Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
AIM: To investigate the differences of the relevant parameters of optic nerve between patients with suspected ocular hypertension and normal people. <p>METHODS: There were 36 eyes of suspected ocular hypertension and 43 normal eyes to test their retinal nerve fiber layer thickness(RNFL), the o...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2014-04-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://www.ies.net.cn/cn_publish/2014/4/201404037.pdf |
id |
doaj-4a7c08fe5dc94cc389253fd84bc37fdf |
---|---|
record_format |
Article |
spelling |
doaj-4a7c08fe5dc94cc389253fd84bc37fdf2020-11-25T00:58:10ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-04-0114470470610.3980/j.issn.1672-5123.2014.04.37Study of the relevant parameters of optic nerve of patients with suspected ocular hypertensionQing-Qing Yao0Dan Liu1Liaoning Medical University, Jinzhou 121001, Liaoning Province, ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Liaoning Medical University, Jinzhou 121001, Liaoning Province, ChinaAIM: To investigate the differences of the relevant parameters of optic nerve between patients with suspected ocular hypertension and normal people. <p>METHODS: There were 36 eyes of suspected ocular hypertension and 43 normal eyes to test their retinal nerve fiber layer thickness(RNFL), the optic disk parameters, the thickness of macular ganglion cell complex(mGCCT)and visual field index. The analysis and comparison are made on the obtained results.<p>RESULTS: There was significant difference(<i>P</i><0.01)between the patients with suspected ocular hypertension and normal eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of macular ganglion cell complex(<i>P</i><0.01). There was statistical difference between two groups in nasal RNFL thickness(<i>P</i><0.05), but there was no statistical difference in temporal RNFL thickness, cup area, mean deviation(MD)and pattern standard deviation(PSD)(<i>P</i>>0.05).<p>CONCLUSION: There is significant difference between normal and suspected ocular hypertension eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of mGCCT.http://www.ies.net.cn/cn_publish/2014/4/201404037.pdfsuspected ocular hypertensionretinal nerve fiber layer thicknessoptic disk parametersmacular ganglion cell complexvisual field indexvisual field index |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Qing-Qing Yao Dan Liu |
spellingShingle |
Qing-Qing Yao Dan Liu Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension Guoji Yanke Zazhi suspected ocular hypertension retinal nerve fiber layer thickness optic disk parameters macular ganglion cell complex visual field index visual field index |
author_facet |
Qing-Qing Yao Dan Liu |
author_sort |
Qing-Qing Yao |
title |
Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension |
title_short |
Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension |
title_full |
Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension |
title_fullStr |
Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension |
title_full_unstemmed |
Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension |
title_sort |
study of the relevant parameters of optic nerve of patients with suspected ocular hypertension |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
Guoji Yanke Zazhi |
issn |
1672-5123 1672-5123 |
publishDate |
2014-04-01 |
description |
AIM: To investigate the differences of the relevant parameters of optic nerve between patients with suspected ocular hypertension and normal people. <p>METHODS: There were 36 eyes of suspected ocular hypertension and 43 normal eyes to test their retinal nerve fiber layer thickness(RNFL), the optic disk parameters, the thickness of macular ganglion cell complex(mGCCT)and visual field index. The analysis and comparison are made on the obtained results.<p>RESULTS: There was significant difference(<i>P</i><0.01)between the patients with suspected ocular hypertension and normal eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of macular ganglion cell complex(<i>P</i><0.01). There was statistical difference between two groups in nasal RNFL thickness(<i>P</i><0.05), but there was no statistical difference in temporal RNFL thickness, cup area, mean deviation(MD)and pattern standard deviation(PSD)(<i>P</i>>0.05).<p>CONCLUSION: There is significant difference between normal and suspected ocular hypertension eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of mGCCT. |
topic |
suspected ocular hypertension retinal nerve fiber layer thickness optic disk parameters macular ganglion cell complex visual field index visual field index |
url |
http://www.ies.net.cn/cn_publish/2014/4/201404037.pdf |
work_keys_str_mv |
AT qingqingyao studyoftherelevantparametersofopticnerveofpatientswithsuspectedocularhypertension AT danliu studyoftherelevantparametersofopticnerveofpatientswithsuspectedocularhypertension |
_version_ |
1725221219989454848 |