New Technique of Direct Intra-abdominal Pressure Measurement
To determine the efficacy of 14-Fr PVC round drain in the direct measurement of intra-abdominal pressure. Methods: Fifty consecutive patients undergoing elective laparoscopic surgery in a tertiary teaching hospital were included in this pilot study. Patients underwent laparoscopic cholecystectomy, a...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2006-10-01
|
Series: | Asian Journal of Surgery |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S101595840960097X |
id |
doaj-4a3794379cd642b9bffe00b3dfe75070 |
---|---|
record_format |
Article |
spelling |
doaj-4a3794379cd642b9bffe00b3dfe750702020-11-24T22:15:40ZengElsevierAsian Journal of Surgery1015-95842006-10-0129424725010.1016/S1015-9584(09)60097-XNew Technique of Direct Intra-abdominal Pressure MeasurementElena Risin0Boris Kessel1Noah Lieberman2Michael Schmilovich3Itamar Ashkenazi4Ricardo Alfici5Department of Anesthesiology, Hillel Yaffe Medical Center, Hadera, IsraelTrauma Unit, Hillel Yaffe Medical Center, Hadera, IsraelDepartment of Anesthesiology, Hillel Yaffe Medical Center, Hadera, IsraelSurgery B Department, Hillel Yaffe Medical Center, Hadera, IsraelSurgery B Department, Hillel Yaffe Medical Center, Hadera, IsraelSurgery B Department, Hillel Yaffe Medical Center, Hadera, IsraelTo determine the efficacy of 14-Fr PVC round drain in the direct measurement of intra-abdominal pressure. Methods: Fifty consecutive patients undergoing elective laparoscopic surgery in a tertiary teaching hospital were included in this pilot study. Patients underwent laparoscopic cholecystectomy, appendectomy, splenectomy, colectomy and Nissen fundoplication. After creation of pneumoperitoneum and insertion of the trocars as indicated by the operation, a 14-Fr PVC round drain was inserted into the abdominal cavity via one of the laparoscopic ports. It was then connected under sterile conditions to the invasive blood pressure measurement system. Intra-abdominal pressure was gradually increased. Intra-abdominal pressures as measured through the round PVC drain were compared to those measured by the laparoscopic insufflator at 5, 8, 12 and 24 mmHg. Results: Two hundred measurements using each of the two methods were performed and correlated. The correlation coefficient was 0.996. No complications were observed with this new technique. Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.http://www.sciencedirect.com/science/article/pii/S101595840960097Xabdominal compartment syndromeabdominal hypertensiondirect measurementsintra-abdominal pressure monitoringintravesical pressure |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Elena Risin Boris Kessel Noah Lieberman Michael Schmilovich Itamar Ashkenazi Ricardo Alfici |
spellingShingle |
Elena Risin Boris Kessel Noah Lieberman Michael Schmilovich Itamar Ashkenazi Ricardo Alfici New Technique of Direct Intra-abdominal Pressure Measurement Asian Journal of Surgery abdominal compartment syndrome abdominal hypertension direct measurements intra-abdominal pressure monitoring intravesical pressure |
author_facet |
Elena Risin Boris Kessel Noah Lieberman Michael Schmilovich Itamar Ashkenazi Ricardo Alfici |
author_sort |
Elena Risin |
title |
New Technique of Direct Intra-abdominal Pressure Measurement |
title_short |
New Technique of Direct Intra-abdominal Pressure Measurement |
title_full |
New Technique of Direct Intra-abdominal Pressure Measurement |
title_fullStr |
New Technique of Direct Intra-abdominal Pressure Measurement |
title_full_unstemmed |
New Technique of Direct Intra-abdominal Pressure Measurement |
title_sort |
new technique of direct intra-abdominal pressure measurement |
publisher |
Elsevier |
series |
Asian Journal of Surgery |
issn |
1015-9584 |
publishDate |
2006-10-01 |
description |
To determine the efficacy of 14-Fr PVC round drain in the direct measurement of intra-abdominal pressure.
Methods: Fifty consecutive patients undergoing elective laparoscopic surgery in a tertiary teaching hospital were included in this pilot study. Patients underwent laparoscopic cholecystectomy, appendectomy, splenectomy, colectomy and Nissen fundoplication. After creation of pneumoperitoneum and insertion of the trocars as indicated by the operation, a 14-Fr PVC round drain was inserted into the abdominal cavity via one of the laparoscopic ports. It was then connected under sterile conditions to the invasive blood pressure measurement system. Intra-abdominal pressure was gradually increased. Intra-abdominal pressures as measured through the round PVC drain were compared to those measured by the laparoscopic insufflator at 5, 8, 12 and 24 mmHg.
Results: Two hundred measurements using each of the two methods were performed and correlated. The correlation coefficient was 0.996. No complications were observed with this new technique.
Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients. |
topic |
abdominal compartment syndrome abdominal hypertension direct measurements intra-abdominal pressure monitoring intravesical pressure |
url |
http://www.sciencedirect.com/science/article/pii/S101595840960097X |
work_keys_str_mv |
AT elenarisin newtechniqueofdirectintraabdominalpressuremeasurement AT boriskessel newtechniqueofdirectintraabdominalpressuremeasurement AT noahlieberman newtechniqueofdirectintraabdominalpressuremeasurement AT michaelschmilovich newtechniqueofdirectintraabdominalpressuremeasurement AT itamarashkenazi newtechniqueofdirectintraabdominalpressuremeasurement AT ricardoalfici newtechniqueofdirectintraabdominalpressuremeasurement |
_version_ |
1725793859201400832 |