Effects of implant threads on the contact area and stress distribution of marginal bone

Stable osseointegration between implant threads and the surrounding marginal bone provides the mechanical base of an implant for daily chewing activity. The contact area of implant-bone interfaces and the concentrated stresses on the marginal bones are principal concerns of implant designers. The pu...

Full description

Bibliographic Details
Main Authors: Chia-Ching Lee, Shang-Chih Lin, Ming-Jen Kang, Shu-Wei Wu, Ping-Yuen Fu
Format: Article
Language:English
Published: Elsevier 2010-09-01
Series:Journal of Dental Sciences
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1991790210600232
id doaj-4921ebfb24d4476b9d32ed112a81a112
record_format Article
spelling doaj-4921ebfb24d4476b9d32ed112a81a1122020-11-24T21:28:58ZengElsevierJournal of Dental Sciences1991-79022010-09-015315616510.1016/S1991-7902(10)60023-2Effects of implant threads on the contact area and stress distribution of marginal boneChia-Ching Lee0Shang-Chih Lin1Ming-Jen Kang2Shu-Wei Wu3Ping-Yuen Fu4Institute of Biomedical Engineering, National Central University, Taoyuan, TaiwanInstitute of Biomedical Engineering, National Central University, Taoyuan, TaiwanInstitute of Biomedical Engineering, National Central University, Taoyuan, TaiwanInstitute of Biomedical Engineering, National Central University, Taoyuan, TaiwanSchool of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, TaiwanStable osseointegration between implant threads and the surrounding marginal bone provides the mechanical base of an implant for daily chewing activity. The contact area of implant-bone interfaces and the concentrated stresses on the marginal bones are principal concerns of implant designers. The purpose of this study was to investigate the effects of thread shape and taper on the initial stability of the implant-bone structure. Materials and methods: The thread design was parameterized by shape and taper. Thread shapes included symmetrical, square, and buttressed. Thread tapers were divided into cylindrical and conical profiles. Nine variations of the thread design were developed to numerically evaluate their geometric and mechanical effects on the marginal bone. Results: Among the three thread shapes with the same pitch, the contact area of the square thread was the highest. Among all implant models, it was found that the site with the greatest stress in the surrounding jaw bone was consistently concentrated at the root radii of the first thread. The maximal stress of the square thread was the least. For the same thread shape and taper, a finer pitch resulted in a remarkable increase in the contact area and a decrease in the peak stress. The contact areas and peak stresses of the conical and cylindrical implants were nearly equal. Conclusion: Taking wall thickness and stress concentrations into consideration, the square thread with a 0.60-mm pitch possessed the optimal contact area and stress values compared to the others.http://www.sciencedirect.com/science/article/pii/S1991790210600232bone stresscontact areadental implantmarginal bone lossthread
collection DOAJ
language English
format Article
sources DOAJ
author Chia-Ching Lee
Shang-Chih Lin
Ming-Jen Kang
Shu-Wei Wu
Ping-Yuen Fu
spellingShingle Chia-Ching Lee
Shang-Chih Lin
Ming-Jen Kang
Shu-Wei Wu
Ping-Yuen Fu
Effects of implant threads on the contact area and stress distribution of marginal bone
Journal of Dental Sciences
bone stress
contact area
dental implant
marginal bone loss
thread
author_facet Chia-Ching Lee
Shang-Chih Lin
Ming-Jen Kang
Shu-Wei Wu
Ping-Yuen Fu
author_sort Chia-Ching Lee
title Effects of implant threads on the contact area and stress distribution of marginal bone
title_short Effects of implant threads on the contact area and stress distribution of marginal bone
title_full Effects of implant threads on the contact area and stress distribution of marginal bone
title_fullStr Effects of implant threads on the contact area and stress distribution of marginal bone
title_full_unstemmed Effects of implant threads on the contact area and stress distribution of marginal bone
title_sort effects of implant threads on the contact area and stress distribution of marginal bone
publisher Elsevier
series Journal of Dental Sciences
issn 1991-7902
publishDate 2010-09-01
description Stable osseointegration between implant threads and the surrounding marginal bone provides the mechanical base of an implant for daily chewing activity. The contact area of implant-bone interfaces and the concentrated stresses on the marginal bones are principal concerns of implant designers. The purpose of this study was to investigate the effects of thread shape and taper on the initial stability of the implant-bone structure. Materials and methods: The thread design was parameterized by shape and taper. Thread shapes included symmetrical, square, and buttressed. Thread tapers were divided into cylindrical and conical profiles. Nine variations of the thread design were developed to numerically evaluate their geometric and mechanical effects on the marginal bone. Results: Among the three thread shapes with the same pitch, the contact area of the square thread was the highest. Among all implant models, it was found that the site with the greatest stress in the surrounding jaw bone was consistently concentrated at the root radii of the first thread. The maximal stress of the square thread was the least. For the same thread shape and taper, a finer pitch resulted in a remarkable increase in the contact area and a decrease in the peak stress. The contact areas and peak stresses of the conical and cylindrical implants were nearly equal. Conclusion: Taking wall thickness and stress concentrations into consideration, the square thread with a 0.60-mm pitch possessed the optimal contact area and stress values compared to the others.
topic bone stress
contact area
dental implant
marginal bone loss
thread
url http://www.sciencedirect.com/science/article/pii/S1991790210600232
work_keys_str_mv AT chiachinglee effectsofimplantthreadsonthecontactareaandstressdistributionofmarginalbone
AT shangchihlin effectsofimplantthreadsonthecontactareaandstressdistributionofmarginalbone
AT mingjenkang effectsofimplantthreadsonthecontactareaandstressdistributionofmarginalbone
AT shuweiwu effectsofimplantthreadsonthecontactareaandstressdistributionofmarginalbone
AT pingyuenfu effectsofimplantthreadsonthecontactareaandstressdistributionofmarginalbone
_version_ 1725968147216859136