Possibilities of diagnosing the condition of contact wire in terms of thermal wear

The paper considers the negative consequences of thermal softening of the contact wire material under the action of an electric arc, which is thermal wear. In order to determine the degree of softening of the contact wire in real time, the methodology for assessing the condition of the contact wire...

Full description

Bibliographic Details
Main Authors: Klimenko Sergey, Li Vladimir
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201823901050
id doaj-4b6c32b5933f491c91936c90aedca94c
record_format Article
spelling doaj-4b6c32b5933f491c91936c90aedca94c2021-02-02T07:54:13ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-012390105010.1051/matecconf/201823901050matecconf_ts2018_01050Possibilities of diagnosing the condition of contact wire in terms of thermal wearKlimenko Sergey0Li Vladimir1Far Eastern State Transport UniversityFar Eastern State Transport UniversityThe paper considers the negative consequences of thermal softening of the contact wire material under the action of an electric arc, which is thermal wear. In order to determine the degree of softening of the contact wire in real time, the methodology for assessing the condition of the contact wire of electrified railways by the value of thermal wear is presented. The presented method is based on the criterial approach. The criteria for softening the material of the wire and the transition of the material to the liquid state are introduced. By comparing the amount of heat entering the wire in the event of an electric arc (with these criteria), the contact wire is diagnosed in terms of thermal wear. Calculations have been made using the proposed method; graphical dependences of the amount of heat entering the wire element on the current intensity of the electric arc for various times of its influence on the contact wire are constructed. A device for diagnosing the condition of the contact wire in terms of the amount of thermal wear is proposed, designed to record the place of occurrence of the electric arc, to collect and transmit the necessary initial data. The operating principle of the device is described and its structural diagram is given. The use of the method for assessing the condition of the contact wire in terms of the amount of thermal wear and the diagnostic device will make it possible to quantify the degree of thermal softening of the contact wire material in order to further determine its residual life.https://doi.org/10.1051/matecconf/201823901050
collection DOAJ
language English
format Article
sources DOAJ
author Klimenko Sergey
Li Vladimir
spellingShingle Klimenko Sergey
Li Vladimir
Possibilities of diagnosing the condition of contact wire in terms of thermal wear
MATEC Web of Conferences
author_facet Klimenko Sergey
Li Vladimir
author_sort Klimenko Sergey
title Possibilities of diagnosing the condition of contact wire in terms of thermal wear
title_short Possibilities of diagnosing the condition of contact wire in terms of thermal wear
title_full Possibilities of diagnosing the condition of contact wire in terms of thermal wear
title_fullStr Possibilities of diagnosing the condition of contact wire in terms of thermal wear
title_full_unstemmed Possibilities of diagnosing the condition of contact wire in terms of thermal wear
title_sort possibilities of diagnosing the condition of contact wire in terms of thermal wear
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2018-01-01
description The paper considers the negative consequences of thermal softening of the contact wire material under the action of an electric arc, which is thermal wear. In order to determine the degree of softening of the contact wire in real time, the methodology for assessing the condition of the contact wire of electrified railways by the value of thermal wear is presented. The presented method is based on the criterial approach. The criteria for softening the material of the wire and the transition of the material to the liquid state are introduced. By comparing the amount of heat entering the wire in the event of an electric arc (with these criteria), the contact wire is diagnosed in terms of thermal wear. Calculations have been made using the proposed method; graphical dependences of the amount of heat entering the wire element on the current intensity of the electric arc for various times of its influence on the contact wire are constructed. A device for diagnosing the condition of the contact wire in terms of the amount of thermal wear is proposed, designed to record the place of occurrence of the electric arc, to collect and transmit the necessary initial data. The operating principle of the device is described and its structural diagram is given. The use of the method for assessing the condition of the contact wire in terms of the amount of thermal wear and the diagnostic device will make it possible to quantify the degree of thermal softening of the contact wire material in order to further determine its residual life.
url https://doi.org/10.1051/matecconf/201823901050
work_keys_str_mv AT klimenkosergey possibilitiesofdiagnosingtheconditionofcontactwireintermsofthermalwear
AT livladimir possibilitiesofdiagnosingtheconditionofcontactwireintermsofthermalwear
_version_ 1724298280324562944