Ship Power System Analysis Based on Safety Aspects

This article analyses the reasons for the reduction of insulating resistance, processes influencing them and isolation diagnostic methods. It provides a short description of electrical safety situation on ships with isolated neutral electrical power systems. It also covers the methods of protecting...

Full description

Bibliographic Details
Main Authors: Urbaha Margarita, Križus Arnis, Kreisberg Deniss
Format: Article
Language:English
Published: Sciendo 2017-08-01
Series:Transport and Aerospace Engineering
Subjects:
Online Access:https://doi.org/10.1515/tae-2017-0012
Description
Summary:This article analyses the reasons for the reduction of insulating resistance, processes influencing them and isolation diagnostic methods. It provides a short description of electrical safety situation on ships with isolated neutral electrical power systems. It also covers the methods of protecting personnel from electric shock or preventing ignition or arching damage at the fault location with the help of fault current compensation. Principal fault current compensation circuit diagrams are analysed by using the minimum value and time of transient fault current as criteria.