Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends

The time domain response of uniform RC lines with resistive termination at both ends is obtained by obtaining the approximate poles of the transfer function. A simple model is developed for the URC line. The model consists of three passive elements only and can be easily implemented for computeraide...

Full description

Bibliographic Details
Main Author: Muhammad Taher Abuelma'atti
Format: Article
Language:English
Published: Hindawi Limited 1994-01-01
Series:Active and Passive Electronic Components
Online Access:http://dx.doi.org/10.1155/1994/63861
id doaj-4aeda2d6300a4c8ebb593fe8cd301c4d
record_format Article
spelling doaj-4aeda2d6300a4c8ebb593fe8cd301c4d2020-11-24T22:47:24ZengHindawi LimitedActive and Passive Electronic Components0882-75161563-50311994-01-01163-413514010.1155/1994/63861Time Domain Response of Uniform RC Lines With Resistive Termination at Both EndsMuhammad Taher Abuelma'atti0Kung Fahd University of Petroleum and Minerals, Box 203, Dhahran 31261, Saudi ArabiaThe time domain response of uniform RC lines with resistive termination at both ends is obtained by obtaining the approximate poles of the transfer function. A simple model is developed for the URC line. The model consists of three passive elements only and can be easily implemented for computeraided analysis of URC lines with resistive termination at both ends.http://dx.doi.org/10.1155/1994/63861
collection DOAJ
language English
format Article
sources DOAJ
author Muhammad Taher Abuelma'atti
spellingShingle Muhammad Taher Abuelma'atti
Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends
Active and Passive Electronic Components
author_facet Muhammad Taher Abuelma'atti
author_sort Muhammad Taher Abuelma'atti
title Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends
title_short Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends
title_full Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends
title_fullStr Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends
title_full_unstemmed Time Domain Response of Uniform RC Lines With Resistive Termination at Both Ends
title_sort time domain response of uniform rc lines with resistive termination at both ends
publisher Hindawi Limited
series Active and Passive Electronic Components
issn 0882-7516
1563-5031
publishDate 1994-01-01
description The time domain response of uniform RC lines with resistive termination at both ends is obtained by obtaining the approximate poles of the transfer function. A simple model is developed for the URC line. The model consists of three passive elements only and can be easily implemented for computeraided analysis of URC lines with resistive termination at both ends.
url http://dx.doi.org/10.1155/1994/63861
work_keys_str_mv AT muhammadtaherabuelmaatti timedomainresponseofuniformrclineswithresistiveterminationatbothends
_version_ 1725681743952871424