TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES

The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological an...

Full description

Bibliographic Details
Main Authors: A. E. Denysova, G. V. Luzhanska, I. O. Bodnar, A. S. Denysova
Format: Article
Language:English
Published: Odessa National Academy of Food Technologies 2017-09-01
Series:Holodilʹnaâ Tehnika i Tehnologiâ
Subjects:
Online Access:http://journals.gsjp.eu/index.php/reftech/article/view/539
id doaj-5093812e089e41e086bacee7a3a72669
record_format Article
spelling doaj-5093812e089e41e086bacee7a3a726692020-11-24T23:48:13ZengOdessa National Academy of Food TechnologiesHolodilʹnaâ Tehnika i Tehnologiâ0453-83072409-67922017-09-0153110.15673/ret.v53i1.539496TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIESA. E. Denysova0G. V. Luzhanska1I. O. Bodnar2A. S. Denysova3Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.http://journals.gsjp.eu/index.php/reftech/article/view/539Heating LoadingFreonTwo Stages Heat Pump InstallationLow-Potential Source of HeatEnergy Efficiency
collection DOAJ
language English
format Article
sources DOAJ
author A. E. Denysova
G. V. Luzhanska
I. O. Bodnar
A. S. Denysova
spellingShingle A. E. Denysova
G. V. Luzhanska
I. O. Bodnar
A. S. Denysova
TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
Holodilʹnaâ Tehnika i Tehnologiâ
Heating Loading
Freon
Two Stages Heat Pump Installation
Low-Potential Source of Heat
Energy Efficiency
author_facet A. E. Denysova
G. V. Luzhanska
I. O. Bodnar
A. S. Denysova
author_sort A. E. Denysova
title TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
title_short TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
title_full TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
title_fullStr TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
title_full_unstemmed TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
title_sort two-stage heat pumps for energy saving technologies
publisher Odessa National Academy of Food Technologies
series Holodilʹnaâ Tehnika i Tehnologiâ
issn 0453-8307
2409-6792
publishDate 2017-09-01
description The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.
topic Heating Loading
Freon
Two Stages Heat Pump Installation
Low-Potential Source of Heat
Energy Efficiency
url http://journals.gsjp.eu/index.php/reftech/article/view/539
work_keys_str_mv AT aedenysova twostageheatpumpsforenergysavingtechnologies
AT gvluzhanska twostageheatpumpsforenergysavingtechnologies
AT iobodnar twostageheatpumpsforenergysavingtechnologies
AT asdenysova twostageheatpumpsforenergysavingtechnologies
_version_ 1725486729879617536