullStr Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator
title_full_unstemmed Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator
title_sort implementation of constant dose rate and constant angular spacing intensity-modulated arc therapy for cervical cancer by using a conventional linear accelerator
publisher Wolters Kluwer
series Chinese Medical Journal
issn 0366-6999
publishDate 2016-01-01
description Background: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy® and Elekta Synergy®. This prevents most existing linacs from delivering VMAT. The purpose of this study was to investigate the feasibility of using a conventional linear accelerator delivering constant dose rate and constant angular spacing intensity-modulated arc therapy (CDR-CAS-IMAT) for treating cervical cancer. Methods: Twenty patients with cervical cancer previously treated with intensity-modulated radiation therapy (IMRT) using Varian Clinical 23EX were retreated using CDR-CAS-IMAT. The planning target volume (PTV) was set as 50.4 Gy in 28 fractions. Plans were evaluated based on the ability to meet the dose volume histogram. The homogeneity index (HI), target volume conformity index (CI), the dose to organs at risk, radiation delivery time, and monitor units (MUs) were also compared. The paired t-test was used to analyze the two data sets. All statistical analyses were performed using SPSS 19.0 software. Results: Compared to the IMRT group, the CDR-CAS-IMAT group showed better PTV CI (0.85 ± 0.03 vs. 0.81 ± 0.03, P = 0.001), clinical target volume CI (0.46 ± 0.05 vs. 0.43 ± 0.05, P = 0.001), HI (0.09±0.02 vs. 0.11 ± 0.02, P = 0.005) and D95 (5196.33 ± 28.24 cGy vs. 5162.63 ± 31.12 cGy, P = 0.000), and cord D2 (3743.8 ± 118.7 cGy vs. 3806.2 ± 98.7 cGy, P = 0.017) and rectum V40 (41.9 ± 6.1% vs. 44.2 ± 4.8%, P = 0.026). Treatment time (422.7 ± 46.7 s vs. 84.6 ± 7.8 s, P = 0.000) and the total plan Mus (927.4 ± 79.1 vs. 787.5 ± 78.5, P = 0.000) decreased by a factor of 0.8 and 0.15, respectively. The IMRT group plans were superior to the CDR-CAS-IMAT group plans considering decreasing bladder V50 (17.4 ± 4.5% vs. 16.6 ± 4.2%, P = 0.049), bowel V30 (39.6 ± 6.5% vs. 36.6 ± 7.5%, P = 0.008), and low-dose irradiation volume; there were no significant differences in other statistical indexes. Conclusions: Patients with cervical cancer treated with CDR-CAS-IMAT using Varian Clinical 23EX can get equivalent or superior dose distribution compared to those treated with IMRT. CDR-CAS-IMAT has a less treatment time and MU, which can reduce the uncertainty factor and patient discomfort in treatment.
topic Cervical Cancer; Constant Angular Space; Constant Dose Rate; Dosimetry; Intensity-modulated Arc Therapy; Intensity-modulated Radiation Therapy
url http://www.cmj.org/article.asp?issn=0366-6999;year=2016;volume=129;issue=3;spage=284;epage=288;aulast=Zhang
work_keys_str_mv AT ruohuizhang implementationofconstantdoserateandconstantangularspacingintensitymodulatedarctherapyforcervicalcancerbyusingaconventionallinearaccelerator
AT xiaomeifan implementationofconstantdoserateandconstantangularspacingintensitymodulatedarctherapyforcervicalcancerbyusingaconventionallinearaccelerator
AT wenwenbai implementationofconstantdoserateandconstantangularspacingintensitymodulatedarctherapyforcervicalcancerbyusingaconventionallinearaccelerator
AT yankuncao implementationofconstantdoserateandconstantangularspacingintensitymodulatedarctherapyforcervicalcancerbyusingaconventionallinearaccelerator
_version_ 1725256980734410752