Reliability of the radiographic union scale in tibial fractures (RUST)
ABSTRACT OBJECTIVE: This study aimed to evaluate the inter- and intra observer reproducibility of the radiographic score of consolidation of the tibia shaft fractures. METHODS: Fifty-one sets of radiographs in anteroposterior (AP) and profile (P) of the tibial shaft treated with intramedullary n...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Ortopedia e Traumatologia
|
Series: | Revista Brasileira de Ortopedia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162017000100035&lng=en&tlng=en |
id |
doaj-5117f0be6052496c8413f1c6c0cd3b83 |
---|---|
record_format |
Article |
spelling |
doaj-5117f0be6052496c8413f1c6c0cd3b832020-11-24T23:36:29ZengSociedade Brasileira de Ortopedia e TraumatologiaRevista Brasileira de Ortopedia1982-4378521353910.1016/j.rboe.2016.05.006S0102-36162017000100035Reliability of the radiographic union scale in tibial fractures (RUST)Fernando Antonio Silva de Azevedo FilhoRicardo Britto CotiasMatheus Lemos AziArmando Augusto de Almeida TeixeiraABSTRACT OBJECTIVE: This study aimed to evaluate the inter- and intra observer reproducibility of the radiographic score of consolidation of the tibia shaft fractures. METHODS: Fifty-one sets of radiographs in anteroposterior (AP) and profile (P) of the tibial shaft treated with intramedullary nail were obtained. The analysis of X-rays was performed in two stages, with a 21-day interval between assessments by a group of nine evaluators. To evaluate the reproducibility of RUST score between the evaluators, the intra-class correlation coefficient (ICC) with a 95% confidence interval was used. ICC values range from +1, representing perfect agreement, to -1, complete disagreement. RESULTS: There was a significant correlation among all evaluators: ICC = 0.87 (95% CI 0.81 to 0.91). The intraobserver agreement proved to be substantial with ICC = 0.88 (95% CI 0.85 to 0.91) . CONCLUSION: This study confirms that the RUST scale shows a high degree of reliability and agreement.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162017000100035&lng=en&tlng=enTibiaFracture healingRadiography |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Fernando Antonio Silva de Azevedo Filho Ricardo Britto Cotias Matheus Lemos Azi Armando Augusto de Almeida Teixeira |
spellingShingle |
Fernando Antonio Silva de Azevedo Filho Ricardo Britto Cotias Matheus Lemos Azi Armando Augusto de Almeida Teixeira Reliability of the radiographic union scale in tibial fractures (RUST) Revista Brasileira de Ortopedia Tibia Fracture healing Radiography |
author_facet |
Fernando Antonio Silva de Azevedo Filho Ricardo Britto Cotias Matheus Lemos Azi Armando Augusto de Almeida Teixeira |
author_sort |
Fernando Antonio Silva de Azevedo Filho |
title |
Reliability of the radiographic union scale in tibial fractures (RUST) |
title_short |
Reliability of the radiographic union scale in tibial fractures (RUST) |
title_full |
Reliability of the radiographic union scale in tibial fractures (RUST) |
title_fullStr |
Reliability of the radiographic union scale in tibial fractures (RUST) |
title_full_unstemmed |
Reliability of the radiographic union scale in tibial fractures (RUST) |
title_sort |
reliability of the radiographic union scale in tibial fractures (rust) |
publisher |
Sociedade Brasileira de Ortopedia e Traumatologia |
series |
Revista Brasileira de Ortopedia |
issn |
1982-4378 |
description |
ABSTRACT OBJECTIVE: This study aimed to evaluate the inter- and intra observer reproducibility of the radiographic score of consolidation of the tibia shaft fractures. METHODS: Fifty-one sets of radiographs in anteroposterior (AP) and profile (P) of the tibial shaft treated with intramedullary nail were obtained. The analysis of X-rays was performed in two stages, with a 21-day interval between assessments by a group of nine evaluators. To evaluate the reproducibility of RUST score between the evaluators, the intra-class correlation coefficient (ICC) with a 95% confidence interval was used. ICC values range from +1, representing perfect agreement, to -1, complete disagreement. RESULTS: There was a significant correlation among all evaluators: ICC = 0.87 (95% CI 0.81 to 0.91). The intraobserver agreement proved to be substantial with ICC = 0.88 (95% CI 0.85 to 0.91) . CONCLUSION: This study confirms that the RUST scale shows a high degree of reliability and agreement. |
topic |
Tibia Fracture healing Radiography |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162017000100035&lng=en&tlng=en |
work_keys_str_mv |
AT fernandoantoniosilvadeazevedofilho reliabilityoftheradiographicunionscaleintibialfracturesrust AT ricardobrittocotias reliabilityoftheradiographicunionscaleintibialfracturesrust AT matheuslemosazi reliabilityoftheradiographicunionscaleintibialfracturesrust AT armandoaugustodealmeidateixeira reliabilityoftheradiographicunionscaleintibialfracturesrust |
_version_ |
1725523344201089024 |