Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations

Background Recently, event-related potentials (ERPs) evoked by skin puncture, commonly used for blood sampling, have received attention as a pain assessment tool in neonates. However, their latency appears to be far shorter than the latency of ERPs evoked by intraepidermal electrical stimulation (IE...

Full description

Bibliographic Details
Main Authors: Yui Shiroshita, Hikari Kirimoto, Tatsunori Watanabe, Keisuke Yunoki, Ikuko Sobue
Format: Article
Language:English
Published: PeerJ Inc. 2021-10-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/12250.pdf
id doaj-50334d2218824a66977c5820f350d561
record_format Article
spelling doaj-50334d2218824a66977c5820f350d5612021-10-10T15:05:09ZengPeerJ Inc.PeerJ2167-83592021-10-019e1225010.7717/peerj.12250Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulationsYui Shiroshita0Hikari Kirimoto1Tatsunori Watanabe2Keisuke Yunoki3Ikuko Sobue4Department of Nursing Science, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, JapanDepartment of Sensorimotor Neuroscience, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, JapanDepartment of Sensorimotor Neuroscience, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, JapanDepartment of Sensorimotor Neuroscience, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, JapanDepartment of Nursing Science, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, JapanBackground Recently, event-related potentials (ERPs) evoked by skin puncture, commonly used for blood sampling, have received attention as a pain assessment tool in neonates. However, their latency appears to be far shorter than the latency of ERPs evoked by intraepidermal electrical stimulation (IES), which selectively activates nociceptive Aδ and C fibers. To clarify this important issue, we examined whether ERPs evoked by skin puncture appropriately reflect central nociceptive processing, as is the case with IES. Methods In Experiment 1, we recorded evoked potentials to the click sound produced by a lance device (click-only), lance stimulation with the click sound (click+lance), or lance stimulation with white noise (WN+lance) in eight healthy adults to investigate the effect of the click sound on the ERP evoked by skin puncture. In Experiment 2, we tested 18 heathy adults and recorded evoked potentials to shallow lance stimulation (SL) with a blade that did not reach the dermis (0.1 mm insertion depth); normal lance stimulation (CL) (1 mm depth); transcutaneous electrical stimulation (ES), which mainly activates Aβ fibers; and IES, which selectively activates Aδ fibers when low stimulation current intensities are applied. White noise was continuously presented during the experiments. The stimulations were applied to the hand dorsum. In the SL, the lance device did not touch the skin and the blade was inserted to a depth of 0.1 mm into the epidermis, where the free nerve endings of Aδ fibers are located, which minimized the tactile sensation caused by the device touching the skin and the activation of Aβ fibers by the blade reaching the dermis. In the CL, as in clinical use, the lance device touched the skin and the blade reached a depth of 1 mm from the skin surface, i.e., the depth of the dermis at which the Aβ fibers are located. Results The ERP N2 latencies for click-only (122 ± 2.9 ms) and click+lance (121 ± 6.5 ms) were significantly shorter than that for WN+lance (154 ± 7.1 ms). The ERP P2 latency for click-only (191 ± 11.3 ms) was significantly shorter than those for click+lance (249 ± 18.6 ms) and WN+lance (253 ± 11.2 ms). This suggests that the click sound shortens the N2 latency of the ERP evoked by skin puncture. The ERP N2 latencies for SL, CL, ES, and IES were 146 ± 8.3, 149 ± 9.9, 148 ± 13.1, and 197 ± 21.2 ms, respectively. The ERP P2 latencies were 250 ± 18.2, 251 ± 14.1, 237 ± 26.3, and 294 ± 30.0 ms, respectively. The ERP latency for SL was significantly shorter than that for IES and was similar to that for ES. This suggests that the penetration force generated by the blade of the lance device activates the Aβ fibers, consequently shortening the ERP latency. Conclusions Lance ERP may reflect the activation of Aβ fibers rather than Aδ fibers. A pain index that correctly and reliably reflects nociceptive processing must be developed to improve pain assessment and management in neonates.https://peerj.com/articles/12250.pdfSkin puncture (lance)Blood samplingPainNociceptive processingEvent-related potentialsAβ fibers
collection DOAJ
language English
format Article
sources DOAJ
author Yui Shiroshita
Hikari Kirimoto
Tatsunori Watanabe
Keisuke Yunoki
Ikuko Sobue
spellingShingle Yui Shiroshita
Hikari Kirimoto
Tatsunori Watanabe
Keisuke Yunoki
Ikuko Sobue
Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
