Examining hemodialyzer membrane performance using proteomic technologies

Mario Bonomini,1 Luisa Pieroni,2 Lorenzo Di Liberato,1 Vittorio Sirolli,1 Andrea Urbani2,3 1Department of Medicine, G. d’Annunzio University, Chieti, 2Proteomic and Metabonomic Units, IRCCS S. Lucia Foundation, Rome, 3Faculty of Medicine, Biochemistry and Clinical Biochemistry In...

Full description

Bibliographic Details
Main Authors: Bonomini M, Pieroni L, Di Liberato L, Sirolli V, Urbani A
Format: Article
Language:English
Published: Dove Medical Press 2017-12-01
Series:Therapeutics and Clinical Risk Management
Subjects:
Online Access:https://www.dovepress.com/examining-hemodialyzer-membrane-performance-using-proteomic-technologi-peer-reviewed-article-TCRM
id doaj-4a24856c7ee14e02adacd4b97a1cd5d3
record_format Article
spelling doaj-4a24856c7ee14e02adacd4b97a1cd5d32020-11-24T23:43:10ZengDove Medical PressTherapeutics and Clinical Risk Management1178-203X2017-12-01Volume 141936047Examining hemodialyzer membrane performance using proteomic technologiesBonomini MPieroni LDi Liberato LSirolli VUrbani AMario Bonomini,1 Luisa Pieroni,2 Lorenzo Di Liberato,1 Vittorio Sirolli,1 Andrea Urbani2,3 1Department of Medicine, G. d’Annunzio University, Chieti, 2Proteomic and Metabonomic Units, IRCCS S. Lucia Foundation, Rome, 3Faculty of Medicine, Biochemistry and Clinical Biochemistry Institute, Catholic University of the “Sacred Heart”, Rome, Italy Abstract: The success and the quality of hemodialysis therapy are mainly related to both clearance and biocompatibility properties of the artificial membrane packed in the hemodialyzer. Performance of a membrane is strongly influenced by its interaction with the plasma protein repertoire during the extracorporeal procedure. Recognition that a number of medium–high molecular weight solutes, including proteins and protein-bound molecules, are potentially toxic has prompted the development of more permeable membranes. Such membrane engineering, however, may cause loss of vital proteins, with membrane removal being nonspecific. In addition, plasma proteins can be adsorbed onto the membrane surface upon blood contact during dialysis. Adsorption can contribute to the removal of toxic compounds and governs the biocompatibility of a membrane, since surface-adsorbed proteins may trigger a variety of biologic blood pathways with pathophysiologic consequences. Over the last years, use of proteomic approaches has allowed polypeptide spectrum involved in the process of hemodialysis, a key issue previously hampered by lack of suitable technology, to be assessed in an unbiased manner and in its full complexity. Proteomics has been successfully applied to identify and quantify proteins in complex mixtures such as dialysis outflow fluid and fluid desorbed from dialysis membrane containing adsorbed proteins. The identified proteins can also be characterized by their involvement in metabolic and signaling pathways, molecular networks, and biologic processes through application of bioinformatics tools. Proteomics may thus provide an actual functional definition as to the effect of a membrane material on plasma proteins during hemodialysis. Here, we review the results of proteomic studies on the performance of hemodialysis membranes, as evaluated in terms of solute removal efficiency and blood–membrane interactions. The evidence collected indicates that the information provided by proteomic investigations yields improved molecular and functional knowledge and may lead to the development of more efficient membranes for the potential benefit of the patient. Keywords: mass spectrometry, hemodialysis, end-stage renal disease, protein adsorption, biocompatibility, uremic toxinhttps://www.dovepress.com/examining-hemodialyzer-membrane-performance-using-proteomic-technologi-peer-reviewed-article-TCRMMass SpectrometryHemodialysisMembraneProtein AdsorptionBiocompatibilityUremic Toxin
collection DOAJ
language English
format Article
sources DOAJ
author Bonomini M
Pieroni L
Di Liberato L
Sirolli V
Urbani A
spellingShingle Bonomini M
Pieroni L
Di Liberato L
Sirolli V
Urbani A
Examining hemodialyzer membrane performance using proteomic technologies
