Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa

Background: Optimum sputum results for acid-fast bacilli (AFB) microscopy are linked to a sputum quantity of at least 5.0 mL. This study was aimed at establishing the effect of sputum quantity in the pick-up rate of AFB microscopy by comparing sputum samples of 5.0 mL and 2.0 mL. Methods: An analyti...

Full description

Bibliographic Details
Main Authors: Iqbal Rashid, Langalibalele H. Mabuza, Indiran Govender, Deidre Pretorius
Format: Article
Language:English
Published: AOSIS 2011-10-01
Series:African Journal of Primary Health Care & Family Medicine
Subjects:
Online Access:https://phcfm.org/index.php/phcfm/article/view/240
id doaj-501413dde5a94e90bfbe5f2f45450009
record_format Article
spelling doaj-501413dde5a94e90bfbe5f2f454500092020-11-24T22:32:07ZengAOSISAfrican Journal of Primary Health Care & Family Medicine2071-29282071-29362011-10-0131e1e610.4102/phcfm.v3i1.240111Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South AfricaIqbal Rashid0Langalibalele H. Mabuza1Indiran Govender2Deidre Pretorius3Department of Family Medicine and Primary Health Care, University of Limpopo (Medunsa Campus)Department of Family Medicine and Primary Health Care, University of Limpopo (Medunsa Campus)Department of Family Medicine and Primary Health Care, University of Limpopo (Medunsa Campus)Department of Family Medicine and Primary Health Care, University of Limpopo (Medunsa Campus)Background: Optimum sputum results for acid-fast bacilli (AFB) microscopy are linked to a sputum quantity of at least 5.0 mL. This study was aimed at establishing the effect of sputum quantity in the pick-up rate of AFB microscopy by comparing sputum samples of 5.0 mL and 2.0 mL. Methods: An analytical cross-sectional study was carried out at the Dr George Mukhari Hospital (DGMH) in Pretoria, South Africa, from 05 January 2007 to 04 January 2008.Two sputum samples, 5.0 mL and 2.0 mL, were collected from each of the 330 adult PTB (pulmonary tuberculosis) suspects. Fluorescence microscopy was used in the sputum analysis. The yield through microscopy of the 2.0 mL specimen versus the 5.0 mL specimen was compared and analysed, using culture results as the gold standard. Results: From a sample of 330 specimens, 77 tested AFB positive on microscopy. In the 5.0 mL samples, the sensitivity was 76.6% (95% CI, 66.0% – 84.7%), specificity 99.6% (95% CI 97.8% – 99.9%), positive predictive value (PV+) 98.3% (95% CI 91.1% – 99.7%), negative predictive value (PV-) 93.3% (95% CI 89.7% – 95.7%), the likelihood ratio (LR) for a positive microscopy 192 and the LR for a negative test was 0.23. In the 2.0 mL specimens, the sensitivity was 75.3% (95% CI 64.6% – 83.6%), specificity 99.2% (95% CI 97.1% – 99.8%), positive predictive value (PV+) 96.7% (95% CI 88.6% – 99.1%), negative predictive value (PV-) 93.0% (95% CI 89.3% – 95.4%), the LR for a positive microscopy was 94 and 0.25 for a negative microscopy. There was a statistically significant association (p-value < 0.001) between the microscopy and culture tests in both the 5.0 mL and the 2.0 mL specimen categories. The strength of association between the microscopy and culture, as indicated by the kappa test was 0.83 and 0.81 in the 5.0 mL and 2.0 mL categories, respectively. Conclusion: Compared to the 2.0 mL specimen category, the yield for AFB microscopy in the 5.0 mL specimen category was consistently superior, as indicated by the higher sensitivity, specificity, predictive values and the likelihood ratios in the 5.0 mL specimen category. It is recommended that sputum specimen collection for AFB microscopy should aim for a minimum volume of 5.0 mL.https://phcfm.org/index.php/phcfm/article/view/240culturelikelihood ratiomicroscopysputum qualitysputum smear
collection DOAJ
language English
format Article
sources DOAJ
author Iqbal Rashid
Langalibalele H. Mabuza
Indiran Govender
Deidre Pretorius
spellingShingle Iqbal Rashid
Langalibalele H. Mabuza
Indiran Govender
