Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiolog...

Full description

Bibliographic Details
Main Authors: Hassan Zarghani, Mohammadtaghi bahreyni
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2018-01-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:http://ijmp.mums.ac.ir/article_9316_2eb3abc6f480eef6fda08852135a3beb.pdf
id doaj-4cd139b5a55649a8a53db5f4684a3b09
record_format Article
spelling doaj-4cd139b5a55649a8a53db5f4684a3b092020-11-24T22:30:41ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722018-01-01151626510.22038/ijmp.2017.19211.12379316Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of IranHassan Zarghani0Mohammadtaghi bahreyni1Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, IranMedical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, IranIntroduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments in Sabzevar County, Iran. The entrance skin dose (ESD) distributions were determined by use of thermoluminescence dosimeter (TLD) chips for 10 standard projections (i.e., anterioposterior [AP] abdomen, AP and posteroanterior [PA] chest, AP and lateral [LAT] lumbar spine, AP pelvis, cervical AP, cervical LAT, as well as AP and LAT skull). The third quartiles of the measured ESDs were compared with the previously published data. Results: In the present study, the third quartile of the measured ESDs for the patients undergoing specific examination were selected as LDRLs. The calculated LDRLs for the chest PA, chest AP, lumbar spine PA, lumbar spine LAT, pelvis AP, abdomen AP, cervical AP, cervical LAT, skull PA, and skull LAT were 0.54, 0.64, 1.99, 3.83, 1.47, 2.15, 0.54, 0.78, 1.22, and 1.01 mGy, respectively. Conclusion: Our results were compared with the DRLs reported in Iran, UK, and Japan as well as those reported by the National Radiological Protection Board (NPRB) for the UK. The ESDs obtained in this study for the chest PA, cervical AP, cervical LAT, AP and LAT skull, abdomen AP, pelvis AP, lumbar PA, and lumbar LAT examinations did not exceed the DRL values reported by NPRB.http://ijmp.mums.ac.ir/article_9316_2eb3abc6f480eef6fda08852135a3beb.pdfDiagnostic X-RayRadiographyRadiation Dosageradiation protection
collection DOAJ
language English
format Article
sources DOAJ
author Hassan Zarghani
Mohammadtaghi bahreyni
spellingShingle Hassan Zarghani
Mohammadtaghi bahreyni
Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
Iranian Journal of Medical Physics
Diagnostic X-Ray
Radiography
Radiation Dosage
radiation protection
author_facet Hassan Zarghani
Mohammadtaghi bahreyni
author_sort Hassan Zarghani
title Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
title_short Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
title_full Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
title_fullStr Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
title_full_unstemmed Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
title_sort local diagnostic reference levels for some common diagnostic x-ray examinations in sabzevar county of iran
publisher Mashhad University of Medical Sciences
series Iranian Journal of Medical Physics
issn 2345-3672
2345-3672
publishDate 2018-01-01
description Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments in Sabzevar County, Iran. The entrance skin dose (ESD) distributions were determined by use of thermoluminescence dosimeter (TLD) chips for 10 standard projections (i.e., anterioposterior [AP] abdomen, AP and posteroanterior [PA] chest, AP and lateral [LAT] lumbar spine, AP pelvis, cervical AP, cervical LAT, as well as AP and LAT skull). The third quartiles of the measured ESDs were compared with the previously published data. Results: In the present study, the third quartile of the measured ESDs for the patients undergoing specific examination were selected as LDRLs. The calculated LDRLs for the chest PA, chest AP, lumbar spine PA, lumbar spine LAT, pelvis AP, abdomen AP, cervical AP, cervical LAT, skull PA, and skull LAT were 0.54, 0.64, 1.99, 3.83, 1.47, 2.15, 0.54, 0.78, 1.22, and 1.01 mGy, respectively. Conclusion: Our results were compared with the DRLs reported in Iran, UK, and Japan as well as those reported by the National Radiological Protection Board (NPRB) for the UK. The ESDs obtained in this study for the chest PA, cervical AP, cervical LAT, AP and LAT skull, abdomen AP, pelvis AP, lumbar PA, and lumbar LAT examinations did not exceed the DRL values reported by NPRB.
topic Diagnostic X-Ray
Radiography
Radiation Dosage
radiation protection
url http://ijmp.mums.ac.ir/article_9316_2eb3abc6f480eef6fda08852135a3beb.pdf
work_keys_str_mv AT hassanzarghani localdiagnosticreferencelevelsforsomecommondiagnosticxrayexaminationsinsabzevarcountyofiran
AT mohammadtaghibahreyni localdiagnosticreferencelevelsforsomecommondiagnosticxrayexaminationsinsabzevarcountyofiran
_version_ 1725739845195661312