TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES
The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological an...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Odessa National Academy of Food Technologies
2017-09-01
|
Series: | Holodilʹnaâ Tehnika i Tehnologiâ |
Subjects: | |
Online Access: | http://journals.gsjp.eu/index.php/reftech/article/view/539 |
id |
doaj-5093812e089e41e086bacee7a3a72669 |
---|---|
record_format |
Article |
spelling |
doaj-5093812e089e41e086bacee7a3a726692020-11-24T23:48:13ZengOdessa National Academy of Food TechnologiesHolodilʹnaâ Tehnika i Tehnologiâ0453-83072409-67922017-09-0153110.15673/ret.v53i1.539496TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIESA. E. Denysova0G. V. Luzhanska1I. O. Bodnar2A. S. Denysova3Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044Odessa National Polytechnic University, av.Shevchenko, 1, Odessa, 65044The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.http://journals.gsjp.eu/index.php/reftech/article/view/539Heating LoadingFreonTwo Stages Heat Pump InstallationLow-Potential Source of HeatEnergy Efficiency |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A. E. Denysova G. V. Luzhanska I. O. Bodnar A. S. Denysova |
spellingShingle |
A. E. Denysova G. V. Luzhanska I. O. Bodnar A. S. Denysova TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES Holodilʹnaâ Tehnika i Tehnologiâ Heating Loading Freon Two Stages Heat Pump Installation Low-Potential Source of Heat Energy Efficiency |
author_facet |
A. E. Denysova G. V. Luzhanska I. O. Bodnar A. S. Denysova |
author_sort |
A. E. Denysova |
title |
TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES |
title_short |
TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES |
title_full |
TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES |
title_fullStr |
TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES |
title_full_unstemmed |
TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES |
title_sort |
two-stage heat pumps for energy saving technologies |
publisher |
Odessa National Academy of Food Technologies |
series |
Holodilʹnaâ Tehnika i Tehnologiâ |
issn |
0453-8307 2409-6792 |
publishDate |
2017-09-01 |
description |
The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations. |
topic |
Heating Loading Freon Two Stages Heat Pump Installation Low-Potential Source of Heat Energy Efficiency |