Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension

AIM: To investigate the differences of the relevant parameters of optic nerve between patients with suspected ocular hypertension and normal people. <p>METHODS: There were 36 eyes of suspected ocular hypertension and 43 normal eyes to test their retinal nerve fiber layer thickness(RNFL), the o...

Full description

Bibliographic Details
Main Authors: Qing-Qing Yao, Dan Liu
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2014-04-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://www.ies.net.cn/cn_publish/2014/4/201404037.pdf
id doaj-4a7c08fe5dc94cc389253fd84bc37fdf
record_format Article
spelling doaj-4a7c08fe5dc94cc389253fd84bc37fdf2020-11-25T00:58:10ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232014-04-0114470470610.3980/j.issn.1672-5123.2014.04.37Study of the relevant parameters of optic nerve of patients with suspected ocular hypertensionQing-Qing Yao0Dan Liu1Liaoning Medical University, Jinzhou 121001, Liaoning Province, ChinaDepartment of Ophthalmology, the First Affiliated Hospital of Liaoning Medical University, Jinzhou 121001, Liaoning Province, ChinaAIM: To investigate the differences of the relevant parameters of optic nerve between patients with suspected ocular hypertension and normal people. <p>METHODS: There were 36 eyes of suspected ocular hypertension and 43 normal eyes to test their retinal nerve fiber layer thickness(RNFL), the optic disk parameters, the thickness of macular ganglion cell complex(mGCCT)and visual field index. The analysis and comparison are made on the obtained results.<p>RESULTS: There was significant difference(<i>P</i><0.01)between the patients with suspected ocular hypertension and normal eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of macular ganglion cell complex(<i>P</i><0.01). There was statistical difference between two groups in nasal RNFL thickness(<i>P</i><0.05), but there was no statistical difference in temporal RNFL thickness, cup area, mean deviation(MD)and pattern standard deviation(PSD)(<i>P</i>>0.05).<p>CONCLUSION: There is significant difference between normal and suspected ocular hypertension eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of mGCCT.http://www.ies.net.cn/cn_publish/2014/4/201404037.pdfsuspected ocular hypertensionretinal nerve fiber layer thicknessoptic disk parametersmacular ganglion cell complexvisual field indexvisual field index
collection DOAJ
language English
format Article
sources DOAJ
author Qing-Qing Yao
Dan Liu
spellingShingle Qing-Qing Yao
Dan Liu
Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
Guoji Yanke Zazhi
suspected ocular hypertension
retinal nerve fiber layer thickness
optic disk parameters
macular ganglion cell complex
visual field index
visual field index
author_facet Qing-Qing Yao
Dan Liu
author_sort Qing-Qing Yao
title Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
title_short Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
title_full Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
title_fullStr Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
title_full_unstemmed Study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
title_sort study of the relevant parameters of optic nerve of patients with suspected ocular hypertension
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
1672-5123
publishDate 2014-04-01
description AIM: To investigate the differences of the relevant parameters of optic nerve between patients with suspected ocular hypertension and normal people. <p>METHODS: There were 36 eyes of suspected ocular hypertension and 43 normal eyes to test their retinal nerve fiber layer thickness(RNFL), the optic disk parameters, the thickness of macular ganglion cell complex(mGCCT)and visual field index. The analysis and comparison are made on the obtained results.<p>RESULTS: There was significant difference(<i>P</i><0.01)between the patients with suspected ocular hypertension and normal eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of macular ganglion cell complex(<i>P</i><0.01). There was statistical difference between two groups in nasal RNFL thickness(<i>P</i><0.05), but there was no statistical difference in temporal RNFL thickness, cup area, mean deviation(MD)and pattern standard deviation(PSD)(<i>P</i>>0.05).<p>CONCLUSION: There is significant difference between normal and suspected ocular hypertension eyes in average, inferior and superior RNFL thickness, optic disk parameters(rim area, cup volume, average C/D ratio)and the average, inferior, superior thickness of mGCCT.
topic suspected ocular hypertension
retinal nerve fiber layer thickness
optic disk parameters
macular ganglion cell complex
visual field index
visual field index
url http://www.ies.net.cn/cn_publish/2014/4/201404037.pdf
work_keys_str_mv AT qingqingyao studyoftherelevantparametersofopticnerveofpatientswithsuspectedocularhypertension
AT danliu studyoftherelevantparametersofopticnerveofpatientswithsuspectedocularhypertension
_version_ 1725221219989454848