HILIC-Enabled <sup>13</sup>C Metabolomics Strategies: Comparing Quantitative Precision and Spectral Accuracy of QTOF High- and QQQ Low-Resolution Mass Spectrometry

Dynamic <sup>13</sup>C-tracer-based flux analyses of in vivo reaction networks still require a continuous development of advanced quantification methods applying state-of-the-art mass spectrometry platforms. Utilizing alkaline HILIC chromatography, we adapt strategies for a systematic qu...

Full description

Bibliographic Details
Main Authors: André Feith, Attila Teleki, Michaela Graf, Lorenzo Favilli, Ralf Takors
Format: Article
Language:English
Published: MDPI AG 2019-04-01
Series:Metabolites
Subjects:
Online Access:https://www.mdpi.com/2218-1989/9/4/63
Description
Summary:Dynamic <sup>13</sup>C-tracer-based flux analyses of in vivo reaction networks still require a continuous development of advanced quantification methods applying state-of-the-art mass spectrometry platforms. Utilizing alkaline HILIC chromatography, we adapt strategies for a systematic quantification study in non- and <sup>13</sup>C-labeled multicomponent endogenous <i>Corynebacterium glutamicum</i> extracts by LC-QTOF high resolution (HRMS) and LC-QQQ tandem mass spectrometry (MS/MS). Without prior derivatization, a representative cross-section of 17 central carbon and anabolic key intermediates were analyzed with high selectivity and sensitivity under optimized ESI-MS settings. In column detection limits for the absolute quantification range were between 6.8&#8211;304.7 (QQQ) and 28.7&#8211;881.5 fmol (QTOF) with comparable linearities (3&#8211;5 orders of magnitude) and enhanced precision using QQQ-MRM detection. Tailor-made preparations of uniformly (U)<sup>13</sup>C-labeled cultivation extracts for isotope dilution mass spectrometry enabled the accurate quantification in complex sample matrices and extended linearities without effect on method parameters. Furthermore, evaluation of metabolite-specific <i>m+1</i>-to-<i>m+0</i> ratios (ISR<sub>1:0</sub>) in non-labeled extracts exhibited sufficient methodical spectral accuracies with mean deviations of 3.89 &#177; 3.54% (QTOF) and 4.01 &#177; 3.01% (QQQ). Based on the excellent HILIC performance, conformity analysis of time-resolved isotopic enrichments in <sup>13</sup>C-tracer experiments revealed sufficient spectral accuracy for QQQ-SIM detection. However, only QTOF-HRMS ensures determination of the full isotopologue space in complex matrices without mass interferences.
ISSN:2218-1989