PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS
This study aims to generate power supply precision instrument digital display a valid and practical for students of physics 3rd semester of the school year 2014/2015. This research includes development research (research development) of the power supply circuit that has been common there are some dr...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
Institut Agama Islam Negeri (IAIN) Batusangkar
2017-03-01
|
Series: | Sainstek: Jurnal Sains dan Teknologi |
Subjects: | |
Online Access: | http://ecampus.iainbatusangkar.ac.id/ojs/index.php/sainstek/article/view/482 |
id |
doaj-4ecf29f51a7e449289fdca5a4fe42917 |
---|---|
record_format |
Article |
spelling |
doaj-4ecf29f51a7e449289fdca5a4fe429172020-11-25T00:50:54ZindInstitut Agama Islam Negeri (IAIN) BatusangkarSainstek: Jurnal Sains dan Teknologi2085-80192580-278X2017-03-0182193202461PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMISBushra Hamid0Frans Rizal Agustiyanto1Yulkifli Yulkifli2Jurusan Fisika Fakultas Tarbiyah dan Ilmu Keguruan IAIN Batusangkar Jalan Sudirman No. 137 Kubu Rajo, Lima Kaum Batusangkar 27213.Jurusan Fisika Fakultas Tarbiyah dan Ilmu Keguruan IAIN Batusangkar Jalan Sudirman No. 137 Kubu Rajo, Lima Kaum Batusangkar 27213.Jurusan Fisika FMIPA Universitas Negeri PadangThis study aims to generate power supply precision instrument digital display a valid and practical for students of physics 3rd semester of the school year 2014/2015. This research includes development research (research development) of the power supply circuit that has been common there are some drawbacks, namely, the output of output that does not fit, there is still AC voltage on the output value, the output voltage is unstable, so that the results of the lab basic physics 2 be not in accordance with the results of the theory. The addition of the diode bridge circuit helps perfect output voltage into DC, the capacitors in the circuit capacity was raised as a reliever ripple or ripples form to obtain a stable DC voltage value, for a voltage stabilizer is also used IC9815 surge protector. Limited trial conducted in STAIN Batusangakar to 26 students. Based on the results of data analysis has been carried out can be summarized as follows: (1) The results of the validation tool precision power supply digital display is very valid. (2) The results of trials carried out showed that the practicalities have met the criteria that can be used and implemented in a lab with practicality very practical value.http://ecampus.iainbatusangkar.ac.id/ojs/index.php/sainstek/article/view/482research and development, power supply, display digital |
collection |
DOAJ |
language |
Indonesian |
format |
Article |
sources |
DOAJ |
author |
Bushra Hamid Frans Rizal Agustiyanto Yulkifli Yulkifli |
spellingShingle |
Bushra Hamid Frans Rizal Agustiyanto Yulkifli Yulkifli PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS Sainstek: Jurnal Sains dan Teknologi research and development, power supply, display digital |
author_facet |
Bushra Hamid Frans Rizal Agustiyanto Yulkifli Yulkifli |
author_sort |
Bushra Hamid |
title |
PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS |
title_short |
PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS |
title_full |
PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS |
title_fullStr |
PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS |
title_full_unstemmed |
PENGEMBANGAN CATU DAYA PRESISI DISPLAY DIGITAL UNTUK PRAKTIKUM FISIKA LISTRIK DINAMIS |
title_sort |
pengembangan catu daya presisi display digital untuk praktikum fisika listrik dinamis |
publisher |
Institut Agama Islam Negeri (IAIN) Batusangkar |
series |
Sainstek: Jurnal Sains dan Teknologi |
issn |
2085-8019 2580-278X |
publishDate |
2017-03-01 |
description |
This study aims to generate power supply precision instrument digital display a valid and practical for students of physics 3rd semester of the school year 2014/2015. This research includes development research (research development) of the power supply circuit that has been common there are some drawbacks, namely, the output of output that does not fit, there is still AC voltage on the output value, the output voltage is unstable, so that the results of the lab basic physics 2 be not in accordance with the results of the theory. The addition of the diode bridge circuit helps perfect output voltage into DC, the capacitors in the circuit capacity was raised as a reliever ripple or ripples form to obtain a stable DC voltage value, for a voltage stabilizer is also used IC9815 surge protector. Limited trial conducted in STAIN Batusangakar to 26 students. Based on the results of data analysis has been carried out can be summarized as follows: (1) The results of the validation tool precision power supply digital display is very valid. (2) The results of trials carried out showed that the practicalities have met the criteria that can be used and implemented in a lab with practicality very practical value. |
topic |
research and development, power supply, display digital |
url |
http://ecampus.iainbatusangkar.ac.id/ojs/index.php/sainstek/article/view/482 |
work_keys_str_mv |
AT bushrahamid pengembangancatudayapresisidisplaydigitaluntukpraktikumfisikalistrikdinamis AT fransrizalagustiyanto pengembangancatudayapresisidisplaydigitaluntukpraktikumfisikalistrikdinamis AT yulkifliyulkifli pengembangancatudayapresisidisplaydigitaluntukpraktikumfisikalistrikdinamis |
_version_ |
1725245988907515904 |