Control of droplet size in rain-zone in wet cooling tower
The performance of the wet cooling tower is significantly affected by the droplet size occurring in the rain zone. In order to effectively manage the size of these droplets, it was necessary to experimentally determine the effect of the fills of the cooling towers on droplets. Five types of cooling...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | EPJ Web of Conferences |
Online Access: | https://www.epj-conferences.org/articles/epjconf/pdf/2018/15/epjconf_efm2018_02119.pdf |
id |
doaj-49205c06966344f5ba1af4cc0e9c9807 |
---|---|
record_format |
Article |
spelling |
doaj-49205c06966344f5ba1af4cc0e9c98072021-08-02T14:44:07ZengEDP SciencesEPJ Web of Conferences2100-014X2018-01-011800211910.1051/epjconf/201818002119epjconf_efm2018_02119Control of droplet size in rain-zone in wet cooling towerVitkovicova RutVitkovic PavolThe performance of the wet cooling tower is significantly affected by the droplet size occurring in the rain zone. In order to effectively manage the size of these droplets, it was necessary to experimentally determine the effect of the fills of the cooling towers on droplets. Five types of cooling fillers were used for experimental measurements: 3 film fills and 2 splash fills - trickle and grid. Drop size measurements were performed using the LIF method. Histograms of droplets size were obtained from measured droplet sizes under each fill, and for each fill, the Sauter droplet diameter was then calculated. According to a theoretical analysis of a breakdown of droplets, the combinations of some fills and the effect of their surface treatment on the droplet diameter were then measured for comparison.https://www.epj-conferences.org/articles/epjconf/pdf/2018/15/epjconf_efm2018_02119.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Vitkovicova Rut Vitkovic Pavol |
spellingShingle |
Vitkovicova Rut Vitkovic Pavol Control of droplet size in rain-zone in wet cooling tower EPJ Web of Conferences |
author_facet |
Vitkovicova Rut Vitkovic Pavol |
author_sort |
Vitkovicova Rut |
title |
Control of droplet size in rain-zone in wet cooling tower |
title_short |
Control of droplet size in rain-zone in wet cooling tower |
title_full |
Control of droplet size in rain-zone in wet cooling tower |
title_fullStr |
Control of droplet size in rain-zone in wet cooling tower |
title_full_unstemmed |
Control of droplet size in rain-zone in wet cooling tower |
title_sort |
control of droplet size in rain-zone in wet cooling tower |
publisher |
EDP Sciences |
series |
EPJ Web of Conferences |
issn |
2100-014X |
publishDate |
2018-01-01 |
description |
The performance of the wet cooling tower is significantly affected by the droplet size occurring in the rain zone. In order to effectively manage the size of these droplets, it was necessary to experimentally determine the effect of the fills of the cooling towers on droplets. Five types of cooling fillers were used for experimental measurements: 3 film fills and 2 splash fills - trickle and grid. Drop size measurements were performed using the LIF method. Histograms of droplets size were obtained from measured droplet sizes under each fill, and for each fill, the Sauter droplet diameter was then calculated. According to a theoretical analysis of a breakdown of droplets, the combinations of some fills and the effect of their surface treatment on the droplet diameter were then measured for comparison. |
url |
https://www.epj-conferences.org/articles/epjconf/pdf/2018/15/epjconf_efm2018_02119.pdf |
work_keys_str_mv |
AT vitkovicovarut controlofdropletsizeinrainzoneinwetcoolingtower AT vitkovicpavol controlofdropletsizeinrainzoneinwetcoolingtower |
_version_ |
1721231022185512960 |