Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel
The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/13/8/1968 |
id |
doaj-49317111fced47cd8c679cdf7490509d |
---|---|
record_format |
Article |
spelling |
doaj-49317111fced47cd8c679cdf7490509d2020-11-25T03:03:36ZengMDPI AGEnergies1996-10732020-04-01131968196810.3390/en13081968Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka HotelMarek Borowski0Piotr Mazur1Sławosz Kleszcz2Klaudia Zwolińska3Faculty of Mining and Geoengineering, AGH University of Science and Technology, 30-059 Kraków, PolandFrapol Sp. z o.o., 30-832 Kraków, PolandFrapol Sp. z o.o., 30-832 Kraków, PolandFaculty of Mining and Geoengineering, AGH University of Science and Technology, 30-059 Kraków, PolandThe energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades.https://www.mdpi.com/1996-1073/13/8/1968nearly zero-energy buildingsenergy efficiencyventilationheating and cooling systemenergy monitoringsustainable buildings |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Marek Borowski Piotr Mazur Sławosz Kleszcz Klaudia Zwolińska |
spellingShingle |
Marek Borowski Piotr Mazur Sławosz Kleszcz Klaudia Zwolińska Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel Energies nearly zero-energy buildings energy efficiency ventilation heating and cooling system energy monitoring sustainable buildings |
author_facet |
Marek Borowski Piotr Mazur Sławosz Kleszcz Klaudia Zwolińska |
author_sort |
Marek Borowski |
title |
Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel |
title_short |
Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel |
title_full |
Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel |
title_fullStr |
Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel |
title_full_unstemmed |
Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel |
title_sort |
energy monitoring in a heating and cooling system in a building based on the example of the turówka hotel |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2020-04-01 |
description |
The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades. |
topic |
nearly zero-energy buildings energy efficiency ventilation heating and cooling system energy monitoring sustainable buildings |
url |
https://www.mdpi.com/1996-1073/13/8/1968 |
work_keys_str_mv |
AT marekborowski energymonitoringinaheatingandcoolingsysteminabuildingbasedontheexampleoftheturowkahotel AT piotrmazur energymonitoringinaheatingandcoolingsysteminabuildingbasedontheexampleoftheturowkahotel AT sławoszkleszcz energymonitoringinaheatingandcoolingsysteminabuildingbasedontheexampleoftheturowkahotel AT klaudiazwolinska energymonitoringinaheatingandcoolingsysteminabuildingbasedontheexampleoftheturowkahotel |
_version_ |
1724684936284209152 |