Executive Disadvantages in the Layered Wall of the Facade

In this paper a case of three-layer wall and fitting windows is described. The walls outside layer are made of clinker brick. The public basis is a situation, which occurred in an office building. In this building was a water stain on the windows inside the upstairs part the building, during the rai...

Full description

Bibliographic Details
Main Authors: Grochowska Elżbieta, Matysiak Antoni
Format: Article
Language:English
Published: Sciendo 2016-09-01
Series:Civil and Environmental Engineering Reports
Subjects:
Online Access:http://www.degruyter.com/view/j/ceer.2016.22.issue-3/ceer-2016-0034/ceer-2016-0034.xml?format=INT
id doaj-4d7a025bde424c62a4166cf61bd29d12
record_format Article
spelling doaj-4d7a025bde424c62a4166cf61bd29d122020-11-25T01:03:31ZengSciendoCivil and Environmental Engineering Reports2450-85942016-09-01223556010.1515/ceer-2016-0034ceer-2016-0034Executive Disadvantages in the Layered Wall of the FacadeGrochowska Elżbieta0Matysiak Antoni1University of Zielona Gora, Faculty of Building, Architecture and Environmental Engineering, Z. Szafrana st 1, 65-516 Zielona Góra, tel.+48683282320, PolandUniversity of Zielona Gora, Faculty of Building, Architecture and Environmental Engineering, Z. Szafrana st 1, 65-516 Zielona Góra, tel.+48683283282251, PolandIn this paper a case of three-layer wall and fitting windows is described. The walls outside layer are made of clinker brick. The public basis is a situation, which occurred in an office building. In this building was a water stain on the windows inside the upstairs part the building, during the rain. In project of the building there were no details of performing three-layer wall and fitting of windows. In Poland one did not described in detail the realization for windows installation in three-layer wall.http://www.degruyter.com/view/j/ceer.2016.22.issue-3/ceer-2016-0034/ceer-2016-0034.xml?format=INThree-layer wallfit windowsdefect regulationsbuilding project
collection DOAJ
language English
format Article
sources DOAJ
author Grochowska Elżbieta
Matysiak Antoni
spellingShingle Grochowska Elżbieta
Matysiak Antoni
Executive Disadvantages in the Layered Wall of the Facade
Civil and Environmental Engineering Reports
hree-layer wall
fit windows
defect regulations
building project
author_facet Grochowska Elżbieta
Matysiak Antoni
author_sort Grochowska Elżbieta
title Executive Disadvantages in the Layered Wall of the Facade
title_short Executive Disadvantages in the Layered Wall of the Facade
title_full Executive Disadvantages in the Layered Wall of the Facade
title_fullStr Executive Disadvantages in the Layered Wall of the Facade
title_full_unstemmed Executive Disadvantages in the Layered Wall of the Facade
title_sort executive disadvantages in the layered wall of the facade
publisher Sciendo
series Civil and Environmental Engineering Reports
issn 2450-8594
publishDate 2016-09-01
description In this paper a case of three-layer wall and fitting windows is described. The walls outside layer are made of clinker brick. The public basis is a situation, which occurred in an office building. In this building was a water stain on the windows inside the upstairs part the building, during the rain. In project of the building there were no details of performing three-layer wall and fitting of windows. In Poland one did not described in detail the realization for windows installation in three-layer wall.
topic hree-layer wall
fit windows
defect regulations
building project
url http://www.degruyter.com/view/j/ceer.2016.22.issue-3/ceer-2016-0034/ceer-2016-0034.xml?format=INT
work_keys_str_mv AT grochowskaelzbieta executivedisadvantagesinthelayeredwallofthefacade
AT matysiakantoni executivedisadvantagesinthelayeredwallofthefacade
_version_ 1725200874248077312