Rapid Fault Diagnosis of PEM Fuel Cells through Optimal Electrochemical Impedance Spectroscopy Tests

The present paper is focused on proposing and implementing a methodology for robust and rapid diagnosis of PEM fuel cells’ faults using Electrochemical Impedance Spectroscopy (EIS). Accordingly, EIS tests have been first conducted on four identical fresh PEM fuel cells along with an aged PEMFC at di...

Full description

Bibliographic Details
Main Authors: Behzad Najafi, Paolo Bonomi, Andrea Casalegno, Fabio Rinaldi, Andrea Baricci
Format: Article
Language:English
Published: MDPI AG 2020-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/14/3643
Description
Summary:The present paper is focused on proposing and implementing a methodology for robust and rapid diagnosis of PEM fuel cells’ faults using Electrochemical Impedance Spectroscopy (EIS). Accordingly, EIS tests have been first conducted on four identical fresh PEM fuel cells along with an aged PEMFC at different current density levels and operating conditions. A label, which represents the presence of a type of fault (flooding or dehydration) or the regular operation, is then assigned to each test based on the expert knowledge employing the cell’s spectrum on the Nyquist plot. Since the time required to generate the spectrum should be minimized and considering the notable difference in the time needed for carrying out EIS tests at different frequency ranges, the frequencies have been categorized into four clusters (based on the corresponding order of magnitude: >1 kHz, >100 Hz, >10 Hz, >1 Hz). Next, for each frequency cluster and each specific current density, while utilizing a classification algorithm, a feature selection procedure is implemented in order to find the combination of EIS frequencies utilizing which results in the highest fault diagnosis accuracy and requires the lowest EIS testing time. For the case of fresh cells, employing the cluster of frequencies with <inline-formula> <math display="inline"> <semantics> <mrow> <mi>f</mi> <mo>></mo> <mn>10</mn> </mrow> </semantics> </math> </inline-formula> Hz, an accuracy of <inline-formula> <math display="inline"> <semantics> <mrow> <mn>98.5</mn> <mo>%</mo> </mrow> </semantics> </math> </inline-formula> is obtained, whereas once the EIS tests from degraded cells are added to the dataset, the achieved accuracy is reduced to <inline-formula> <math display="inline"> <semantics> <mrow> <mn>89.2</mn> <mo>%</mo> </mrow> </semantics> </math> </inline-formula>. It is also demonstrated that, while utilizing the selected pipelines, the required time for conducting the EIS test is less than one second, an advantage that facilitates real-time in-operando diagnosis of water management issues.
ISSN:1996-1073