PeerJ
Skin puncture (lance)
Blood sampling
Pain
Nociceptive processing
Event-related potentials
Aβ fibers
author_facet Yui Shiroshita
Hikari Kirimoto
Tatsunori Watanabe
Keisuke Yunoki
Ikuko Sobue
author_sort Yui Shiroshita
title Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
title_short Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
title_full Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
title_fullStr Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
title_full_unstemmed Event-related potentials evoked by skin puncture reflect activation of Aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
title_sort event-related potentials evoked by skin puncture reflect activation of aβ fibers: comparison with intraepidermal and transcutaneous electrical stimulations
publisher PeerJ Inc.
series PeerJ
issn 2167-8359
publishDate 2021-10-01
description Background Recently, event-related potentials (ERPs) evoked by skin puncture, commonly used for blood sampling, have received attention as a pain assessment tool in neonates. However, their latency appears to be far shorter than the latency of ERPs evoked by intraepidermal electrical stimulation (IES), which selectively activates nociceptive Aδ and C fibers. To clarify this important issue, we examined whether ERPs evoked by skin puncture appropriately reflect central nociceptive processing, as is the case with IES. Methods In Experiment 1, we recorded evoked potentials to the click sound produced by a lance device (click-only), lance stimulation with the click sound (click+lance), or lance stimulation with white noise (WN+lance) in eight healthy adults to investigate the effect of the click sound on the ERP evoked by skin puncture. In Experiment 2, we tested 18 heathy adults and recorded evoked potentials to shallow lance stimulation (SL) with a blade that did not reach the dermis (0.1 mm insertion depth); normal lance stimulation (CL) (1 mm depth); transcutaneous electrical stimulation (ES), which mainly activates Aβ fibers; and IES, which selectively activates Aδ fibers when low stimulation current intensities are applied. White noise was continuously presented during the experiments. The stimulations were applied to the hand dorsum. In the SL, the lance device did not touch the skin and the blade was inserted to a depth of 0.1 mm into the epidermis, where the free nerve endings of Aδ fibers are located, which minimized the tactile sensation caused by the device touching the skin and the activation of Aβ fibers by the blade reaching the dermis. In the CL, as in clinical use, the lance device touched the skin and the blade reached a depth of 1 mm from the skin surface, i.e., the depth of the dermis at which the Aβ fibers are located. Results The ERP N2 latencies for click-only (122 ± 2.9 ms) and click+lance (121 ± 6.5 ms) were significantly shorter than that for WN+lance (154 ± 7.1 ms). The ERP P2 latency for click-only (191 ± 11.3 ms) was significantly shorter than those for click+lance (249 ± 18.6 ms) and WN+lance (253 ± 11.2 ms). This suggests that the click sound shortens the N2 latency of the ERP evoked by skin puncture. The ERP N2 latencies for SL, CL, ES, and IES were 146 ± 8.3, 149 ± 9.9, 148 ± 13.1, and 197 ± 21.2 ms, respectively. The ERP P2 latencies were 250 ± 18.2, 251 ± 14.1, 237 ± 26.3, and 294 ± 30.0 ms, respectively. The ERP latency for SL was significantly shorter than that for IES and was similar to that for ES. This suggests that the penetration force generated by the blade of the lance device activates the Aβ fibers, consequently shortening the ERP latency. Conclusions Lance ERP may reflect the activation of Aβ fibers rather than Aδ fibers. A pain index that correctly and reliably reflects nociceptive processing must be developed to improve pain assessment and management in neonates.
topic Skin puncture (lance)
Blood sampling
Pain
Nociceptive processing
Event-related potentials
Aβ fibers
url https://peerj.com/articles/12250.pdf
work_keys_str_mv AT yuishiroshita eventrelatedpotentialsevokedbyskinpuncturereflectactivationofabfiberscomparisonwithintraepidermalandtranscutaneouselectricalstimulations
AT hikarikirimoto eventrelatedpotentialsevokedbyskinpuncturereflectactivationofabfiberscomparisonwithintraepidermalandtranscutaneouselectricalstimulations
AT tatsunoriwatanabe eventrelatedpotentialsevokedbyskinpuncturereflectactivationofabfiberscomparisonwithintraepidermalandtranscutaneouselectricalstimulations
AT keisukeyunoki eventrelatedpotentialsevokedbyskinpuncturereflectactivationofabfiberscomparisonwithintraepidermalandtranscutaneouselectricalstimulations
AT ikukosobue eventrelatedpotentialsevokedbyskinpuncturereflectactivationofabfiberscomparisonwithintraepidermalandtranscutaneouselectricalstimulations
_version_ 1716829423003500544