The initial stability of dental implant with horizontal plate (An in vitro study)

Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torqu...

Full description

Bibliographic Details
Main Authors: Yaseen H Motea, Basima MA Hussein
Format: Article
Language:English
Published: College of Dentistry/ University of Baghdad 2014-12-01
Series:Journal of Baghdad College of Dentistry
Online Access:https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/597
id doaj-5292735a358544c5b7cdf9fe59ef67fc
record_format Article
spelling doaj-5292735a358544c5b7cdf9fe59ef67fc2021-09-02T21:04:12ZengCollege of Dentistry/ University of BaghdadJournal of Baghdad College of Dentistry2311-52702014-12-01264The initial stability of dental implant with horizontal plate (An in vitro study)Yaseen H MoteaBasima MA HusseinBackground: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial stability of dental implants’ design was compared with initial stability of dental implants of the same dimensions and design that engage horizontal plates of 1.5mm thickness at the apical part. All dental implants were implanted into a solid rigid polyurethane foam blocks (artificial bone) of 0.48g/cm3 density and tested by the five initial stability tests. Each test was done with forty samples (twenty samples of 5mm length and twenty samples of 10mm length). Results: The statistical analysis was performed and the result showed that there was very highly significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both 5mm and 10 mm lengths in four initial stability tests which were insertion torque, removal torque, push-in test and pull-out test. The statistical analysis of the resonance frequency analysis showed that there was non-significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both lengths. Conclusion: These results implied that the dental implants with the horizontal plates had better primary stability compared with the dental implants without the horizontal plates confirming that the horizontal plates enhanced the primary stability of the dental implants. https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/597
collection DOAJ
language English
format Article
sources DOAJ
author Yaseen H Motea
Basima MA Hussein
spellingShingle Yaseen H Motea
Basima MA Hussein
The initial stability of dental implant with horizontal plate (An in vitro study)
Journal of Baghdad College of Dentistry
author_facet Yaseen H Motea
Basima MA Hussein
author_sort Yaseen H Motea
title The initial stability of dental implant with horizontal plate (An in vitro study)
title_short The initial stability of dental implant with horizontal plate (An in vitro study)
title_full The initial stability of dental implant with horizontal plate (An in vitro study)
title_fullStr The initial stability of dental implant with horizontal plate (An in vitro study)
title_full_unstemmed The initial stability of dental implant with horizontal plate (An in vitro study)
title_sort initial stability of dental implant with horizontal plate (an in vitro study)
publisher College of Dentistry/ University of Baghdad
series Journal of Baghdad College of Dentistry
issn 2311-5270
publishDate 2014-12-01
description Background: The Initial (primary) stability is one of the factors that play an important role in the success of the dental implants. The purpose of this study was to evaluate the initial stability of dental implant with horizontal plate by using five analytical tests: insertion torque, removal torque, resonance frequency analysis, push-in test and pull-out test. Materials and methods: Two different lengths of dental implants (5mm and 10mm) were tested in this study; each dental implant was 4mm in diameter with a square threads shape of 1mm pitch and 0.5mm depth. The crestal area was 4.2mm diameter contained a right angle margin circumferential ring while the apical area was tapered with two self-tapping grooves. In this study, the initial stability of dental implants’ design was compared with initial stability of dental implants of the same dimensions and design that engage horizontal plates of 1.5mm thickness at the apical part. All dental implants were implanted into a solid rigid polyurethane foam blocks (artificial bone) of 0.48g/cm3 density and tested by the five initial stability tests. Each test was done with forty samples (twenty samples of 5mm length and twenty samples of 10mm length). Results: The statistical analysis was performed and the result showed that there was very highly significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both 5mm and 10 mm lengths in four initial stability tests which were insertion torque, removal torque, push-in test and pull-out test. The statistical analysis of the resonance frequency analysis showed that there was non-significant difference between dental implants with the horizontal plates and dental implants without the horizontal plates of both lengths. Conclusion: These results implied that the dental implants with the horizontal plates had better primary stability compared with the dental implants without the horizontal plates confirming that the horizontal plates enhanced the primary stability of the dental implants.
url https://jbcd.uobaghdad.edu.iq/index.php/jbcd/article/view/597
work_keys_str_mv AT yaseenhmotea theinitialstabilityofdentalimplantwithhorizontalplateaninvitrostudy
AT basimamahussein theinitialstabilityofdentalimplantwithhorizontalplateaninvitrostudy
AT yaseenhmotea initialstabilityofdentalimplantwithhorizontalplateaninvitrostudy
AT basimamahussein initialstabilityofdentalimplantwithhorizontalplateaninvitrostudy
_version_ 1721169793510277120