Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive

Statement of Problem: Blood contamination is a common problem in dentistry that can decrease bond strength dramatically which may be affected by methods of decontamination as well. Purpose: The aim of this study was to evaluate and compare the influence of blood contamination on shear bond strength...

Full description

Bibliographic Details
Main Authors: Mortazavi V., Fathi MH., Ajami AA
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2005-06-01
Series:Journal of Dental Medicine
Subjects:
Online Access:http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/1928.pdf&manuscript_id=1928
id doaj-52008d3865c243a8a87462af65cecfe6
record_format Article
spelling doaj-52008d3865c243a8a87462af65cecfe62020-11-24T21:12:13ZfasTehran University of Medical SciencesJournal of Dental Medicine1024-641X2008-24442005-06-011823543Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesiveMortazavi V.Fathi MH.Ajami AAStatement of Problem: Blood contamination is a common problem in dentistry that can decrease bond strength dramatically which may be affected by methods of decontamination as well. Purpose: The aim of this study was to evaluate and compare the influence of blood contamination on shear bond strength of composite and compomer to dentin using Prompt L-Pop as an adhesive system. Also, to assess the effectiveness of different surface treatments on the bond strength. Materials and Methods: In this experimental study, 120 molar teeth were sectioned to provide flat occlusal dentinal surfaces. Specimens were embedded in acrylic resin with the flat surface exposed. The dentinal expose surfaces were polished to 600 grit. The teeth were randomly divided into five groups of twelve specimens (F1–F5) for compomer material and five other groups (Z1- Z5) for composite resin. After application of Promt L-Pop to dentinal surfaces of specimens, the surfaces in all groups, except for F1 and Z1, (as controls) were contaminated with human blood and then one of the following surface treatments was applied. Groups F2 and Z2 without any treatment, groups F3 and Z3 rinsing with water, groups F4 and Z4 rinsing with water and reapplication of adhesive, groups F5 and Z5 rinsing with NaOCl and using Prompt L-Pop again. Restorative materials were applied to treated surfaces using plastic molds. After thermocycling, shear bond strengths, mode of failures and morphology of dentin-material interfaces were evaluated. The data were statistically analyzed using Factorial analysis of Variance, One-Way ANOVA, Duncan, T-student and Chi-Square tests with P<0.05 as the limit of significance. Results: Compomer showed statistically significant higher bond strength in comparison to composite (P<0.001). Duncan test showed significant differences between all compomer groups, except between groups F4 and F5, and between all composite groups except for groups Z1 and Z4 and for groups Z2 and Z3. Conclusion: Based on the findings of this study, shear bond strength of compomer material was significantly higher than composite. Blood contamination reduced bond strength, but rinsing contaminated dentin with water or NaOCl and reusing Prompt L-Pop increased bond strength in both materials. http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/1928.pdf&manuscript_id=1928Blood contaminationPrompt L-Pop, Composite resinCompomer
collection DOAJ
language fas
format Article
sources DOAJ
author Mortazavi V.
Fathi MH.
Ajami AA
spellingShingle Mortazavi V.
Fathi MH.
Ajami AA
Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
Journal of Dental Medicine
Blood contamination
Prompt L-Pop, Composite resin
Compomer
author_facet Mortazavi V.
Fathi MH.
Ajami AA
author_sort Mortazavi V.
title Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
title_short Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
title_full Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
title_fullStr Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
title_full_unstemmed Effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
title_sort effect of different blood contaminated adherent surface treatments on shear bond strength of compomer and composite resin to dentin, using a self etching adhesive
publisher Tehran University of Medical Sciences
series Journal of Dental Medicine
issn 1024-641X
2008-2444
publishDate 2005-06-01
description Statement of Problem: Blood contamination is a common problem in dentistry that can decrease bond strength dramatically which may be affected by methods of decontamination as well. Purpose: The aim of this study was to evaluate and compare the influence of blood contamination on shear bond strength of composite and compomer to dentin using Prompt L-Pop as an adhesive system. Also, to assess the effectiveness of different surface treatments on the bond strength. Materials and Methods: In this experimental study, 120 molar teeth were sectioned to provide flat occlusal dentinal surfaces. Specimens were embedded in acrylic resin with the flat surface exposed. The dentinal expose surfaces were polished to 600 grit. The teeth were randomly divided into five groups of twelve specimens (F1–F5) for compomer material and five other groups (Z1- Z5) for composite resin. After application of Promt L-Pop to dentinal surfaces of specimens, the surfaces in all groups, except for F1 and Z1, (as controls) were contaminated with human blood and then one of the following surface treatments was applied. Groups F2 and Z2 without any treatment, groups F3 and Z3 rinsing with water, groups F4 and Z4 rinsing with water and reapplication of adhesive, groups F5 and Z5 rinsing with NaOCl and using Prompt L-Pop again. Restorative materials were applied to treated surfaces using plastic molds. After thermocycling, shear bond strengths, mode of failures and morphology of dentin-material interfaces were evaluated. The data were statistically analyzed using Factorial analysis of Variance, One-Way ANOVA, Duncan, T-student and Chi-Square tests with P<0.05 as the limit of significance. Results: Compomer showed statistically significant higher bond strength in comparison to composite (P<0.001). Duncan test showed significant differences between all compomer groups, except between groups F4 and F5, and between all composite groups except for groups Z1 and Z4 and for groups Z2 and Z3. Conclusion: Based on the findings of this study, shear bond strength of compomer material was significantly higher than composite. Blood contamination reduced bond strength, but rinsing contaminated dentin with water or NaOCl and reusing Prompt L-Pop increased bond strength in both materials.
topic Blood contamination
Prompt L-Pop, Composite resin
Compomer
url http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/1928.pdf&manuscript_id=1928
work_keys_str_mv AT mortazaviv effectofdifferentbloodcontaminatedadherentsurfacetreatmentsonshearbondstrengthofcompomerandcompositeresintodentinusingaselfetchingadhesive
AT fathimh effectofdifferentbloodcontaminatedadherentsurfacetreatmentsonshearbondstrengthofcompomerandcompositeresintodentinusingaselfetchingadhesive
AT ajamiaa effectofdifferentbloodcontaminatedadherentsurfacetreatmentsonshearbondstrengthofcompomerandcompositeresintodentinusingaselfetchingadhesive
_version_ 1716751205046157312