Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination

In this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was vali...

Full description

Bibliographic Details
Main Authors: Matjaž Finšgar, David Majer, Uroš Maver, Tina Maver
Format: Article
Language:English
Published: MDPI AG 2018-11-01
Series:Sensors
Subjects:
SPE
EIS
Online Access:https://www.mdpi.com/1424-8220/18/11/3976
id doaj-4f7031b67c6e46a3a6c515e38349538b
record_format Article
spelling doaj-4f7031b67c6e46a3a6c515e38349538b2020-11-24T23:03:20ZengMDPI AGSensors1424-82202018-11-011811397610.3390/s18113976s18113976Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) DeterminationMatjaž Finšgar0David Majer1Uroš Maver2Tina Maver3Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, SloveniaFaculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, SloveniaFaculty of Medicine, Institute of Biomedical Sciences, University of Maribor, Taborska ulica 8, SI-2000 Maribor, SloveniaFaculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, SloveniaIn this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was validated for an accumulation potential of &#8315;1.1 V vs. Ag/AgCl and an accumulation time of 60 s. A comparative analysis of bare SPE and SbFSPE showed that the detection and quantification limits decrease for the bare SPE. The method with the bare SPE showed a linear response in the 69.8&#8315;368.4 &#181;g/L concentration range, whereas linearity for the SbFSPE was in the 24.0&#8315;319.1 &#181;g/L concentration range. This work also reports the reason why the multiple standard addition method instead of a linear calibration curve for Pb(II) analysis should be employed. Furthermore, the analytical method employing SbFSPE was found to be more accurate and precise compared to the use of bare SPE when sensors were employed for the first time, however this performance changed significantly when these sensors were reused in the same manner. Furthermore, electrochemical impedance spectroscopy was used for the first time to analyse the electrochemical response of sensors after being used for multiple successive analyses. Surface characterisation before and after multiple successive uses of bare SPE and SbFSPE sensors, with atomic force microscopy and field emission scanning electron microscopy, showed sensor degradation. The interference effect of Cd(II), Zn(II), As(III), Fe(II), Na(I), K(I), Ca(II), Mg(II), NO<sub>3</sub><sup>&#8315;</sup>, Bi(III), Cu(II), Sn(II), and Hg(II) on the Pb(II) stripping signal was also studied. Finally, the application of SbFSPE was tested on a real water sample (from a local river), which showed high precision (RSD = 8.1%, <i>n</i> = 5) and accurate results.https://www.mdpi.com/1424-8220/18/11/3976screen-printed electrodeSb-film electrodeSPESbFEstripping analysisEIS
collection DOAJ
language English
format Article
sources DOAJ
author Matjaž Finšgar
David Majer
Uroš Maver
Tina Maver
spellingShingle Matjaž Finšgar
David Majer
Uroš Maver
Tina Maver
Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
Sensors
screen-printed electrode
Sb-film electrode
SPE
SbFE
stripping analysis
EIS
author_facet Matjaž Finšgar
David Majer
Uroš Maver
Tina Maver
author_sort Matjaž Finšgar
title Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_short Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_full Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_fullStr Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_full_unstemmed Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination
title_sort reusability of spe and sb-modified spe sensors for trace pb(ii) determination
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2018-11-01
description In this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was validated for an accumulation potential of &#8315;1.1 V vs. Ag/AgCl and an accumulation time of 60 s. A comparative analysis of bare SPE and SbFSPE showed that the detection and quantification limits decrease for the bare SPE. The method with the bare SPE showed a linear response in the 69.8&#8315;368.4 &#181;g/L concentration range, whereas linearity for the SbFSPE was in the 24.0&#8315;319.1 &#181;g/L concentration range. This work also reports the reason why the multiple standard addition method instead of a linear calibration curve for Pb(II) analysis should be employed. Furthermore, the analytical method employing SbFSPE was found to be more accurate and precise compared to the use of bare SPE when sensors were employed for the first time, however this performance changed significantly when these sensors were reused in the same manner. Furthermore, electrochemical impedance spectroscopy was used for the first time to analyse the electrochemical response of sensors after being used for multiple successive analyses. Surface characterisation before and after multiple successive uses of bare SPE and SbFSPE sensors, with atomic force microscopy and field emission scanning electron microscopy, showed sensor degradation. The interference effect of Cd(II), Zn(II), As(III), Fe(II), Na(I), K(I), Ca(II), Mg(II), NO<sub>3</sub><sup>&#8315;</sup>, Bi(III), Cu(II), Sn(II), and Hg(II) on the Pb(II) stripping signal was also studied. Finally, the application of SbFSPE was tested on a real water sample (from a local river), which showed high precision (RSD = 8.1%, <i>n</i> = 5) and accurate results.
topic screen-printed electrode
Sb-film electrode
SPE
SbFE
stripping analysis
EIS
url https://www.mdpi.com/1424-8220/18/11/3976
work_keys_str_mv AT matjazfinsgar reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
AT davidmajer reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
AT urosmaver reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
AT tinamaver reusabilityofspeandsbmodifiedspesensorsfortracepbiidetermination
_version_ 1725634364158509056