Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard
The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear loa...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-11-01
|
Series: | Materials |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1944/13/21/4938 |
id |
doaj-50c8e38c4c5a4afcb2c5c8aaaf8d6be8 |
---|---|
record_format |
Article |
spelling |
doaj-50c8e38c4c5a4afcb2c5c8aaaf8d6be82020-11-25T04:08:08ZengMDPI AGMaterials1996-19442020-11-01134938493810.3390/ma13214938Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 StandardMaciej Grabski0Andrzej Ambroziak1Faculty of Civil and Environmental Engineering, Gdansk University of Technology, 11/12 Gabriela Narutowicza Street, 80-233 Gdańsk, PolandFaculty of Civil and Environmental Engineering, Gdansk University of Technology, 11/12 Gabriela Narutowicza Street, 80-233 Gdańsk, PolandThe scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps.https://www.mdpi.com/1996-1944/13/21/4938reinforced concreteslab-column connectionspunching shearshear capshear head. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Maciej Grabski Andrzej Ambroziak |
spellingShingle |
Maciej Grabski Andrzej Ambroziak Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard Materials reinforced concrete slab-column connections punching shear shear cap shear head. |
author_facet |
Maciej Grabski Andrzej Ambroziak |
author_sort |
Maciej Grabski |
title |
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_short |
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_full |
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_fullStr |
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_full_unstemmed |
Shear Cap Size Selection Method Based on Parametric Analysis of ACI-318 Code and Eurocode 2 Standard |
title_sort |
shear cap size selection method based on parametric analysis of aci-318 code and eurocode 2 standard |
publisher |
MDPI AG |
series |
Materials |
issn |
1996-1944 |
publishDate |
2020-11-01 |
description |
The scope of the paper is to propose a method for determining the size of shear caps in a slab–column-connections-reinforced concrete structure. Usually, shear heads are used to enhance slab–column connection, especially when the transverse reinforcement does not give the required punching shear load capacity. The dimensions of the shear head should provide the punching shear resistance of the connection inside and outside the enhanced region. The process of selecting the size of the shear head is iterative. The parametric analysis of the ACI 318 code and EC2 standard has the objective of indicating which control perimeter (inside or outside the shear head) has a decisive impact on the punching shear capacity of the connection. Based on the analysis, the authors propose methods for selecting the dimensions of the shear head with practical application examples. The paper is intended to provide scientists, civil engineers, and designers with guidelines to design the process of the slab–column connections with the shear caps. |
topic |
reinforced concrete slab-column connections punching shear shear cap shear head. |
url |
https://www.mdpi.com/1996-1944/13/21/4938 |
work_keys_str_mv |
AT maciejgrabski shearcapsizeselectionmethodbasedonparametricanalysisofaci318codeandeurocode2standard AT andrzejambroziak shearcapsizeselectionmethodbasedonparametricanalysisofaci318codeandeurocode2standard |
_version_ |
1724426650468220928 |