Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹
This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complex...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Ciência do Solo
2011-08-01
|
Series: | Revista Brasileira de Ciência do Solo |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-06832011000400027&lng=en&tlng=en |
id |
doaj-48ffde79f8634e4e9aeb5dbb36ce45e5 |
---|---|
record_format |
Article |
spelling |
doaj-48ffde79f8634e4e9aeb5dbb36ce45e52021-01-02T00:00:56ZengSociedade Brasileira de Ciência do SoloRevista Brasileira de Ciência do Solo1806-96572011-08-013541331133610.1590/S0100-06832011000400027S0100-06832011000400027Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹Claudia Mara PereiraCristhiane Anete Neiverth0Shizuo MaedaMarcela GuiotokuLuziane FrancisconUniversidade de São PauloThis study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC).http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-06832011000400027&lng=en&tlng=eneletrodo íon seletivotitulador automáticopotenciometria |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Claudia Mara Pereira Cristhiane Anete Neiverth Shizuo Maeda Marcela Guiotoku Luziane Franciscon |
spellingShingle |
Claudia Mara Pereira Cristhiane Anete Neiverth Shizuo Maeda Marcela Guiotoku Luziane Franciscon Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ Revista Brasileira de Ciência do Solo eletrodo íon seletivo titulador automático potenciometria |
author_facet |
Claudia Mara Pereira Cristhiane Anete Neiverth Shizuo Maeda Marcela Guiotoku Luziane Franciscon |
author_sort |
Claudia Mara Pereira |
title |
Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ |
title_short |
Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ |
title_full |
Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ |
title_fullStr |
Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ |
title_full_unstemmed |
Complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ |
title_sort |
complexometric titration with potenciometric indicator to determination of calcium and magnesium in soil extracts¹ |
publisher |
Sociedade Brasileira de Ciência do Solo |
series |
Revista Brasileira de Ciência do Solo |
issn |
1806-9657 |
publishDate |
2011-08-01 |
description |
This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC). |
topic |
eletrodo íon seletivo titulador automático potenciometria |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-06832011000400027&lng=en&tlng=en |
work_keys_str_mv |
AT claudiamarapereira complexometrictitrationwithpotenciometricindicatortodeterminationofcalciumandmagnesiuminsoilextracts1 AT cristhianeaneteneiverth complexometrictitrationwithpotenciometricindicatortodeterminationofcalciumandmagnesiuminsoilextracts1 AT shizuomaeda complexometrictitrationwithpotenciometricindicatortodeterminationofcalciumandmagnesiuminsoilextracts1 AT marcelaguiotoku complexometrictitrationwithpotenciometricindicatortodeterminationofcalciumandmagnesiuminsoilextracts1 AT luzianefranciscon complexometrictitrationwithpotenciometricindicatortodeterminationofcalciumandmagnesiuminsoilextracts1 |
_version_ |
1724364205320044544 |