Therapeutics and Clinical Risk Management
Mass Spectrometry
Hemodialysis
Membrane
Protein Adsorption
Biocompatibility
Uremic Toxin
author_facet Bonomini M
Pieroni L
Di Liberato L
Sirolli V
Urbani A
author_sort Bonomini M
title Examining hemodialyzer membrane performance using proteomic technologies
title_short Examining hemodialyzer membrane performance using proteomic technologies
title_full Examining hemodialyzer membrane performance using proteomic technologies
title_fullStr Examining hemodialyzer membrane performance using proteomic technologies
title_full_unstemmed Examining hemodialyzer membrane performance using proteomic technologies
title_sort examining hemodialyzer membrane performance using proteomic technologies
publisher Dove Medical Press
series Therapeutics and Clinical Risk Management
issn 1178-203X
publishDate 2017-12-01
description Mario Bonomini,1 Luisa Pieroni,2 Lorenzo Di Liberato,1 Vittorio Sirolli,1 Andrea Urbani2,3 1Department of Medicine, G. d’Annunzio University, Chieti, 2Proteomic and Metabonomic Units, IRCCS S. Lucia Foundation, Rome, 3Faculty of Medicine, Biochemistry and Clinical Biochemistry Institute, Catholic University of the “Sacred Heart”, Rome, Italy Abstract: The success and the quality of hemodialysis therapy are mainly related to both clearance and biocompatibility properties of the artificial membrane packed in the hemodialyzer. Performance of a membrane is strongly influenced by its interaction with the plasma protein repertoire during the extracorporeal procedure. Recognition that a number of medium–high molecular weight solutes, including proteins and protein-bound molecules, are potentially toxic has prompted the development of more permeable membranes. Such membrane engineering, however, may cause loss of vital proteins, with membrane removal being nonspecific. In addition, plasma proteins can be adsorbed onto the membrane surface upon blood contact during dialysis. Adsorption can contribute to the removal of toxic compounds and governs the biocompatibility of a membrane, since surface-adsorbed proteins may trigger a variety of biologic blood pathways with pathophysiologic consequences. Over the last years, use of proteomic approaches has allowed polypeptide spectrum involved in the process of hemodialysis, a key issue previously hampered by lack of suitable technology, to be assessed in an unbiased manner and in its full complexity. Proteomics has been successfully applied to identify and quantify proteins in complex mixtures such as dialysis outflow fluid and fluid desorbed from dialysis membrane containing adsorbed proteins. The identified proteins can also be characterized by their involvement in metabolic and signaling pathways, molecular networks, and biologic processes through application of bioinformatics tools. Proteomics may thus provide an actual functional definition as to the effect of a membrane material on plasma proteins during hemodialysis. Here, we review the results of proteomic studies on the performance of hemodialysis membranes, as evaluated in terms of solute removal efficiency and blood–membrane interactions. The evidence collected indicates that the information provided by proteomic investigations yields improved molecular and functional knowledge and may lead to the development of more efficient membranes for the potential benefit of the patient. Keywords: mass spectrometry, hemodialysis, end-stage renal disease, protein adsorption, biocompatibility, uremic toxin
topic Mass Spectrometry
Hemodialysis
Membrane
Protein Adsorption
Biocompatibility
Uremic Toxin
url https://www.dovepress.com/examining-hemodialyzer-membrane-performance-using-proteomic-technologi-peer-reviewed-article-TCRM
work_keys_str_mv AT bonominim examininghemodialyzermembraneperformanceusingproteomictechnologies
AT pieronil examininghemodialyzermembraneperformanceusingproteomictechnologies
AT diliberatol examininghemodialyzermembraneperformanceusingproteomictechnologies
AT sirolliv examininghemodialyzermembraneperformanceusingproteomictechnologies
AT urbania examininghemodialyzermembraneperformanceusingproteomictechnologies
_version_ 1716281506200027136