Late Thrombosis of Sirolimus-Eluting Stent: A Multifactorial Problem
We report a case of a young patient in whom a sirolimus-eluting stent was implanted on the culprit left anterior descending coronary artery at primary percutaneous coronary intervention (PCI) for acute myocardial infarction. Nine months later she suffered from a reinfarction due to the late stent th...
Main Authors: | Igor Kranjec, Andreja Cerne |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2009-01-01
|
Series: | Case Reports in Medicine |
Online Access: | http://dx.doi.org/10.1155/2009/816715 |
Similar Items
-
Very Late Stent Thrombosis 42 Months after Implantation of Sirolimus-Eluting Stent and Discontinuation of Antiplatelet Therapy
by: Dirk Sibbing, et al.
Published: (2009-01-01) -
Sirolimus-eluting coronary stents: a review
by: Alexandre Abizaid
Published: (2007-05-01) -
A meta-analysis of everolimus-eluting stents versus sirolimus-eluting stents and paclitaxel-eluting stents in diabetic patients
by: Hang Ouyang, et al.
Published: (2021-04-01) -
Long-Term Clinical Outcome after Sirolimus-Stent Implantation for in Sirolimus-Eluting Stent Restenosis
by: Alain Guidon, et al.
Published: (2008-01-01) -
Very late stent thrombosis of Sirolimus-eluting stent 59 months after implantation: A first report from the Middle-East and review of literature
by: Prashanth Panduranga, et al.
Published: (2011-01-01)