Force-touch measurement methodology based on user experience

The touch interface is an input method widely used in smart devices. Recently, new touch interface which supports force value has been introduced. The force-touch interface adds a factor called depth to the plane coordinates as compared to the existing touch interface. Despite the advantages of forc...

Full description

Bibliographic Details
Main Authors: Choonsung Nam, DongRyeol Shin
Format: Article
Language:English
Published: SAGE Publishing 2018-04-01
Series:International Journal of Distributed Sensor Networks
Online Access:https://doi.org/10.1177/1550147718767794
id doaj-4d4b47a4a3254d47921da0d07de257f9
record_format Article
spelling doaj-4d4b47a4a3254d47921da0d07de257f92020-11-25T03:49:53ZengSAGE PublishingInternational Journal of Distributed Sensor Networks1550-14772018-04-011410.1177/1550147718767794Force-touch measurement methodology based on user experienceChoonsung NamDongRyeol ShinThe touch interface is an input method widely used in smart devices. Recently, new touch interface which supports force value has been introduced. The force-touch interface adds a factor called depth to the plane coordinates as compared to the existing touch interface. Despite the advantages of force-touch, which can provide touch position and force intensity information with one input, there are still many devices that cannot support force values. To provide them with a force-touch interface, we developed a force-touch cover for existing smart devices that do not support the existing force value. It is a way to provide the force value to the smart device by recognizing the force value through the sensor installed in smartphone case. However, it is difficult to apply the force value obtained through such a device directly to the force-touch interface, because it is necessary to distinguish between force touch and general touch. Therefore, in order to use the force-touch interface using the force-touch cover proposed in this article, the force value measured at the time of general touch is analyzed by user experiment to set the general touch area. Also, an area outside the general touch area is set as the force-touch area. In the force-touch and general touch area, the area is applied considering the error of the force value actually measured in the developed force-touch cover. Therefore, in this article, we analyze the force value input through the proposed force-touch cover and find a reference value that can distinguish force touch from general touch by user experiment and propose a method to apply it.https://doi.org/10.1177/1550147718767794
collection DOAJ
language English
format Article
sources DOAJ
author Choonsung Nam
DongRyeol Shin
spellingShingle Choonsung Nam
DongRyeol Shin
Force-touch measurement methodology based on user experience
International Journal of Distributed Sensor Networks
author_facet Choonsung Nam
DongRyeol Shin
author_sort Choonsung Nam
title Force-touch measurement methodology based on user experience
title_short Force-touch measurement methodology based on user experience
title_full Force-touch measurement methodology based on user experience
title_fullStr Force-touch measurement methodology based on user experience
title_full_unstemmed Force-touch measurement methodology based on user experience
title_sort force-touch measurement methodology based on user experience
publisher SAGE Publishing
series International Journal of Distributed Sensor Networks
issn 1550-1477
publishDate 2018-04-01
description The touch interface is an input method widely used in smart devices. Recently, new touch interface which supports force value has been introduced. The force-touch interface adds a factor called depth to the plane coordinates as compared to the existing touch interface. Despite the advantages of force-touch, which can provide touch position and force intensity information with one input, there are still many devices that cannot support force values. To provide them with a force-touch interface, we developed a force-touch cover for existing smart devices that do not support the existing force value. It is a way to provide the force value to the smart device by recognizing the force value through the sensor installed in smartphone case. However, it is difficult to apply the force value obtained through such a device directly to the force-touch interface, because it is necessary to distinguish between force touch and general touch. Therefore, in order to use the force-touch interface using the force-touch cover proposed in this article, the force value measured at the time of general touch is analyzed by user experiment to set the general touch area. Also, an area outside the general touch area is set as the force-touch area. In the force-touch and general touch area, the area is applied considering the error of the force value actually measured in the developed force-touch cover. Therefore, in this article, we analyze the force value input through the proposed force-touch cover and find a reference value that can distinguish force touch from general touch by user experiment and propose a method to apply it.
url https://doi.org/10.1177/1550147718767794
work_keys_str_mv AT choonsungnam forcetouchmeasurementmethodologybasedonuserexperience
AT dongryeolshin forcetouchmeasurementmethodologybasedonuserexperience
_version_ 1724493569663696896