Constant Temperature Anemometer with Self-Calibration Closed Loop Circuit

In this paper, a Micro-Electro-Mechanical Systems (MEMS) calorimetric sensor with its measurement electronics is designed, fabricated, and tested. The idea is to apply a configurable voltage to the sensitive resistor and measure the current flowing through the heating resistor using a current mirror...

Full description

Bibliographic Details
Main Authors: Jamel Nebhen, Khaled Alnowaiser, Sofiene Mansouri
Format: Article
Language:English
Published: MDPI AG 2020-05-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/10/10/3405