Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces
Due to disadvantages of seismic behavior in conventional braces in term of low plasticity and asymmetric hysteresis curve in tension and compression and pinching which reduces the energy dissipation rate, Buckling Restrained Braces (BRBs) have been proposed as a new generation of bracing system. Thi...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Iranian Society of Structrual Engineering (ISSE)
2017-05-01
|
Series: | Journal of Structural and Construction Engineering |
Subjects: | |
Online Access: | http://www.jsce.ir/article_43234_e1f4a8a0b4f00b9d84ac77272ec85ca6.pdf |
id |
doaj-4f99b3956aa14d39865bb1e449a3625b |
---|---|
record_format |
Article |
spelling |
doaj-4f99b3956aa14d39865bb1e449a3625b2020-11-24T20:54:17ZfasIranian Society of Structrual Engineering (ISSE)Journal of Structural and Construction Engineering2476-39772538-26162017-05-0141516210.22065/jsce.2017.4323443234Investigate effects of the core distance from confining concrete on behavior of buckling restrained bracesMadjid Gholhaki0Amin Jamali Far1Omid Rezaei Far2Associate Professor, Department of Civil Engineering, University of Semnan, Semnan, IranMSc of Structural Engineering, Department of Civil Engineering, University of Semnan, Semnan, IranAssistant Professor, Civil Engineering Department, University of Semnan, Semnan, IranDue to disadvantages of seismic behavior in conventional braces in term of low plasticity and asymmetric hysteresis curve in tension and compression and pinching which reduces the energy dissipation rate, Buckling Restrained Braces (BRBs) have been proposed as a new generation of bracing system. This paper examines specific type of these braces with steel core and concrete sheath. The effects of core distancefrom confining concrete of these braces haven been discussed using Finite element analysis method. The results show that buckling mode and energy absorption of this system have largely depend on the distance, and 2 to 4 mm distance causes the most energy dissipation.http://www.jsce.ir/article_43234_e1f4a8a0b4f00b9d84ac77272ec85ca6.pdfBuckling Restrained Brace (BRB)core distance from concretehysteresis curveEnergy dissipation |
collection |
DOAJ |
language |
fas |
format |
Article |
sources |
DOAJ |
author |
Madjid Gholhaki Amin Jamali Far Omid Rezaei Far |
spellingShingle |
Madjid Gholhaki Amin Jamali Far Omid Rezaei Far Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces Journal of Structural and Construction Engineering Buckling Restrained Brace (BRB) core distance from concrete hysteresis curve Energy dissipation |
author_facet |
Madjid Gholhaki Amin Jamali Far Omid Rezaei Far |
author_sort |
Madjid Gholhaki |
title |
Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces |
title_short |
Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces |
title_full |
Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces |
title_fullStr |
Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces |
title_full_unstemmed |
Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces |
title_sort |
investigate effects of the core distance from confining concrete on behavior of buckling restrained braces |
publisher |
Iranian Society of Structrual Engineering (ISSE) |
series |
Journal of Structural and Construction Engineering |
issn |
2476-3977 2538-2616 |
publishDate |
2017-05-01 |
description |
Due to disadvantages of seismic behavior in conventional braces in term of low plasticity and asymmetric hysteresis curve in tension and compression and pinching which reduces the energy dissipation rate, Buckling Restrained Braces (BRBs) have been proposed as a new generation of bracing system. This paper examines specific type of these braces with steel core and concrete sheath. The effects of core distancefrom confining concrete of these braces haven been discussed using Finite element analysis method. The results show that buckling mode and energy absorption of this system have largely depend on the distance, and 2 to 4 mm distance causes the most energy dissipation. |
topic |
Buckling Restrained Brace (BRB) core distance from concrete hysteresis curve Energy dissipation |
url |
http://www.jsce.ir/article_43234_e1f4a8a0b4f00b9d84ac77272ec85ca6.pdf |
work_keys_str_mv |
AT madjidgholhaki investigateeffectsofthecoredistancefromconfiningconcreteonbehaviorofbucklingrestrainedbraces AT aminjamalifar investigateeffectsofthecoredistancefromconfiningconcreteonbehaviorofbucklingrestrainedbraces AT omidrezaeifar investigateeffectsofthecoredistancefromconfiningconcreteonbehaviorofbucklingrestrainedbraces |
_version_ |
1716795049708093440 |