Deidre Pretorius
Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa
African Journal of Primary Health Care & Family Medicine
culture
likelihood ratio
microscopy
sputum quality
sputum smear
author_facet Iqbal Rashid
Langalibalele H. Mabuza
Indiran Govender
Deidre Pretorius
author_sort Iqbal Rashid
title Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa
title_short Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa
title_full Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa
title_fullStr Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa
title_full_unstemmed Volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the Dr George Mukhari Hospital, South Africa
title_sort volume of sputum to detect acid-fast bacilli as a measure of quality for the diagnosis of pulmonary tuberculosis at the dr george mukhari hospital, south africa
publisher AOSIS
series African Journal of Primary Health Care & Family Medicine
issn 2071-2928
2071-2936
publishDate 2011-10-01
description Background: Optimum sputum results for acid-fast bacilli (AFB) microscopy are linked to a sputum quantity of at least 5.0 mL. This study was aimed at establishing the effect of sputum quantity in the pick-up rate of AFB microscopy by comparing sputum samples of 5.0 mL and 2.0 mL. Methods: An analytical cross-sectional study was carried out at the Dr George Mukhari Hospital (DGMH) in Pretoria, South Africa, from 05 January 2007 to 04 January 2008.Two sputum samples, 5.0 mL and 2.0 mL, were collected from each of the 330 adult PTB (pulmonary tuberculosis) suspects. Fluorescence microscopy was used in the sputum analysis. The yield through microscopy of the 2.0 mL specimen versus the 5.0 mL specimen was compared and analysed, using culture results as the gold standard. Results: From a sample of 330 specimens, 77 tested AFB positive on microscopy. In the 5.0 mL samples, the sensitivity was 76.6% (95% CI, 66.0% – 84.7%), specificity 99.6% (95% CI 97.8% – 99.9%), positive predictive value (PV+) 98.3% (95% CI 91.1% – 99.7%), negative predictive value (PV-) 93.3% (95% CI 89.7% – 95.7%), the likelihood ratio (LR) for a positive microscopy 192 and the LR for a negative test was 0.23. In the 2.0 mL specimens, the sensitivity was 75.3% (95% CI 64.6% – 83.6%), specificity 99.2% (95% CI 97.1% – 99.8%), positive predictive value (PV+) 96.7% (95% CI 88.6% – 99.1%), negative predictive value (PV-) 93.0% (95% CI 89.3% – 95.4%), the LR for a positive microscopy was 94 and 0.25 for a negative microscopy. There was a statistically significant association (p-value < 0.001) between the microscopy and culture tests in both the 5.0 mL and the 2.0 mL specimen categories. The strength of association between the microscopy and culture, as indicated by the kappa test was 0.83 and 0.81 in the 5.0 mL and 2.0 mL categories, respectively. Conclusion: Compared to the 2.0 mL specimen category, the yield for AFB microscopy in the 5.0 mL specimen category was consistently superior, as indicated by the higher sensitivity, specificity, predictive values and the likelihood ratios in the 5.0 mL specimen category. It is recommended that sputum specimen collection for AFB microscopy should aim for a minimum volume of 5.0 mL.
topic culture
likelihood ratio
microscopy
sputum quality
sputum smear
url https://phcfm.org/index.php/phcfm/article/view/240
work_keys_str_mv AT iqbalrashid volumeofsputumtodetectacidfastbacilliasameasureofqualityforthediagnosisofpulmonarytuberculosisatthedrgeorgemukharihospitalsouthafrica
AT langalibalelehmabuza volumeofsputumtodetectacidfastbacilliasameasureofqualityforthediagnosisofpulmonarytuberculosisatthedrgeorgemukharihospitalsouthafrica
AT indirangovender volumeofsputumtodetectacidfastbacilliasameasureofqualityforthediagnosisofpulmonarytuberculosisatthedrgeorgemukharihospitalsouthafrica
AT deidrepretorius volumeofsputumtodetectacidfastbacilliasameasureofqualityforthediagnosisofpulmonarytuberculosisatthedrgeorgemukharihospitalsouthafrica
_version_ 1725735076223778816